Plasma microRNA-145-5p as a diagnostic biomarker for acute deep vein thrombosis

IF 3.4 3区 医学 Q2 HEMATOLOGY
Christopher Antoun , Vårin Eiriksdatter Wikan , Øyvind Øverli , Thor Ueland , Gholamreza Jafari Yeganeh , Sigrid Kufaas Brækkan , Ellen Brodin , John-Bjarne Hansen
{"title":"Plasma microRNA-145-5p as a diagnostic biomarker for acute deep vein thrombosis","authors":"Christopher Antoun ,&nbsp;Vårin Eiriksdatter Wikan ,&nbsp;Øyvind Øverli ,&nbsp;Thor Ueland ,&nbsp;Gholamreza Jafari Yeganeh ,&nbsp;Sigrid Kufaas Brækkan ,&nbsp;Ellen Brodin ,&nbsp;John-Bjarne Hansen","doi":"10.1016/j.rpth.2024.102671","DOIUrl":null,"url":null,"abstract":"<div><h3>Background</h3><div>Identification of new biomarkers for acute deep vein thrombosis (DVT) that could lower the need for diagnostic imaging to confirm or rule out the diagnosis would be advantageous. microRNA-145-5p (miR-145) has the potential to be a diagnostic marker for acute DVT, but its diagnostic performance has not been evaluated in consecutive patients referred to the hospital with suspected DVT.</div></div><div><h3>Objectives</h3><div>The aim of this study was to assess the diagnostic performance of miR-145 for the diagnosis of acute lower extremity DVT.</div></div><div><h3>Methods</h3><div>Patients consecutively referred to the emergency room at Akershus University Hospital (Norway) due to suspicion of acute DVT between June 2021 and July 2023 were included. Within 24 hours of admission, blood was collected for assessment of plasma miR-145 (index test), and whole-leg compression ultrasound (reference standard) was used to confirm or rule out DVT. Cohen’s d effect size and area under the receiver operating curve (AUC) were used to estimate the diagnostic performance of miR-145 and D-dimer.</div></div><div><h3>Results</h3><div>Among 360 included patients, 101 (28%) were diagnosed with DVT. miR-145 showed poor diagnostic performance, as indicated by a Cohen’s d of −0.002 (95% CI, −0.241 to 0.216) and an AUC of 0.59 (95% CI, 0.51-0.67). For D-dimer, Cohen’s d was 1.66 (95% CI, 1.43-1.89), and the AUC was 0.92 (95% CI, 0.86-0.96).</div></div><div><h3>Conclusion</h3><div>Plasma levels of miR-145 showed poor diagnostic performance for lower extremity acute DVT among persons referred to the emergency room with clinical signs and symptoms of DVT.</div></div>","PeriodicalId":20893,"journal":{"name":"Research and Practice in Thrombosis and Haemostasis","volume":"9 1","pages":"Article 102671"},"PeriodicalIF":3.4000,"publicationDate":"2025-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11788850/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Research and Practice in Thrombosis and Haemostasis","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2475037924003662","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"HEMATOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Background

Identification of new biomarkers for acute deep vein thrombosis (DVT) that could lower the need for diagnostic imaging to confirm or rule out the diagnosis would be advantageous. microRNA-145-5p (miR-145) has the potential to be a diagnostic marker for acute DVT, but its diagnostic performance has not been evaluated in consecutive patients referred to the hospital with suspected DVT.

Objectives

The aim of this study was to assess the diagnostic performance of miR-145 for the diagnosis of acute lower extremity DVT.

Methods

Patients consecutively referred to the emergency room at Akershus University Hospital (Norway) due to suspicion of acute DVT between June 2021 and July 2023 were included. Within 24 hours of admission, blood was collected for assessment of plasma miR-145 (index test), and whole-leg compression ultrasound (reference standard) was used to confirm or rule out DVT. Cohen’s d effect size and area under the receiver operating curve (AUC) were used to estimate the diagnostic performance of miR-145 and D-dimer.

Results

Among 360 included patients, 101 (28%) were diagnosed with DVT. miR-145 showed poor diagnostic performance, as indicated by a Cohen’s d of −0.002 (95% CI, −0.241 to 0.216) and an AUC of 0.59 (95% CI, 0.51-0.67). For D-dimer, Cohen’s d was 1.66 (95% CI, 1.43-1.89), and the AUC was 0.92 (95% CI, 0.86-0.96).

Conclusion

Plasma levels of miR-145 showed poor diagnostic performance for lower extremity acute DVT among persons referred to the emergency room with clinical signs and symptoms of DVT.

Abstract Image

求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
5.60
自引率
13.00%
发文量
212
审稿时长
7 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信