Evaluation of a high-resolution gas chromatography/high-resolution mass spectrometry method for the determination of 2,3,7,8-tetrachlorodibenzo-p-dioxin in soil and water.

J S Stanley, T M Sack, Y Tondeur, W F Beckert
{"title":"Evaluation of a high-resolution gas chromatography/high-resolution mass spectrometry method for the determination of 2,3,7,8-tetrachlorodibenzo-p-dioxin in soil and water.","authors":"J S Stanley,&nbsp;T M Sack,&nbsp;Y Tondeur,&nbsp;W F Beckert","doi":"10.1002/bms.1200170108","DOIUrl":null,"url":null,"abstract":"<p><p>An analytical protocol for the determination of 2,3,7,8-tetrachlorodibenzo-p-dioxin (2,3,7,8-TCDD) and total TCDDs in soil, sediment, and aqueous samples using high-resolution gas chromatography/high-resolution mass spectrometry (HRGC/HRMS) was evaluated through replicate analyses of fortified and unspiked soil and aqueous samples. The results of these analyses demonstrated that the method is useful for the determination of 2,3,7,8-TCDD and total TCDDs at concentrations ranging from 10 to 200 pg/g (ppt) in soil samples and from 100 to 2000 pg/l (ppq) in aqueous samples. Absolute recoveries of the method internal standard, (13C12-2,3,7,8-TCDD, ranged from 24 to 88%. Lower levels of detection can be achieved through a slight modification of the method with respect to initial sample size and/or final extract volume. Instrumental parameters that affect data quality, specifically HRGC column performance, mass resolution and mass measurement accuracy are presented.</p>","PeriodicalId":8924,"journal":{"name":"Biomedical & environmental mass spectrometry","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"1988-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1002/bms.1200170108","citationCount":"8","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Biomedical & environmental mass spectrometry","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1002/bms.1200170108","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 8

Abstract

An analytical protocol for the determination of 2,3,7,8-tetrachlorodibenzo-p-dioxin (2,3,7,8-TCDD) and total TCDDs in soil, sediment, and aqueous samples using high-resolution gas chromatography/high-resolution mass spectrometry (HRGC/HRMS) was evaluated through replicate analyses of fortified and unspiked soil and aqueous samples. The results of these analyses demonstrated that the method is useful for the determination of 2,3,7,8-TCDD and total TCDDs at concentrations ranging from 10 to 200 pg/g (ppt) in soil samples and from 100 to 2000 pg/l (ppq) in aqueous samples. Absolute recoveries of the method internal standard, (13C12-2,3,7,8-TCDD, ranged from 24 to 88%. Lower levels of detection can be achieved through a slight modification of the method with respect to initial sample size and/or final extract volume. Instrumental parameters that affect data quality, specifically HRGC column performance, mass resolution and mass measurement accuracy are presented.

高分辨率气相色谱/高分辨率质谱法测定土壤和水中2,3,7,8-四氯二苯并-对二恶英的评价
采用高分辨率气相色谱/高分辨率质谱(HRGC/HRMS)对土壤、沉积物和水样中2,3,7,8-四氯二苯并-对二恶英(2,3,7,8- tcdd)和总TCDDs的分析方案进行了评估,并对强化和未加标的土壤和水样进行了重复分析。分析结果表明,该方法适用于土壤样品中浓度为10 ~ 200 pg/g (ppt)和水样中浓度为100 ~ 2000 pg/l (ppq)的2,3,7,8- tcdd和总tcdd的测定。方法内标(13c12 -2,3,7,8- tcdd)的绝对回收率为24% ~ 88%。通过相对于初始样本量和/或最终萃取量对方法进行轻微修改,可以实现较低水平的检测。介绍了影响数据质量的仪器参数,特别是HRGC柱性能、质量分辨率和质量测量精度。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信