AI-assisted diagnosis of multiple sclerosis via optical coherence tomography

IF 3 3区 医学 Q1 OPHTHALMOLOGY
Carlos Santana Plata, Ines Munuera Rufas, Elisa Funes Perez, Jacobo Yañez Merino, María Sopeña Pinilla, Olga Ciubotaru Ciubotaru, Ana Pueyo Bestué, Ignacio Leonardo Pueyo Bestué, Diego Fernandez Velasco, Victor Mallen Gracia
{"title":"AI-assisted diagnosis of multiple sclerosis via optical coherence tomography","authors":"Carlos Santana Plata,&nbsp;Ines Munuera Rufas,&nbsp;Elisa Funes Perez,&nbsp;Jacobo Yañez Merino,&nbsp;María Sopeña Pinilla,&nbsp;Olga Ciubotaru Ciubotaru,&nbsp;Ana Pueyo Bestué,&nbsp;Ignacio Leonardo Pueyo Bestué,&nbsp;Diego Fernandez Velasco,&nbsp;Victor Mallen Gracia","doi":"10.1111/aos.17163","DOIUrl":null,"url":null,"abstract":"<div>\n \n <section>\n \n <p><b>Aims/Purpose:</b> This study aims to evaluate the ability of inter-eye asymmetry and retinal structure thicknesses, obtained via the Posterior Pole protocol in Optical Coherence Tomography (OCT), to distinguish between healthy controls and patients with recently diagnosed multiple sclerosis (MS). Additionally, it aims to develop a convolutional neural network (CNN) for assisted diagnosis using these measurements.</p>\n \n <p><b>Methods:</b> Two cohorts, one with relapsing-remitting MS (RRMS) patients (<i>n</i> = 79) and another with healthy controls (<i>n</i> = 69), were recruited. Structural retinal measurements were obtained using the Spectralis OCT device. The analysis focused on thickness differences in nine retinal layers and their inter-eye asymmetry. Statistical methods included the Shapiro-Wilk test, Student's t-test, χ2 test, and area under the receiver operating characteristic (AUROC) curve. A CNN was trained to classify patients and controls based on the most discriminant retinal measurements.</p>\n \n <p><b>Results:</b> The study found significant thinning in the ganglion cell layer (GCL) and inner plexiform layer (IPL) of RRMS patients compared to controls, with AUROC values of 0.82 and 0.78, respectively. Inter-eye asymmetry was also notable in these layers, particularly the GCL (AUROC = 0.75) and IRL (AUROC = 0.74). The CNN, utilizing GCL thickness and IPL inter-eye difference as inputs, achieved an accuracy of 0.87, sensitivity of 0.82, and specificity of 0.92.</p>\n \n <p><b>Conclusions:</b> The study demonstrates that neuroretinal thinning and inter-eye differences in specific retinal layers, measurable by the Posterior Pole protocol in OCT, can effectively discriminate between MS patients and healthy controls. The CNN developed shows high accuracy in MS diagnosis, supporting the potential of OCT and AI integration in clinical settings. Further research is needed to validate these findings across larger and more diverse populations.</p>\n </section>\n </div>","PeriodicalId":6915,"journal":{"name":"Acta Ophthalmologica","volume":"103 S284","pages":""},"PeriodicalIF":3.0000,"publicationDate":"2025-01-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://onlinelibrary.wiley.com/doi/10.1111/aos.17163","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Acta Ophthalmologica","FirstCategoryId":"3","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1111/aos.17163","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Aims/Purpose: This study aims to evaluate the ability of inter-eye asymmetry and retinal structure thicknesses, obtained via the Posterior Pole protocol in Optical Coherence Tomography (OCT), to distinguish between healthy controls and patients with recently diagnosed multiple sclerosis (MS). Additionally, it aims to develop a convolutional neural network (CNN) for assisted diagnosis using these measurements.

Methods: Two cohorts, one with relapsing-remitting MS (RRMS) patients (n = 79) and another with healthy controls (n = 69), were recruited. Structural retinal measurements were obtained using the Spectralis OCT device. The analysis focused on thickness differences in nine retinal layers and their inter-eye asymmetry. Statistical methods included the Shapiro-Wilk test, Student's t-test, χ2 test, and area under the receiver operating characteristic (AUROC) curve. A CNN was trained to classify patients and controls based on the most discriminant retinal measurements.

Results: The study found significant thinning in the ganglion cell layer (GCL) and inner plexiform layer (IPL) of RRMS patients compared to controls, with AUROC values of 0.82 and 0.78, respectively. Inter-eye asymmetry was also notable in these layers, particularly the GCL (AUROC = 0.75) and IRL (AUROC = 0.74). The CNN, utilizing GCL thickness and IPL inter-eye difference as inputs, achieved an accuracy of 0.87, sensitivity of 0.82, and specificity of 0.92.

Conclusions: The study demonstrates that neuroretinal thinning and inter-eye differences in specific retinal layers, measurable by the Posterior Pole protocol in OCT, can effectively discriminate between MS patients and healthy controls. The CNN developed shows high accuracy in MS diagnosis, supporting the potential of OCT and AI integration in clinical settings. Further research is needed to validate these findings across larger and more diverse populations.

求助全文
约1分钟内获得全文 求助全文
来源期刊
Acta Ophthalmologica
Acta Ophthalmologica 医学-眼科学
CiteScore
7.60
自引率
5.90%
发文量
433
审稿时长
6 months
期刊介绍: Acta Ophthalmologica is published on behalf of the Acta Ophthalmologica Scandinavica Foundation and is the official scientific publication of the following societies: The Danish Ophthalmological Society, The Finnish Ophthalmological Society, The Icelandic Ophthalmological Society, The Norwegian Ophthalmological Society and The Swedish Ophthalmological Society, and also the European Association for Vision and Eye Research (EVER). Acta Ophthalmologica publishes clinical and experimental original articles, reviews, editorials, educational photo essays (Diagnosis and Therapy in Ophthalmology), case reports and case series, letters to the editor and doctoral theses.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信