To evaluate repaired rotator cuff morphologically and quantitatively in one GRAPPATINI MRI examination.

IF 1.1 4区 医学 Q3 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
Yuxue Xie, Jiajie Cai, Qing Li, Tobias Kober, Tom Hilbert, Shuang Chen, Hongyue Tao
{"title":"To evaluate repaired rotator cuff morphologically and quantitatively in one GRAPPATINI MRI examination.","authors":"Yuxue Xie, Jiajie Cai, Qing Li, Tobias Kober, Tom Hilbert, Shuang Chen, Hongyue Tao","doi":"10.1177/02841851241309005","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>GRAPPATINI is capable of originating synthetic T2 images (T2<sub>synth</sub>) and T2 maps in one magnetic resonance imaging (MRI) scan.</p><p><strong>Purpose: </strong>To evaluate GRAPPATINI's performance in providing simultaneous morphological assessment of repaired rotator cuffs (RC) using T2<sub>synth</sub> images and quantitative evaluation of the postoperative clinical outcomes on T2 maps.</p><p><strong>Material and methods: </strong>A total of 45 individuals after repair surgery for at least 2 years were prospectively examined with GRAPPATINI MRI. Clinical scores were also collected. Image quality was measured using contrast-to-noise ratio (CNR) of the repaired tendons on the T2<sub>synth</sub> and compared to conventional T2-weighted (T2W) images. Two blinded readers independently graded the repaired RCs based on the Sugaya classification on both T2<sub>synth</sub> and T2W images to calculate intra- and inter-rater agreements. In addition, T2 values of repaired RCs from the T2 maps generated by GRAPPATINI were correlated with clinical scores.</p><p><strong>Results: </strong>GRAPPATINI successfully provided both synthetic T2W and quantitative T2 map in a clinically feasible acquisition time of 2:18 min for the shoulder. There were no significant differences in mean CNR (<i>P </i>= 0.9) between conventional T2W and T2<sub>synth</sub> images<sub>.</sub> The inter-rater agreement for the Sugaya classification did not differ significantly between T2W and T2<sub>synth</sub> images (<i>P </i>= 0.8). Furthermore, T2 values of the attached RC showed significant correlations with functional outcomes (r = 0.39-0.52; <i>P </i>< 0.05).</p><p><strong>Conclusion: </strong>This study concludes that GRAPPATINI offers a comprehensive assessment of the shoulder by providing both morphological and quantitative evaluations in a single scan. It is an efficient tool for assessing repair status and predicting functional outcomes in patients after arthroscopic RC repair.</p>","PeriodicalId":7143,"journal":{"name":"Acta radiologica","volume":" ","pages":"2841851241309005"},"PeriodicalIF":1.1000,"publicationDate":"2025-02-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Acta radiologica","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1177/02841851241309005","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

Abstract

Background: GRAPPATINI is capable of originating synthetic T2 images (T2synth) and T2 maps in one magnetic resonance imaging (MRI) scan.

Purpose: To evaluate GRAPPATINI's performance in providing simultaneous morphological assessment of repaired rotator cuffs (RC) using T2synth images and quantitative evaluation of the postoperative clinical outcomes on T2 maps.

Material and methods: A total of 45 individuals after repair surgery for at least 2 years were prospectively examined with GRAPPATINI MRI. Clinical scores were also collected. Image quality was measured using contrast-to-noise ratio (CNR) of the repaired tendons on the T2synth and compared to conventional T2-weighted (T2W) images. Two blinded readers independently graded the repaired RCs based on the Sugaya classification on both T2synth and T2W images to calculate intra- and inter-rater agreements. In addition, T2 values of repaired RCs from the T2 maps generated by GRAPPATINI were correlated with clinical scores.

Results: GRAPPATINI successfully provided both synthetic T2W and quantitative T2 map in a clinically feasible acquisition time of 2:18 min for the shoulder. There were no significant differences in mean CNR (P = 0.9) between conventional T2W and T2synth images. The inter-rater agreement for the Sugaya classification did not differ significantly between T2W and T2synth images (P = 0.8). Furthermore, T2 values of the attached RC showed significant correlations with functional outcomes (r = 0.39-0.52; P < 0.05).

Conclusion: This study concludes that GRAPPATINI offers a comprehensive assessment of the shoulder by providing both morphological and quantitative evaluations in a single scan. It is an efficient tool for assessing repair status and predicting functional outcomes in patients after arthroscopic RC repair.

求助全文
约1分钟内获得全文 求助全文
来源期刊
Acta radiologica
Acta radiologica 医学-核医学
CiteScore
2.70
自引率
0.00%
发文量
170
审稿时长
3-8 weeks
期刊介绍: Acta Radiologica publishes articles on all aspects of radiology, from clinical radiology to experimental work. It is known for articles based on experimental work and contrast media research, giving priority to scientific original papers. The distinguished international editorial board also invite review articles, short communications and technical and instrumental notes.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信