Optimal design of a novel three-stage displacement amplifying mechanism with curved-axis flexure hinges

IF 3.5 2区 工程技术 Q2 ENGINEERING, MANUFACTURING
Lei Yuan , Mingxiang Ling , Jianhao Lai , Tingjun Zeng , Hao Xu , Xianmin Zhang
{"title":"Optimal design of a novel three-stage displacement amplifying mechanism with curved-axis flexure hinges","authors":"Lei Yuan ,&nbsp;Mingxiang Ling ,&nbsp;Jianhao Lai ,&nbsp;Tingjun Zeng ,&nbsp;Hao Xu ,&nbsp;Xianmin Zhang","doi":"10.1016/j.precisioneng.2024.11.003","DOIUrl":null,"url":null,"abstract":"<div><div>A novel three-stage displacement amplifying mechanism is proposed by integrating the lever-type, Scott-Russell and double-arm elliptical mechanisms with red blood cell inspired flexure hinges that well balances the displacement amplification ratio and main resonance frequency. Flexure hinges are loaded in tension and bending instead of compression and bending, which can be free from potential buckling problems due to the stress stiffening effects. The combination of the dynamic stiffness matrix method and the discrete-beam transfer matrix method is utilized to rapidly forecast the kinetostatic and dynamic performances of the proposed compliant amplifier, including the curved-axis flexure hinges with complex contour profiles. Then, the Pareto multi-objective optimization strategy, taking those key geometric parameters obtained by the sensitivity analysis into account, is represented based on NSGA-II and a linear frequency solution strategy to accelerate the calculation efficiency and parameter optimization iteration. Based on the application requirement, a point on the Pareto curve is chosen as the optimal configuration for operating conditions. At last, experiments of the piezoelectric compliant amplifier under two types of external mass loads are exhibited. A displacement amplification ratio of 12.2 and main resonance frequency of 1380.5 Hz are achieved for the piezoelectric compliant amplifier under no external mass load.</div></div>","PeriodicalId":54589,"journal":{"name":"Precision Engineering-Journal of the International Societies for Precision Engineering and Nanotechnology","volume":"92 ","pages":"Pages 39-62"},"PeriodicalIF":3.5000,"publicationDate":"2024-11-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Precision Engineering-Journal of the International Societies for Precision Engineering and Nanotechnology","FirstCategoryId":"5","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0141635924002514","RegionNum":2,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ENGINEERING, MANUFACTURING","Score":null,"Total":0}
引用次数: 0

Abstract

A novel three-stage displacement amplifying mechanism is proposed by integrating the lever-type, Scott-Russell and double-arm elliptical mechanisms with red blood cell inspired flexure hinges that well balances the displacement amplification ratio and main resonance frequency. Flexure hinges are loaded in tension and bending instead of compression and bending, which can be free from potential buckling problems due to the stress stiffening effects. The combination of the dynamic stiffness matrix method and the discrete-beam transfer matrix method is utilized to rapidly forecast the kinetostatic and dynamic performances of the proposed compliant amplifier, including the curved-axis flexure hinges with complex contour profiles. Then, the Pareto multi-objective optimization strategy, taking those key geometric parameters obtained by the sensitivity analysis into account, is represented based on NSGA-II and a linear frequency solution strategy to accelerate the calculation efficiency and parameter optimization iteration. Based on the application requirement, a point on the Pareto curve is chosen as the optimal configuration for operating conditions. At last, experiments of the piezoelectric compliant amplifier under two types of external mass loads are exhibited. A displacement amplification ratio of 12.2 and main resonance frequency of 1380.5 Hz are achieved for the piezoelectric compliant amplifier under no external mass load.
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
7.40
自引率
5.60%
发文量
177
审稿时长
46 days
期刊介绍: Precision Engineering - Journal of the International Societies for Precision Engineering and Nanotechnology is devoted to the multidisciplinary study and practice of high accuracy engineering, metrology, and manufacturing. The journal takes an integrated approach to all subjects related to research, design, manufacture, performance validation, and application of high precision machines, instruments, and components, including fundamental and applied research and development in manufacturing processes, fabrication technology, and advanced measurement science. The scope includes precision-engineered systems and supporting metrology over the full range of length scales, from atom-based nanotechnology and advanced lithographic technology to large-scale systems, including optical and radio telescopes and macrometrology.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信