Finite element stress analysis to evaluate and compare the effect of splinting in periodontally compromised teeth having 55 % bone loss with different materials

Q1 Medicine
Shivangi Joshi, Prakash Talreja, Prajakta Rao, Nilesh Joshi, Vinayak Thorat, Ruhi Mohta
{"title":"Finite element stress analysis to evaluate and compare the effect of splinting in periodontally compromised teeth having 55 % bone loss with different materials","authors":"Shivangi Joshi,&nbsp;Prakash Talreja,&nbsp;Prajakta Rao,&nbsp;Nilesh Joshi,&nbsp;Vinayak Thorat,&nbsp;Ruhi Mohta","doi":"10.1016/j.jobcr.2025.01.011","DOIUrl":null,"url":null,"abstract":"<div><h3>Background</h3><div>Splinting is commonly employed to stabilize periodontally compromised teeth, but the choice of splint material significantly influences stress distribution within the periodontal ligament (PDL) and surrounding bone. This study aimed to evaluate and compare the stress distribution of four different splint materials—composite, fiber-reinforced composite (FRC), polyetheretherketone (PEEK), and metal—on mandibular anterior teeth with 55 % bone loss using finite element analysis (FEA).</div></div><div><h3>Methodology</h3><div>Finite element models of mandibular anterior teeth with 55 % bone loss were developed using SOLIDWORKS 2020. Simulations were conducted for non-splinted teeth and for teeth splinted with composite, FRC, PEEK, and metal. Stress analysis was performed in ANSYS software under vertical (100N at 0°) and oblique (100N at 45°) loading conditions. Von Mises stress values in the PDL and cortical bone were recorded and statistically analyzed using MedCalc software to compare the performance of different splint materials.</div></div><div><h3>Results</h3><div>Non-splinted teeth exhibited the highest stress levels, particularly under oblique loading conditions. Among the splinting materials, FRC showed the most effective reduction in stress across all teeth, especially under vertical loads. Composite and metal wire splints provided moderate stress reduction, with performance varying depending on the load angle. PEEK splints demonstrated good stress reduction under vertical loads but showed increased stress levels under oblique forces. These results underscore the influence of splint material and load direction on stress distribution in periodontally compromised teeth.</div></div><div><h3>Conclusion</h3><div>The study highlights the critical role of splint material in reducing stress on the PDL of periodontally compromised teeth. FRC splints emerged as the most effective material for minimizing stress under both vertical and oblique loading conditions. Composite and metal wire splints offered moderate efficacy, while PEEK splints were less effective under oblique loads. These findings provide valuable insights for clinicians in selecting optimal splint materials for periodontal stabilization.</div></div>","PeriodicalId":16609,"journal":{"name":"Journal of oral biology and craniofacial research","volume":"15 2","pages":"Pages 250-255"},"PeriodicalIF":0.0000,"publicationDate":"2025-02-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of oral biology and craniofacial research","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2212426825000132","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

Abstract

Background

Splinting is commonly employed to stabilize periodontally compromised teeth, but the choice of splint material significantly influences stress distribution within the periodontal ligament (PDL) and surrounding bone. This study aimed to evaluate and compare the stress distribution of four different splint materials—composite, fiber-reinforced composite (FRC), polyetheretherketone (PEEK), and metal—on mandibular anterior teeth with 55 % bone loss using finite element analysis (FEA).

Methodology

Finite element models of mandibular anterior teeth with 55 % bone loss were developed using SOLIDWORKS 2020. Simulations were conducted for non-splinted teeth and for teeth splinted with composite, FRC, PEEK, and metal. Stress analysis was performed in ANSYS software under vertical (100N at 0°) and oblique (100N at 45°) loading conditions. Von Mises stress values in the PDL and cortical bone were recorded and statistically analyzed using MedCalc software to compare the performance of different splint materials.

Results

Non-splinted teeth exhibited the highest stress levels, particularly under oblique loading conditions. Among the splinting materials, FRC showed the most effective reduction in stress across all teeth, especially under vertical loads. Composite and metal wire splints provided moderate stress reduction, with performance varying depending on the load angle. PEEK splints demonstrated good stress reduction under vertical loads but showed increased stress levels under oblique forces. These results underscore the influence of splint material and load direction on stress distribution in periodontally compromised teeth.

Conclusion

The study highlights the critical role of splint material in reducing stress on the PDL of periodontally compromised teeth. FRC splints emerged as the most effective material for minimizing stress under both vertical and oblique loading conditions. Composite and metal wire splints offered moderate efficacy, while PEEK splints were less effective under oblique loads. These findings provide valuable insights for clinicians in selecting optimal splint materials for periodontal stabilization.
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
4.90
自引率
0.00%
发文量
133
审稿时长
167 days
期刊介绍: Journal of Oral Biology and Craniofacial Research (JOBCR)is the official journal of the Craniofacial Research Foundation (CRF). The journal aims to provide a common platform for both clinical and translational research and to promote interdisciplinary sciences in craniofacial region. JOBCR publishes content that includes diseases, injuries and defects in the head, neck, face, jaws and the hard and soft tissues of the mouth and jaws and face region; diagnosis and medical management of diseases specific to the orofacial tissues and of oral manifestations of systemic diseases; studies on identifying populations at risk of oral disease or in need of specific care, and comparing regional, environmental, social, and access similarities and differences in dental care between populations; diseases of the mouth and related structures like salivary glands, temporomandibular joints, facial muscles and perioral skin; biomedical engineering, tissue engineering and stem cells. The journal publishes reviews, commentaries, peer-reviewed original research articles, short communication, and case reports.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信