An alumina-modified glassy carbon electrode: a robust platform for accurate nimodipine detection in pharmaceutical applications.

IF 2.7 3区 化学 Q2 CHEMISTRY, ANALYTICAL
Caio Raphael Vanoni, Rayane Bueno Goularte, Adriano Rogério Silva Lima, Nicolly Bittencourt Guedes, Marcos Roberto Scheide, Giovana Carolina Bazzo, Renato L T Parreira, Giovanni Finoto Caramori, Glaucio Régis Nagurniak, Marta Elisa Rosso Dotto, Hellen Karine Stulzer, Cristiane Luisa Jost
{"title":"An alumina-modified glassy carbon electrode: a robust platform for accurate nimodipine detection in pharmaceutical applications.","authors":"Caio Raphael Vanoni, Rayane Bueno Goularte, Adriano Rogério Silva Lima, Nicolly Bittencourt Guedes, Marcos Roberto Scheide, Giovana Carolina Bazzo, Renato L T Parreira, Giovanni Finoto Caramori, Glaucio Régis Nagurniak, Marta Elisa Rosso Dotto, Hellen Karine Stulzer, Cristiane Luisa Jost","doi":"10.1039/d4ay01979b","DOIUrl":null,"url":null,"abstract":"<p><p>Nimodipine (NMP) is a calcium channel blocker known for maintaining blood perfusion, particularly in the brain. Given its importance and widespread applicability, tracking NMP during industrial processes for both pharmaceutical dosage forms and raw material samples is crucial. This article discusses the use of a glassy carbon electrode (GCE) polished with commercial alumina for NMP determination. Atomic force microscopy (AFM) confirmed the presence of residual alumina on the surface of the GCE, and electrochemically active surface area (EASA) analysis demonstrated an enhancement in the active area. The alumina-polished electrode (GCE/AP) exhibited a superior response for NMP, with voltammograms obtained <i>via</i> differential pulse voltammetry (DPV). In this investigation, we employed density functional theory (DFT) calculations to examine the electrochemical characteristics of NMP from a theoretical standpoint. The geometry was optimized by employing the Generalized Gradient Approximation (GGA) functional, BP86, in conjunction with the Def2-TZVPPPD basis set and D3BJ dispersion corrections. To identify potential sites for oxidation and reduction, Fukui indices and dual descriptors were employed. The results indicate that the nitro group is the most probable site for reduction, whereas the dihydropyridine ring displays a proclivity for electrophilic attack. Regarding electroanalysis, two calibration curves were established through consecutive additions of NMP, with linear ranges of 0.20 to 49.0 μmol L<sup>-1</sup> and 2.92 to 13.5 μmol L<sup>-1</sup>, respectively. The theoretical limits of detection (LOD) and quantification (LOQ) were, respectively, 0.06 μmol L<sup>-1</sup> and 0.20 μmol L<sup>-1</sup> for the first curve, and 4.0 μmol L<sup>-1</sup> and 12.0 μmol L<sup>-1</sup> for the second curve. Common constituents in pharmaceutical tablets were tested as potential interferents, and GCE/AP showed acceptable anti-interference ability. NMP was successfully quantified in tablet and raw material samples using the novel electrochemical method and High-Performance Liquid Chromatography (HPLC). Statistical analysis revealed no significant differences between the results. This confirms that the GCE/AP sensor was effectively applied to pharmaceutical samples, consistent with findings reported in the literature.</p>","PeriodicalId":64,"journal":{"name":"Analytical Methods","volume":" ","pages":""},"PeriodicalIF":2.7000,"publicationDate":"2025-02-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Analytical Methods","FirstCategoryId":"92","ListUrlMain":"https://doi.org/10.1039/d4ay01979b","RegionNum":3,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0

Abstract

Nimodipine (NMP) is a calcium channel blocker known for maintaining blood perfusion, particularly in the brain. Given its importance and widespread applicability, tracking NMP during industrial processes for both pharmaceutical dosage forms and raw material samples is crucial. This article discusses the use of a glassy carbon electrode (GCE) polished with commercial alumina for NMP determination. Atomic force microscopy (AFM) confirmed the presence of residual alumina on the surface of the GCE, and electrochemically active surface area (EASA) analysis demonstrated an enhancement in the active area. The alumina-polished electrode (GCE/AP) exhibited a superior response for NMP, with voltammograms obtained via differential pulse voltammetry (DPV). In this investigation, we employed density functional theory (DFT) calculations to examine the electrochemical characteristics of NMP from a theoretical standpoint. The geometry was optimized by employing the Generalized Gradient Approximation (GGA) functional, BP86, in conjunction with the Def2-TZVPPPD basis set and D3BJ dispersion corrections. To identify potential sites for oxidation and reduction, Fukui indices and dual descriptors were employed. The results indicate that the nitro group is the most probable site for reduction, whereas the dihydropyridine ring displays a proclivity for electrophilic attack. Regarding electroanalysis, two calibration curves were established through consecutive additions of NMP, with linear ranges of 0.20 to 49.0 μmol L-1 and 2.92 to 13.5 μmol L-1, respectively. The theoretical limits of detection (LOD) and quantification (LOQ) were, respectively, 0.06 μmol L-1 and 0.20 μmol L-1 for the first curve, and 4.0 μmol L-1 and 12.0 μmol L-1 for the second curve. Common constituents in pharmaceutical tablets were tested as potential interferents, and GCE/AP showed acceptable anti-interference ability. NMP was successfully quantified in tablet and raw material samples using the novel electrochemical method and High-Performance Liquid Chromatography (HPLC). Statistical analysis revealed no significant differences between the results. This confirms that the GCE/AP sensor was effectively applied to pharmaceutical samples, consistent with findings reported in the literature.

求助全文
约1分钟内获得全文 求助全文
来源期刊
Analytical Methods
Analytical Methods CHEMISTRY, ANALYTICAL-FOOD SCIENCE & TECHNOLOGY
CiteScore
5.10
自引率
3.20%
发文量
569
审稿时长
1.8 months
期刊介绍: Early applied demonstrations of new analytical methods with clear societal impact
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信