Universal, Sensitive, and Visual Sandwich-type Biosensor Based on Nanogold-catalyzed Reduction and its Application for Detecting C-Reactive Protein in Serum by a Portable Colorimeter

IF 8 1区 化学 Q1 CHEMISTRY, ANALYTICAL
Runhui Zhang, Huaze Shao, Xiumei Hu, Yongshi Liang, Hanren Chen, Shiquan Zheng, Lihong Liu
{"title":"Universal, Sensitive, and Visual Sandwich-type Biosensor Based on Nanogold-catalyzed Reduction and its Application for Detecting C-Reactive Protein in Serum by a Portable Colorimeter","authors":"Runhui Zhang, Huaze Shao, Xiumei Hu, Yongshi Liang, Hanren Chen, Shiquan Zheng, Lihong Liu","doi":"10.1016/j.snb.2025.137408","DOIUrl":null,"url":null,"abstract":"We proposed a low-cost, high sensitive and universal point-of-care testing method of different dimension biomarkers based on the target-mediated catalytic reduction suppression of double-sequence aptamers-modified gold nanoparticles (dsApts@AuNPs) and NaBH<sub>4</sub> on the organic dyes (T-AAND). Herein, carcinoembryonic antigen, alpha-fetoprotein, C-reactive protein (CRP), thrombin, lipopolysaccharide, <em>Staphylococcus aureus</em>, and <em>Escherichia coli</em> were chosen as model biomarkers and all successfully detected, with limit of detections of 6.5<!-- --> <!-- -->pg/mL, 12.7<!-- --> <!-- -->pg/mL, 79.7<!-- --> <!-- -->pg/mL, 34.2 fM, 459 fM, 718 CFU/mL, and 830 CFU/mL, respectively. Remarkably, the assay is completed in a single EP tube within 40<!-- --> <!-- -->minutes, with on-site quantification performed using a $70 portable colorimeter and the cost of reagents for each test is $0.75. The CRP levels of 31 patients and 11 healthy volunteers achieved with the latex-enhanced immunoturbidimetry were high consistency with those of the spectrophotometry (<em>r</em> = 0.9964) and the colorimeter (<em>r</em> = 0.9619), demonstrating the accuracy of the new method. In conclusion, the T-AAND integrated a colorimeter is a superior approach for detecting biomarkers, especially in resource-limited settings.","PeriodicalId":425,"journal":{"name":"Sensors and Actuators B: Chemical","volume":"31 1","pages":""},"PeriodicalIF":8.0000,"publicationDate":"2025-02-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Sensors and Actuators B: Chemical","FirstCategoryId":"92","ListUrlMain":"https://doi.org/10.1016/j.snb.2025.137408","RegionNum":1,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0

Abstract

We proposed a low-cost, high sensitive and universal point-of-care testing method of different dimension biomarkers based on the target-mediated catalytic reduction suppression of double-sequence aptamers-modified gold nanoparticles (dsApts@AuNPs) and NaBH4 on the organic dyes (T-AAND). Herein, carcinoembryonic antigen, alpha-fetoprotein, C-reactive protein (CRP), thrombin, lipopolysaccharide, Staphylococcus aureus, and Escherichia coli were chosen as model biomarkers and all successfully detected, with limit of detections of 6.5 pg/mL, 12.7 pg/mL, 79.7 pg/mL, 34.2 fM, 459 fM, 718 CFU/mL, and 830 CFU/mL, respectively. Remarkably, the assay is completed in a single EP tube within 40 minutes, with on-site quantification performed using a $70 portable colorimeter and the cost of reagents for each test is $0.75. The CRP levels of 31 patients and 11 healthy volunteers achieved with the latex-enhanced immunoturbidimetry were high consistency with those of the spectrophotometry (r = 0.9964) and the colorimeter (r = 0.9619), demonstrating the accuracy of the new method. In conclusion, the T-AAND integrated a colorimeter is a superior approach for detecting biomarkers, especially in resource-limited settings.
求助全文
约1分钟内获得全文 求助全文
来源期刊
Sensors and Actuators B: Chemical
Sensors and Actuators B: Chemical 工程技术-电化学
CiteScore
14.60
自引率
11.90%
发文量
1776
审稿时长
3.2 months
期刊介绍: Sensors & Actuators, B: Chemical is an international journal focused on the research and development of chemical transducers. It covers chemical sensors and biosensors, chemical actuators, and analytical microsystems. The journal is interdisciplinary, aiming to publish original works showcasing substantial advancements beyond the current state of the art in these fields, with practical applicability to solving meaningful analytical problems. Review articles are accepted by invitation from an Editor of the journal.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信