Parameter and environmental influences on rigid contact lens wettability.

J W Huff, D J Egan, M J Katich
{"title":"Parameter and environmental influences on rigid contact lens wettability.","authors":"J W Huff,&nbsp;D J Egan,&nbsp;M J Katich","doi":"10.1097/00006324-198809000-00005","DOIUrl":null,"url":null,"abstract":"<p><p>The present investigation was designed to determine the effect of lens parameters and lens environment on measurements of contact angle. The sessile drop contact angle of saline on four rigid [polymethyl methacrylate (PMMA) and silicone/acrylate] contact lens materials was examined with a Ramé-Hart goniometer to determine how front surface radius, drop size, time after drop placement, humidity, and desiccation affect measurements of lens wettability in vitro. Contact angles of Silafocon A and PMMA were relatively uninfluenced by front surface radii between 7.7 and 8.85 and 7.3 to 8.8 mm, respectively. Contact angles of Pasifocon C and modified PMMA were slightly but significantly influenced by front surface radii between 6.4 and 7.5 mm. For drop volumes from 2 to 20 microliter, all materials yielded contact angles, which were unaffected by drop size. The contact angle of lenses stored in the hydrated or dehydrated state was not affected by chamber humidity between 31 and 76%. In the ranges tested, drop size, humidity, and hydration had no significant effect on the contact angle within 1 to 6 min after drop placement. In addition, surface scratches had no effect on lens wettability. The results suggest that goniometry on contact lens surfaces, for the most part, is uninfluenced by lens parameters and environmental conditions.</p>","PeriodicalId":7700,"journal":{"name":"American journal of optometry and physiological optics","volume":"65 9","pages":"717-21"},"PeriodicalIF":0.0000,"publicationDate":"1988-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1097/00006324-198809000-00005","citationCount":"5","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"American journal of optometry and physiological optics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1097/00006324-198809000-00005","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 5

Abstract

The present investigation was designed to determine the effect of lens parameters and lens environment on measurements of contact angle. The sessile drop contact angle of saline on four rigid [polymethyl methacrylate (PMMA) and silicone/acrylate] contact lens materials was examined with a Ramé-Hart goniometer to determine how front surface radius, drop size, time after drop placement, humidity, and desiccation affect measurements of lens wettability in vitro. Contact angles of Silafocon A and PMMA were relatively uninfluenced by front surface radii between 7.7 and 8.85 and 7.3 to 8.8 mm, respectively. Contact angles of Pasifocon C and modified PMMA were slightly but significantly influenced by front surface radii between 6.4 and 7.5 mm. For drop volumes from 2 to 20 microliter, all materials yielded contact angles, which were unaffected by drop size. The contact angle of lenses stored in the hydrated or dehydrated state was not affected by chamber humidity between 31 and 76%. In the ranges tested, drop size, humidity, and hydration had no significant effect on the contact angle within 1 to 6 min after drop placement. In addition, surface scratches had no effect on lens wettability. The results suggest that goniometry on contact lens surfaces, for the most part, is uninfluenced by lens parameters and environmental conditions.

参数和环境对硬性隐形眼镜润湿性的影响。
本研究旨在确定透镜参数和透镜环境对接触角测量的影响。用ram -哈特角仪检测了生理盐水在四种刚性[聚甲基丙烯酸甲酯(PMMA)和硅酮/丙烯酸酯]隐形眼镜材料上的无基滴接触角,以确定前表面半径、滴大小、滴入后时间、湿度和干燥对晶状体润湿性的影响。前表面半径在7.7 ~ 8.85 mm和7.3 ~ 8.8 mm之间对硅氟硅酮A和PMMA的接触角影响较小。在6.4 ~ 7.5 mm之间,前表面半径对Pasifocon C和改性PMMA的接触角影响不大,但影响显著。对于2至20微升的液滴体积,所有材料产生的接触角不受液滴大小的影响。在31% ~ 76%的室内湿度范围内,水合或脱水状态下的镜片接触角不受影响。在测试范围内,液滴大小、湿度和水合作用对液滴放置后1 ~ 6 min内的接触角没有显著影响。此外,表面划痕对镜片润湿性没有影响。结果表明,在大多数情况下,隐形眼镜表面的几何形状不受镜片参数和环境条件的影响。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信