A 60-channel high-density flexible receive array for pediatric abdominal MRI.

IF 3 3区 医学 Q2 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
Wonje Lee, Yunjeong Stickle, Clyve Follante, Thomas Grafendorfer, Taeyoung Yang, Fraser Robb, Fan Zhang, John Pauly, Greig Scott, Shreyas Vasanawala, Ali Syed
{"title":"A 60-channel high-density flexible receive array for pediatric abdominal MRI.","authors":"Wonje Lee, Yunjeong Stickle, Clyve Follante, Thomas Grafendorfer, Taeyoung Yang, Fraser Robb, Fan Zhang, John Pauly, Greig Scott, Shreyas Vasanawala, Ali Syed","doi":"10.1002/mrm.30456","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>Conventional MRI coils offer suboptimal parallel imaging performance for young children. Our goal was to enhance imaging acceleration by dedicated, flexible high-density coil design for pediatric patients at 3T.</p><p><strong>Methods: </strong>We design, construct, and evaluate a highly flexible small loop array. Key design notes include full-wave simulation and analysis of the dual-turn loop, miniature feedboard allocation at the loop center, and cable management. Phantom experiments and adult and pediatric volunteer case studies were conducted to evaluate the small loop array imaging performance compared to commercial reference coils.</p><p><strong>Results: </strong>Dual-turn loop configuration forms higher preamp decoupling impedance than the same size single-turn, supporting a flexible form factor that requires a wide range of critical overlap. Both phantom and in-vivo studies demonstrate superior parallel imaging performance or high spatial resolution imaging using the small loop, compared to commercial reference coils.</p><p><strong>Conclusion: </strong>A dedicated high-density coil array with a minimum inter-component interference layout design allows a flexible form factor and higher imaging accelerations. Phantom and in-vivo volunteer case studies demonstrate promising results in improving efficiency for pediatric patients in routine clinical imaging procedures.</p>","PeriodicalId":18065,"journal":{"name":"Magnetic Resonance in Medicine","volume":" ","pages":""},"PeriodicalIF":3.0000,"publicationDate":"2025-02-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Magnetic Resonance in Medicine","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1002/mrm.30456","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: Conventional MRI coils offer suboptimal parallel imaging performance for young children. Our goal was to enhance imaging acceleration by dedicated, flexible high-density coil design for pediatric patients at 3T.

Methods: We design, construct, and evaluate a highly flexible small loop array. Key design notes include full-wave simulation and analysis of the dual-turn loop, miniature feedboard allocation at the loop center, and cable management. Phantom experiments and adult and pediatric volunteer case studies were conducted to evaluate the small loop array imaging performance compared to commercial reference coils.

Results: Dual-turn loop configuration forms higher preamp decoupling impedance than the same size single-turn, supporting a flexible form factor that requires a wide range of critical overlap. Both phantom and in-vivo studies demonstrate superior parallel imaging performance or high spatial resolution imaging using the small loop, compared to commercial reference coils.

Conclusion: A dedicated high-density coil array with a minimum inter-component interference layout design allows a flexible form factor and higher imaging accelerations. Phantom and in-vivo volunteer case studies demonstrate promising results in improving efficiency for pediatric patients in routine clinical imaging procedures.

求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
6.70
自引率
24.20%
发文量
376
审稿时长
2-4 weeks
期刊介绍: Magnetic Resonance in Medicine (Magn Reson Med) is an international journal devoted to the publication of original investigations concerned with all aspects of the development and use of nuclear magnetic resonance and electron paramagnetic resonance techniques for medical applications. Reports of original investigations in the areas of mathematics, computing, engineering, physics, biophysics, chemistry, biochemistry, and physiology directly relevant to magnetic resonance will be accepted, as well as methodology-oriented clinical studies.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信