Six-minute walk test reveals delayed oxygen uptake kinetics in ischemic cardiomyopathy.

IF 1.9 4区 医学 Q2 BIOLOGY
I S Rocco, B C Matos-Garcia, M Viceconte, C Bublitz, F S Menezes-Rodrigues, F S Tallo, R M Arida, W J Gomes, N A Hossne Junior, R Arena, S Guizilini
{"title":"Six-minute walk test reveals delayed oxygen uptake kinetics in ischemic cardiomyopathy.","authors":"I S Rocco, B C Matos-Garcia, M Viceconte, C Bublitz, F S Menezes-Rodrigues, F S Tallo, R M Arida, W J Gomes, N A Hossne Junior, R Arena, S Guizilini","doi":"10.1590/1414-431X2024e14276","DOIUrl":null,"url":null,"abstract":"<p><p>Although correlated to peak oxygen uptake (VO2), the six-minute walk test (6MWT) alone cannot provide precise physiological insight regarding the specific cause(s) of exercise limitations. We aimed to analyze whether 6MWT is able to properly detect differences in the cardiorespiratory responses between patients with stable coronary artery disease (SCAD) and those with ischemic cardiomyopathy (IC) and determine whether the degree of abnormality in ejection fraction is related with impaired submaximal exercise capacity. Twenty-two subjects with SCAD and 19 subjects with IC underwent a 6MWT while simultaneously using a mobile telemetric cardiopulmonary monitor to assess cardiorespiratory responses. VO2 response at exercise onset was used to obtain VO2 on-kinetics, and the slope of ventilation vs carbon dioxide output (VE/VCO2) was calculated. IC subjects exhibited significantly delayed VO2 on-kinetics compared with the SCAD group (P<0.01) and higher VE/VCO2 slope (IC=40.45 [95%CI: 39.76 to 41.1] vs SCAD=34.36 [95%CI: 34.03 to 34.69], P=0.001). The left ventricular ejection fraction (LVEF) was moderately correlated with VO2 on-kinetics in the SCAD group, but no relationship was found in the IC group. Pulmonary function was correlated with the VE/VCO2 slope only in the IC group. Subjects with IC presented slower VO2 on-kinetics during the 6MWT than those with SCAD. Once reduction in left ventricular function is achieved, LVEF had no association with exercise capacity. Pulmonary function could help identify IC patients at risk of ventilatory inefficiency and may add diagnostic power to the 6MWT.</p>","PeriodicalId":9088,"journal":{"name":"Brazilian Journal of Medical and Biological Research","volume":"58 ","pages":"e14276"},"PeriodicalIF":1.9000,"publicationDate":"2025-02-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11793151/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Brazilian Journal of Medical and Biological Research","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1590/1414-431X2024e14276","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/1/1 0:00:00","PubModel":"eCollection","JCR":"Q2","JCRName":"BIOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Although correlated to peak oxygen uptake (VO2), the six-minute walk test (6MWT) alone cannot provide precise physiological insight regarding the specific cause(s) of exercise limitations. We aimed to analyze whether 6MWT is able to properly detect differences in the cardiorespiratory responses between patients with stable coronary artery disease (SCAD) and those with ischemic cardiomyopathy (IC) and determine whether the degree of abnormality in ejection fraction is related with impaired submaximal exercise capacity. Twenty-two subjects with SCAD and 19 subjects with IC underwent a 6MWT while simultaneously using a mobile telemetric cardiopulmonary monitor to assess cardiorespiratory responses. VO2 response at exercise onset was used to obtain VO2 on-kinetics, and the slope of ventilation vs carbon dioxide output (VE/VCO2) was calculated. IC subjects exhibited significantly delayed VO2 on-kinetics compared with the SCAD group (P<0.01) and higher VE/VCO2 slope (IC=40.45 [95%CI: 39.76 to 41.1] vs SCAD=34.36 [95%CI: 34.03 to 34.69], P=0.001). The left ventricular ejection fraction (LVEF) was moderately correlated with VO2 on-kinetics in the SCAD group, but no relationship was found in the IC group. Pulmonary function was correlated with the VE/VCO2 slope only in the IC group. Subjects with IC presented slower VO2 on-kinetics during the 6MWT than those with SCAD. Once reduction in left ventricular function is achieved, LVEF had no association with exercise capacity. Pulmonary function could help identify IC patients at risk of ventilatory inefficiency and may add diagnostic power to the 6MWT.

求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
4.00
自引率
0.00%
发文量
129
审稿时长
2 months
期刊介绍: The Brazilian Journal of Medical and Biological Research, founded by Michel Jamra, is edited and published monthly by the Associação Brasileira de Divulgação Científica (ABDC), a federation of Brazilian scientific societies: - Sociedade Brasileira de Biofísica (SBBf) - Sociedade Brasileira de Farmacologia e Terapêutica Experimental (SBFTE) - Sociedade Brasileira de Fisiologia (SBFis) - Sociedade Brasileira de Imunologia (SBI) - Sociedade Brasileira de Investigação Clínica (SBIC) - Sociedade Brasileira de Neurociências e Comportamento (SBNeC).
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信