Europium-based core-shell materials for fluorescence and colorimetric dual-mode sensing of alkaline phosphatase activity

IF 4.1 Q1 CHEMISTRY, ANALYTICAL
Chen-Xi Zhao, Xiao-Xia Li, Yang Shu
{"title":"Europium-based core-shell materials for fluorescence and colorimetric dual-mode sensing of alkaline phosphatase activity","authors":"Chen-Xi Zhao,&nbsp;Xiao-Xia Li,&nbsp;Yang Shu","doi":"10.1016/j.talo.2024.100397","DOIUrl":null,"url":null,"abstract":"<div><div>Abnormal alkaline phosphatase levels have been associated with several diseases, including tumor growth, diabetes, liver dysfunction and so on. Generally, the occurrence and prognosis of these diseases can be reflected by the serum alkaline phosphatase level. In this work, Eu/DBM@SiO<sub>2</sub>@SiO<sub>2</sub> is prepared to protect the internal Eu complex from the external environment by wrapping Eu/DBM inside the silica shell. Then, Eu/DBM@SiO<sub>2</sub>@SiO<sub>2</sub>/MnO<sub>2</sub>, a sensor consists of Eu/DBM@SiO<sub>2</sub>@SiO<sub>2</sub> and MnO<sub>2</sub>, is prepared and applied for alkaline phosphatase detection. MnO<sub>2</sub> is used as the response part of alkaline phosphatase, which can be degraded to Mn<sup>2+</sup> by ascorbic acid. Ascorbic acid is the hydrolysate of alkaline phosphatase. In the process of this reaction, UV–vis absorption of Eu/DBM@SiO<sub>2</sub>@SiO<sub>2</sub>/MnO<sub>2</sub> is reduced and fluorescence is turned on. Alkaline phosphatase concentration is linearly correlated with the logarithmic value of fluorescence enhancement in the range of 10.0–100.0 U/L with linear equation of Lg(F/F<sub>0</sub>)=0.008C-0.030 (R<sup>2</sup>=0.99). For fluorescence method, the LOQ is 10.0 U/L and the LOD is 4.4 U/L. For colorimetric method, the concentration of alkaline phosphatase is linearly correlated with the decrease of absorption intensity in the range of 20.0–90.0 U/L with the linear equation of A/A<sub>0</sub>=-0.012C+1.148 (R<sup>2</sup>=0.99). The LOQ is 20.0 U/L and the LOD is 7.2 U/L. The detection system has good selectivity and can detect alkaline phosphatase in human serum samples, the accuracy of the detection system is verified by the experiment of spike-in experiment. The RSD of alkaline phosphatase concentration in serum samples is in the range of 1.4–8.4 %. This method has potential application in the detection of ALP activity in biological samples.</div></div>","PeriodicalId":436,"journal":{"name":"Talanta Open","volume":"11 ","pages":"Article 100397"},"PeriodicalIF":4.1000,"publicationDate":"2024-12-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Talanta Open","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2666831924001115","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0

Abstract

Abnormal alkaline phosphatase levels have been associated with several diseases, including tumor growth, diabetes, liver dysfunction and so on. Generally, the occurrence and prognosis of these diseases can be reflected by the serum alkaline phosphatase level. In this work, Eu/DBM@SiO2@SiO2 is prepared to protect the internal Eu complex from the external environment by wrapping Eu/DBM inside the silica shell. Then, Eu/DBM@SiO2@SiO2/MnO2, a sensor consists of Eu/DBM@SiO2@SiO2 and MnO2, is prepared and applied for alkaline phosphatase detection. MnO2 is used as the response part of alkaline phosphatase, which can be degraded to Mn2+ by ascorbic acid. Ascorbic acid is the hydrolysate of alkaline phosphatase. In the process of this reaction, UV–vis absorption of Eu/DBM@SiO2@SiO2/MnO2 is reduced and fluorescence is turned on. Alkaline phosphatase concentration is linearly correlated with the logarithmic value of fluorescence enhancement in the range of 10.0–100.0 U/L with linear equation of Lg(F/F0)=0.008C-0.030 (R2=0.99). For fluorescence method, the LOQ is 10.0 U/L and the LOD is 4.4 U/L. For colorimetric method, the concentration of alkaline phosphatase is linearly correlated with the decrease of absorption intensity in the range of 20.0–90.0 U/L with the linear equation of A/A0=-0.012C+1.148 (R2=0.99). The LOQ is 20.0 U/L and the LOD is 7.2 U/L. The detection system has good selectivity and can detect alkaline phosphatase in human serum samples, the accuracy of the detection system is verified by the experiment of spike-in experiment. The RSD of alkaline phosphatase concentration in serum samples is in the range of 1.4–8.4 %. This method has potential application in the detection of ALP activity in biological samples.

Abstract Image

求助全文
约1分钟内获得全文 求助全文
来源期刊
Talanta Open
Talanta Open Chemistry-Analytical Chemistry
CiteScore
5.20
自引率
0.00%
发文量
86
审稿时长
49 days
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信