The impact of retraction cords on the gingival margin level: A randomized clinical trial.

IF 3.4 2区 医学 Q1 DENTISTRY, ORAL SURGERY & MEDICINE
Majdoleen Fouad, Ahmad Abel Aziz Mahmoud, Mohammad Al-Rabab'ah, Najla Kasabreh
{"title":"The impact of retraction cords on the gingival margin level: A randomized clinical trial.","authors":"Majdoleen Fouad, Ahmad Abel Aziz Mahmoud, Mohammad Al-Rabab'ah, Najla Kasabreh","doi":"10.1111/jopr.14015","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To examine the impact of placing plain and impregnated retraction cords for two different retraction times on the postoperative gingival margin level and periodontal health.</p><p><strong>Materials and methods: </strong>A total of 40 endodontically treated mandibular first molars were selected and randomly allocated into four groups (n = 10/group); A: plain retraction cord for 10 min, B: plain retraction cord, 20 min, C: impregnated (25% aluminum chloride (AlCl<sub>3</sub>) retraction cord, 10 min, D: impregnated retraction cord (25% AlCl<sub>3</sub>), 20 min. Intraoral digital scans were acquired, and periodontal parameters (Plaque index [PI], Bleeding on probing [BOP], and probing depth [PD]) were assessed at baseline, 7 days, and 28 days after retraction. The digital scans were superimposed to measure the change in the mid-buccal gingival margin level. Statistical differences between groups at the threetime points were tested using one-way ANOVA and Chi-square tests (α = 0.05).</p><p><strong>Results: </strong>AlCl<sub>3</sub>-impregnated retraction cord for 20 min resulted in a statistically significant change in gingival margin level than limiting its application to 10 min or using plain cords at the three-time points (p < 0.05) with 88 ± 4 µm gingival recession after 28 days. The assessed periodontal parameters only showed a significant difference between groups in BOP after 7 days of retraction (p = 0.0009); however, all parameters returned to normal after 28 days with no significant difference between groups (p > 0.05).</p><p><strong>Conclusions: </strong>To avoid transient gingival inflammation or permanent gingival recession, no matter how small, the retraction time of AlCl<sub>3</sub>-impregnated cords should be limited to no more than 10 min.</p>","PeriodicalId":49152,"journal":{"name":"Journal of Prosthodontics-Implant Esthetic and Reconstructive Dentistry","volume":"34 2","pages":"139-148"},"PeriodicalIF":3.4000,"publicationDate":"2025-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Prosthodontics-Implant Esthetic and Reconstructive Dentistry","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1111/jopr.14015","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/1/6 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: To examine the impact of placing plain and impregnated retraction cords for two different retraction times on the postoperative gingival margin level and periodontal health.

Materials and methods: A total of 40 endodontically treated mandibular first molars were selected and randomly allocated into four groups (n = 10/group); A: plain retraction cord for 10 min, B: plain retraction cord, 20 min, C: impregnated (25% aluminum chloride (AlCl3) retraction cord, 10 min, D: impregnated retraction cord (25% AlCl3), 20 min. Intraoral digital scans were acquired, and periodontal parameters (Plaque index [PI], Bleeding on probing [BOP], and probing depth [PD]) were assessed at baseline, 7 days, and 28 days after retraction. The digital scans were superimposed to measure the change in the mid-buccal gingival margin level. Statistical differences between groups at the threetime points were tested using one-way ANOVA and Chi-square tests (α = 0.05).

Results: AlCl3-impregnated retraction cord for 20 min resulted in a statistically significant change in gingival margin level than limiting its application to 10 min or using plain cords at the three-time points (p < 0.05) with 88 ± 4 µm gingival recession after 28 days. The assessed periodontal parameters only showed a significant difference between groups in BOP after 7 days of retraction (p = 0.0009); however, all parameters returned to normal after 28 days with no significant difference between groups (p > 0.05).

Conclusions: To avoid transient gingival inflammation or permanent gingival recession, no matter how small, the retraction time of AlCl3-impregnated cords should be limited to no more than 10 min.

求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
7.90
自引率
15.00%
发文量
171
审稿时长
6-12 weeks
期刊介绍: The Journal of Prosthodontics promotes the advanced study and practice of prosthodontics, implant, esthetic, and reconstructive dentistry. It is the official journal of the American College of Prosthodontists, the American Dental Association-recognized voice of the Specialty of Prosthodontics. The journal publishes evidence-based original scientific articles presenting information that is relevant and useful to prosthodontists. Additionally, it publishes reports of innovative techniques, new instructional methodologies, and instructive clinical reports with an interdisciplinary flair. The journal is particularly focused on promoting the study and use of cutting-edge technology and positioning prosthodontists as the early-adopters of new technology in the dental community.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信