Mean Systemic Filling Pressure Trends in Liver Transplant Recipients: An Observational Pilot Study.

IF 0.7 4区 医学 Q4 TRANSPLANTATION
Karthik Ponnappan Thirumurugan, Udit Dhingra, Anil Yogendra Yadav, Amal Francis Sam, Viniyendra Pamecha
{"title":"Mean Systemic Filling Pressure Trends in Liver Transplant Recipients: An Observational Pilot Study.","authors":"Karthik Ponnappan Thirumurugan, Udit Dhingra, Anil Yogendra Yadav, Amal Francis Sam, Viniyendra Pamecha","doi":"10.6002/ect.2024.0183","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>Mean systemic filling pressure is a key determinant of venous return and cardiovascular function, with potential implications for hemodynamic stability in surgical interventions, such as liver transplantation. In this prospective observational pilot study, we investigated changes in mean systemic filling pressure in patients undergoing living related donor liver transplant (primary outcome) and its correlation with various hemodynamic and intraoperative parameters (secondary outcomes).</p><p><strong>Materials and methods: </strong>This study was conducted at a tertiary care hospital between May 2020 and October 2020. We obtained 193 mean systemic filling pressure values from 20 adult patients (aged 18-65 y) undergoing living related donor liver transplant. We analyzed mean systemic filling pressure, heart rate, central venous pressure, mean arterial pressure, cardiac output, systemic vascular resistance, and stroke volume variation measured at baseline and during surgery. Mean systemic filling pressure was assessed by using the arm technique.</p><p><strong>Results: </strong>The baseline mean systemic filling pressure was 35.7 ± 8.6 mm Hg. During dissection (n = 114 mean systemic filling pressure results), anhepatic (n = 39 results), and neo-hepatic (n = 40 results) phases, mean systemic filling pressure was 31.1 ± 8.3, 26.7 ± 5.8, and 27.9 ± 6.1 mm Hg, respectively (P = .002). Among the hemodynamic variables, mean systemic filling pressure was positively correlated with central venous pressure (r = 0.69, P = .001) and negatively correlated with cardiac output (r = -0.53, P = .015).</p><p><strong>Conclusions: </strong>Mean systemic filling pressure values tended to decrease during the anhepatic phase and increase during the neo-hepatic phase. Although we observed strong positive correlation between mean systemic filling pressure and central venous pressure throughout surgery,the expected positive correlation between mean systemic filling pressure and cardiac output was not observed.</p>","PeriodicalId":50467,"journal":{"name":"Experimental and Clinical Transplantation","volume":"23 1","pages":"43-51"},"PeriodicalIF":0.7000,"publicationDate":"2025-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Experimental and Clinical Transplantation","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.6002/ect.2024.0183","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"TRANSPLANTATION","Score":null,"Total":0}
引用次数: 0

Abstract

Objectives: Mean systemic filling pressure is a key determinant of venous return and cardiovascular function, with potential implications for hemodynamic stability in surgical interventions, such as liver transplantation. In this prospective observational pilot study, we investigated changes in mean systemic filling pressure in patients undergoing living related donor liver transplant (primary outcome) and its correlation with various hemodynamic and intraoperative parameters (secondary outcomes).

Materials and methods: This study was conducted at a tertiary care hospital between May 2020 and October 2020. We obtained 193 mean systemic filling pressure values from 20 adult patients (aged 18-65 y) undergoing living related donor liver transplant. We analyzed mean systemic filling pressure, heart rate, central venous pressure, mean arterial pressure, cardiac output, systemic vascular resistance, and stroke volume variation measured at baseline and during surgery. Mean systemic filling pressure was assessed by using the arm technique.

Results: The baseline mean systemic filling pressure was 35.7 ± 8.6 mm Hg. During dissection (n = 114 mean systemic filling pressure results), anhepatic (n = 39 results), and neo-hepatic (n = 40 results) phases, mean systemic filling pressure was 31.1 ± 8.3, 26.7 ± 5.8, and 27.9 ± 6.1 mm Hg, respectively (P = .002). Among the hemodynamic variables, mean systemic filling pressure was positively correlated with central venous pressure (r = 0.69, P = .001) and negatively correlated with cardiac output (r = -0.53, P = .015).

Conclusions: Mean systemic filling pressure values tended to decrease during the anhepatic phase and increase during the neo-hepatic phase. Although we observed strong positive correlation between mean systemic filling pressure and central venous pressure throughout surgery,the expected positive correlation between mean systemic filling pressure and cardiac output was not observed.

求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
1.40
自引率
11.10%
发文量
258
审稿时长
6-12 weeks
期刊介绍: The scope of the journal includes the following: Surgical techniques, innovations, and novelties; Immunobiology and immunosuppression; Clinical results; Complications; Infection; Malignancies; Organ donation; Organ and tissue procurement and preservation; Sociological and ethical issues; Xenotransplantation.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信