Assessment of electrostatic ignition hazards during water spray cleaning processes above 50 MPa

IF 3.6 3区 工程技术 Q2 ENGINEERING, CHEMICAL
F. Baumann, M. Himstedt, D. Möckel, M. Beyer
{"title":"Assessment of electrostatic ignition hazards during water spray cleaning processes above 50 MPa","authors":"F. Baumann,&nbsp;M. Himstedt,&nbsp;D. Möckel,&nbsp;M. Beyer","doi":"10.1016/j.jlp.2024.105540","DOIUrl":null,"url":null,"abstract":"<div><div>Pump pressures of a few tens to several hundred MPa are used for vessel cleaning processes with water. Where an explosive atmosphere is present, the pump pressure used must be limited to 50 MPa in order to avoid electrostatic ignition hazards due to brush discharges from charged droplet clouds to earthed installed parts. Pressures above 50 MPa are not considered in electrostatic regulations such as technical specification IEC TS 60079-32-1. This pressure limit originates from the performance limits of the cleaning technologies investigated in the past. The pump pressure above which an electrostatic ignition hazard exists is, however, unknown. This limitation works to impair the effectiveness of the cleaning processes. To satisfy the technical state of the art, tests were conducted in vessels of up to 44 m³ and pump pressures of up to 250 MPa. Based on the outcome of these extensive tests and on relevant references, an assessment method is described that takes account of the space charge densities present in the vessel when water is sprayed into it. The derived flow chart enables manufacturers and operators to safely carry out assessments of cleaning processes with water up to 250 MPa in explosive atmospheres, factoring in the vessel dimensions, cleaning technology parameters, and water type. This opens new possibilities for more economical cleaning processes and better-quality cleaning results while maintaining the same level of safety.</div></div>","PeriodicalId":16291,"journal":{"name":"Journal of Loss Prevention in The Process Industries","volume":"94 ","pages":"Article 105540"},"PeriodicalIF":3.6000,"publicationDate":"2024-12-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Loss Prevention in The Process Industries","FirstCategoryId":"5","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0950423024002985","RegionNum":3,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ENGINEERING, CHEMICAL","Score":null,"Total":0}
引用次数: 0

Abstract

Pump pressures of a few tens to several hundred MPa are used for vessel cleaning processes with water. Where an explosive atmosphere is present, the pump pressure used must be limited to 50 MPa in order to avoid electrostatic ignition hazards due to brush discharges from charged droplet clouds to earthed installed parts. Pressures above 50 MPa are not considered in electrostatic regulations such as technical specification IEC TS 60079-32-1. This pressure limit originates from the performance limits of the cleaning technologies investigated in the past. The pump pressure above which an electrostatic ignition hazard exists is, however, unknown. This limitation works to impair the effectiveness of the cleaning processes. To satisfy the technical state of the art, tests were conducted in vessels of up to 44 m³ and pump pressures of up to 250 MPa. Based on the outcome of these extensive tests and on relevant references, an assessment method is described that takes account of the space charge densities present in the vessel when water is sprayed into it. The derived flow chart enables manufacturers and operators to safely carry out assessments of cleaning processes with water up to 250 MPa in explosive atmospheres, factoring in the vessel dimensions, cleaning technology parameters, and water type. This opens new possibilities for more economical cleaning processes and better-quality cleaning results while maintaining the same level of safety.
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
7.20
自引率
14.30%
发文量
226
审稿时长
52 days
期刊介绍: The broad scope of the journal is process safety. Process safety is defined as the prevention and mitigation of process-related injuries and damage arising from process incidents involving fire, explosion and toxic release. Such undesired events occur in the process industries during the use, storage, manufacture, handling, and transportation of highly hazardous chemicals.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信