Physiological impact of the facial mask at rest (2): Modification of Cardiac Variability (HRV) in young athletes

IF 1.1 Q3 SPORT SCIENCES
Ignasi de Yzaguirre Maura , Jaume Escoda i Mora , Mauricio Monaco , Gonzalo Grazioli , Jordi Santiago , Daniel Brotons i Cuixart
{"title":"Physiological impact of the facial mask at rest (2): Modification of Cardiac Variability (HRV) in young athletes","authors":"Ignasi de Yzaguirre Maura ,&nbsp;Jaume Escoda i Mora ,&nbsp;Mauricio Monaco ,&nbsp;Gonzalo Grazioli ,&nbsp;Jordi Santiago ,&nbsp;Daniel Brotons i Cuixart","doi":"10.1016/j.apunsm.2024.100472","DOIUrl":null,"url":null,"abstract":"<div><h3>Introduction</h3><div>During the imperative mandate of mask-wearing during the COVID-19 pandemic, our study aimed to elucidate the physiological repercussions stemming from hypoxia and hypercapnia induced by facemasks during periods of rest. Specifically, we investigated the influence of facemasks on heart rate variability (HRV) within a cohort of young athletes.</div></div><div><h3>Material and methods</h3><div>Experimental study in which 56 competitive adolescent athletes (55 % female) were evaluated. The heart rate data was recorded during 8-min, in meditative rest while seated. We conducted a comprehensive analysis of heart rate variability, examining both a 4-min segment and a 100-beat window. Comparisons were made between data recorded when subjects wore facemasks and when they breathed freely without masks. Data analysis was performed utilizing the Polar ProTrainer 5 software.</div></div><div><h3>Results</h3><div>The results showed relevant statistical differences at the level of cardiac variability (HRV): a) Heart Rate (mask: 70.5 ± 11.3 bpm vs no mask: 71.4 ± 12 bpm; p &lt; 0.043. b) RMSSD (Mask: 56.8 ± 41.1 ms vs no mask: 48.9 ± 30.8 ms p &lt; 0.002). c) RMSSD only 100 beats (mask: 58.1 ± 42.0 ms vs no mask: 46.7 ± 28.4 ms; p &lt; 0.0001).</div></div><div><h3>Conclusions</h3><div>Upon removing the facemask while maintaining meditative rest, 86 % of the subjects exhibited a distinct sympathetic response during the subsequent 5-min period. Notably, in 13 % of participants, this sympathetic response persisted across both phases of the study. Furthermore, the analysis of Ultra-Short-Term Cardiac Variability based on 100 beats accentuated the significance of the observed differences.</div></div>","PeriodicalId":100113,"journal":{"name":"Apunts Sports Medicine","volume":"60 226","pages":"Article 100472"},"PeriodicalIF":1.1000,"publicationDate":"2025-01-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Apunts Sports Medicine","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2666506924000403","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"SPORT SCIENCES","Score":null,"Total":0}
引用次数: 0

Abstract

Introduction

During the imperative mandate of mask-wearing during the COVID-19 pandemic, our study aimed to elucidate the physiological repercussions stemming from hypoxia and hypercapnia induced by facemasks during periods of rest. Specifically, we investigated the influence of facemasks on heart rate variability (HRV) within a cohort of young athletes.

Material and methods

Experimental study in which 56 competitive adolescent athletes (55 % female) were evaluated. The heart rate data was recorded during 8-min, in meditative rest while seated. We conducted a comprehensive analysis of heart rate variability, examining both a 4-min segment and a 100-beat window. Comparisons were made between data recorded when subjects wore facemasks and when they breathed freely without masks. Data analysis was performed utilizing the Polar ProTrainer 5 software.

Results

The results showed relevant statistical differences at the level of cardiac variability (HRV): a) Heart Rate (mask: 70.5 ± 11.3 bpm vs no mask: 71.4 ± 12 bpm; p < 0.043. b) RMSSD (Mask: 56.8 ± 41.1 ms vs no mask: 48.9 ± 30.8 ms p < 0.002). c) RMSSD only 100 beats (mask: 58.1 ± 42.0 ms vs no mask: 46.7 ± 28.4 ms; p < 0.0001).

Conclusions

Upon removing the facemask while maintaining meditative rest, 86 % of the subjects exhibited a distinct sympathetic response during the subsequent 5-min period. Notably, in 13 % of participants, this sympathetic response persisted across both phases of the study. Furthermore, the analysis of Ultra-Short-Term Cardiac Variability based on 100 beats accentuated the significance of the observed differences.
静止时面罩的生理影响(2):改变年轻运动员的心脏变异性(HRV)
在COVID-19大流行期间必须佩戴口罩的情况下,我们的研究旨在阐明休息期间口罩引起的缺氧和高碳酸血症的生理影响。具体来说,我们在一组年轻运动员中调查了口罩对心率变异性(HRV)的影响。材料与方法对56名青少年竞技运动员(55%为女性)进行了实验研究。在静坐冥想休息的8分钟内记录心率数据。我们对心率变异性进行了全面的分析,检查了4分钟段和100次跳动窗口。比较了受试者戴口罩和不戴口罩自由呼吸时记录的数据。使用Polar ProTrainer 5软件进行数据分析。结果两组心脏变异性(HRV)水平差异有统计学意义:a)心率(戴口罩:70.5±11.3 bpm vs不戴口罩:71.4±12 bpm;p & lt;0.043. b) RMSSD(掩膜:56.8±41.1 ms vs无掩膜:48.9±30.8 ms) p <;0.002)。c) RMSSD仅100次跳动(掩膜:58.1±42.0 ms vs无掩膜:46.7±28.4 ms);p & lt;0.0001)。结论取下面罩并保持冥想休息时,86%的受试者在随后的5分钟内表现出明显的交感神经反应。值得注意的是,在13%的参与者中,这种交感反应在研究的两个阶段都持续存在。此外,基于100次心跳的超短期心脏变异性分析强调了观察到的差异的重要性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
2.60
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信