Long-Term Outcomes of a 360-Degree Intracorneal Ring Implantation for Keratoconus: A 10-Year Follow-Up.

IF 1.9 3区 医学 Q2 OPHTHALMOLOGY
Masoud Khorrami-Nejad, Khosrow Jadidi, Zeinab Fadhil Hasan, Hossein Aghamolaei, Qaysser Sattar Abed, Ali Majdi
{"title":"Long-Term Outcomes of a 360-Degree Intracorneal Ring Implantation for Keratoconus: A 10-Year Follow-Up.","authors":"Masoud Khorrami-Nejad, Khosrow Jadidi, Zeinab Fadhil Hasan, Hossein Aghamolaei, Qaysser Sattar Abed, Ali Majdi","doi":"10.1097/ICO.0000000000003832","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To evaluate the long-term visual, refractive, and tomographic outcomes of a 360-degree intracorneal ring implant for treating keratoconus (KC).</p><p><strong>Methods: </strong>This historical cohort study included 29 eyes of 29 patients with KC who underwent MyoRing implantation. Uncorrected and best-corrected distance visual acuity, refraction, keratometry, and corneal thickness were evaluated preoperatively and at 5 and 10 years postoperatively.</p><p><strong>Results: </strong>Significant improvements were observed in all outcome measures at 5 and 10 years postoperatively compared with the preoperative values (P < 0.001). Uncorrected distance visual acuity improved from 1.25 ± 0.34 logarithm of the minimum angle of resolution (logMAR) preoperatively to 0.36 ± 0.24 logMAR at 5 years but showed regression to 0.48 ± 0.35 logMAR at 10 years. Corrected distance visual acuity similarly showed improvement from 0.50 ± 0.24 logMAR preoperatively to 0.18 ± 0.12 logMAR at 5 years, with some regression to 0.25 ± 0.22 logMAR at 10 years. Spherical equivalent improved from -9.38 ± 4.09 diopters (D) preoperatively to -2.70 ± 1.54 D at 5 years but regressed to -3.29 ± 2.22 D at 10 years. Although corneal flattening was observed at 5 years, a slight steepening trend was noted at 10 years. Corneal thickness exhibited an increase after 5 years (P < 0.001), but this trend reversed by the 10-year mark.</p><p><strong>Conclusions: </strong>MyoRing implantation demonstrated significant initial improvements in visual, refractive, and tomographic outcomes in patients with KC; however, some regression toward preoperative values was observed by the 10-year follow-up. This highlights the importance of continued monitoring to assess the long-term impact of the implant and to manage any potential late effects.</p>","PeriodicalId":10710,"journal":{"name":"Cornea","volume":" ","pages":""},"PeriodicalIF":1.9000,"publicationDate":"2025-02-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Cornea","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1097/ICO.0000000000003832","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: To evaluate the long-term visual, refractive, and tomographic outcomes of a 360-degree intracorneal ring implant for treating keratoconus (KC).

Methods: This historical cohort study included 29 eyes of 29 patients with KC who underwent MyoRing implantation. Uncorrected and best-corrected distance visual acuity, refraction, keratometry, and corneal thickness were evaluated preoperatively and at 5 and 10 years postoperatively.

Results: Significant improvements were observed in all outcome measures at 5 and 10 years postoperatively compared with the preoperative values (P < 0.001). Uncorrected distance visual acuity improved from 1.25 ± 0.34 logarithm of the minimum angle of resolution (logMAR) preoperatively to 0.36 ± 0.24 logMAR at 5 years but showed regression to 0.48 ± 0.35 logMAR at 10 years. Corrected distance visual acuity similarly showed improvement from 0.50 ± 0.24 logMAR preoperatively to 0.18 ± 0.12 logMAR at 5 years, with some regression to 0.25 ± 0.22 logMAR at 10 years. Spherical equivalent improved from -9.38 ± 4.09 diopters (D) preoperatively to -2.70 ± 1.54 D at 5 years but regressed to -3.29 ± 2.22 D at 10 years. Although corneal flattening was observed at 5 years, a slight steepening trend was noted at 10 years. Corneal thickness exhibited an increase after 5 years (P < 0.001), but this trend reversed by the 10-year mark.

Conclusions: MyoRing implantation demonstrated significant initial improvements in visual, refractive, and tomographic outcomes in patients with KC; however, some regression toward preoperative values was observed by the 10-year follow-up. This highlights the importance of continued monitoring to assess the long-term impact of the implant and to manage any potential late effects.

角膜内 360 度环植入术治疗角膜炎的长期疗效:10 年随访。
目的:评估 360 度角膜内环植入治疗角膜炎(KC)的长期视觉、屈光和断层成像效果:这项历史性队列研究包括 29 位接受 MyoRing 植入术的 KC 患者的 29 只眼睛。对术前、术后 5 年和 10 年的未矫正和最佳矫正距离视力、屈光度、角膜度数和角膜厚度进行了评估:结果:与术前相比,术后 5 年和 10 年所有结果指标均有显著改善(P < 0.001)。未矫正的远距离视力从术前的 1.25 ± 0.34 最小解像角对数(logMAR)提高到术后 5 年的 0.36 ± 0.24 logMAR,但在术后 10 年又回退到 0.48 ± 0.35 logMAR。矫正后的远距离视力同样从术前的 0.50 ± 0.24 logMAR 提高到 5 年后的 0.18 ± 0.12 logMAR,并在 10 年后回退到 0.25 ± 0.22 logMAR。球面等效度数从术前的 -9.38 ± 4.09 屈光度 (D) 提高到 5 年后的 -2.70 ± 1.54 屈光度,但在 10 年后又回退到 -3.29 ± 2.22 屈光度。虽然在 5 年时观察到角膜变平,但在 10 年时发现角膜有轻微变陡的趋势。角膜厚度在 5 年后有所增加(P < 0.001),但这一趋势在 10 年后逆转:结论:MyoRing 植入术在初期显著改善了 KC 患者的视力、屈光度和断层成像结果,但在 10 年随访中发现,术前数值出现了一些倒退。这凸显了持续监测的重要性,以评估植入物的长期影响并控制任何潜在的后期影响。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Cornea
Cornea 医学-眼科学
CiteScore
5.20
自引率
10.70%
发文量
354
审稿时长
3-6 weeks
期刊介绍: For corneal specialists and for all general ophthalmologists with an interest in this exciting subspecialty, Cornea brings together the latest clinical and basic research on the cornea and the anterior segment of the eye. Each volume is peer-reviewed by Cornea''s board of world-renowned experts and fully indexed in archival format. Your subscription brings you the latest developments in your field and a growing library of valuable professional references. Sponsored by The Cornea Society which was founded as the Castroviejo Cornea Society in 1975.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信