Early radiographic evaluation of an anatomic porous tantalum tibia: A prospective, multi-center, non-randomized clinical study

IF 1.6 4区 医学 Q3 ORTHOPEDICS
Knee Pub Date : 2025-02-07 DOI:10.1016/j.knee.2025.01.010
Cass Nakasone , Ian Weber , Craig Israelite , Jason Cholewa
{"title":"Early radiographic evaluation of an anatomic porous tantalum tibia: A prospective, multi-center, non-randomized clinical study","authors":"Cass Nakasone ,&nbsp;Ian Weber ,&nbsp;Craig Israelite ,&nbsp;Jason Cholewa","doi":"10.1016/j.knee.2025.01.010","DOIUrl":null,"url":null,"abstract":"<div><h3>Background</h3><div>Excellent survival rates have been reported for total knee arthroplasty (TKA) performed with cementless porous metal tibial components. More data, however, is necessary to assess the survival and radiographic results of modular implants with anatomic designs. The purpose of this study was to investigate the early radiographic, survival, and clinical outcomes of a cementless tantalum metal tibial implant with a modular anatomic component.</div></div><div><h3>Methods</h3><div>An early follow-up of a prospective, multi-center, non-randomized outcomes study of patients who received cementless tibial implants in primary TKA between 2018 and 2020 was performed. A total of 148 implants were available for review. Radiographs, the Forgotten Joint Score (FJS-12), Oxford Knee Score (OKS), patient satisfaction, and adverse events were collected for at least two-years post-operative. A minimum of two-years follow-up was available for 119 patients and evaluated for progressive radiolucent lines (RLLs).</div></div><div><h3>Results</h3><div>The mean follow-up was 2.2 ± 0.6 years, and the two-year implant survival rate was 98.59% (95% C.I.: 94.46, 99.64) with no aseptic revisions during the follow-up period. Progressive tibial RLLs were present in 3.4% of patients at two-years follow-up, but were all less than 2 mm with all combined RLLs less than 4 mm. The FJS-12 and OKS all significantly (p &lt; 0.0001) increased and exceeded their respective minimal clinical important differences, and 93% of patients were satisfied at two-years follow-up.</div></div><div><h3>Conclusion</h3><div>This study supports excellent survivorship, clinical and patient reported outcomes using cementless, fixed bearing TKA with minimal complications at early follow-up. Further follow-up is necessary to confirm the sustainability of the clinical outcomes and to evaluate mid- to long-term survivorship.</div></div>","PeriodicalId":56110,"journal":{"name":"Knee","volume":"53 ","pages":"Pages 264-272"},"PeriodicalIF":1.6000,"publicationDate":"2025-02-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Knee","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0968016025000110","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
引用次数: 0

Abstract

Background

Excellent survival rates have been reported for total knee arthroplasty (TKA) performed with cementless porous metal tibial components. More data, however, is necessary to assess the survival and radiographic results of modular implants with anatomic designs. The purpose of this study was to investigate the early radiographic, survival, and clinical outcomes of a cementless tantalum metal tibial implant with a modular anatomic component.

Methods

An early follow-up of a prospective, multi-center, non-randomized outcomes study of patients who received cementless tibial implants in primary TKA between 2018 and 2020 was performed. A total of 148 implants were available for review. Radiographs, the Forgotten Joint Score (FJS-12), Oxford Knee Score (OKS), patient satisfaction, and adverse events were collected for at least two-years post-operative. A minimum of two-years follow-up was available for 119 patients and evaluated for progressive radiolucent lines (RLLs).

Results

The mean follow-up was 2.2 ± 0.6 years, and the two-year implant survival rate was 98.59% (95% C.I.: 94.46, 99.64) with no aseptic revisions during the follow-up period. Progressive tibial RLLs were present in 3.4% of patients at two-years follow-up, but were all less than 2 mm with all combined RLLs less than 4 mm. The FJS-12 and OKS all significantly (p < 0.0001) increased and exceeded their respective minimal clinical important differences, and 93% of patients were satisfied at two-years follow-up.

Conclusion

This study supports excellent survivorship, clinical and patient reported outcomes using cementless, fixed bearing TKA with minimal complications at early follow-up. Further follow-up is necessary to confirm the sustainability of the clinical outcomes and to evaluate mid- to long-term survivorship.
求助全文
约1分钟内获得全文 求助全文
来源期刊
Knee
Knee 医学-外科
CiteScore
3.80
自引率
5.30%
发文量
171
审稿时长
6 months
期刊介绍: The Knee is an international journal publishing studies on the clinical treatment and fundamental biomechanical characteristics of this joint. The aim of the journal is to provide a vehicle relevant to surgeons, biomedical engineers, imaging specialists, materials scientists, rehabilitation personnel and all those with an interest in the knee. The topics covered include, but are not limited to: • Anatomy, physiology, morphology and biochemistry; • Biomechanical studies; • Advances in the development of prosthetic, orthotic and augmentation devices; • Imaging and diagnostic techniques; • Pathology; • Trauma; • Surgery; • Rehabilitation.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信