{"title":"Identifying accurate methods of assessing blood pressure and health information by lay volunteers in the Philippines: Adapting a Canadian cardiometabolic health program to LMICs","authors":"Ricardo Angeles ,&nbsp;Floro Dave Arnuco ,&nbsp;Fortunato Cristobal ,&nbsp;Lisa Dolovich ,&nbsp;Janusz Kaczorowski ,&nbsp;Dale Guenter ,&nbsp;Kasthuri Selvarajah ,&nbsp;Fiona Parascandalo ,&nbsp;Jessica Gaber ,&nbsp;Gina Agarwal","doi":"10.1016/j.cegh.2024.101832","DOIUrl":null,"url":null,"abstract":"<div><h3>Background</h3><div>Hypertension is a leading cause of mortality worldwide, especially in low- and middle-income countries (LMICs). In Canada, the Cardiovascular Health Awareness Program (CHAP) was proven effective in reducing cardiovascular hospitalizations. The next research will evaluate an adapted version of CHAP in the southern Philippines (Community Health Assessment Program in the Philippines (CHAP-P)).</div></div><div><h3>Methods</h3><div>Prior to full program adaptation, this two-phase study was conducted to evaluate the most appropriate methods locally for 1) assessing blood pressure (BP) readings and 2) collecting CHAP-P participant information. Phase 1 compared the correlation (Pearson's <em>r</em>) of BP readings of three automated BP monitoring devices (WatchBP Office Target, Omron HEM-7130, Microlife 3QA1); manual measurement by a health care professional; and the gold standard (trained observers using a mercury sphygmomanometer). Phase 2 compared three data collection methods (tablet, cell phone, and paper) used by Barangay Health Workers (BHWs), the local volunteers who will implement the intervention. Errors, missed data, and BHW experiences were explored during each phase.</div></div><div><h3>Results</h3><div>Phase 1: the device most highly correlated with the gold standard for systolic BP was the WatchBP Office Target (<em>r</em> = 0.84). For diastolic BP, the WatchBP Office Target produced the same result as the Omron HEM-7130 (<em>r</em> = 0.67). Manual BP measurement showed a very poor correlation (<em>r</em> &lt; 0.60) with the gold standard. Phase 2: BHWs found cell phones and tablets more accurate and easier than paper. They preferred tablets due to the larger screen.</div></div><div><h3>Conclusion</h3><div>The WatchBP Office target and tablet will be used in the next phase of the project.</div></div>","PeriodicalId":46404,"journal":{"name":"Clinical Epidemiology and Global Health","volume":"31 ","pages":"Article 101832"},"PeriodicalIF":2.3000,"publicationDate":"2025-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Clinical Epidemiology and Global Health","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2213398424003294","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"PUBLIC, ENVIRONMENTAL & OCCUPATIONAL HEALTH","Score":null,"Total":0}
引用次数: 0

Abstract

Background

Hypertension is a leading cause of mortality worldwide, especially in low- and middle-income countries (LMICs). In Canada, the Cardiovascular Health Awareness Program (CHAP) was proven effective in reducing cardiovascular hospitalizations. The next research will evaluate an adapted version of CHAP in the southern Philippines (Community Health Assessment Program in the Philippines (CHAP-P)).

Methods

Prior to full program adaptation, this two-phase study was conducted to evaluate the most appropriate methods locally for 1) assessing blood pressure (BP) readings and 2) collecting CHAP-P participant information. Phase 1 compared the correlation (Pearson's r) of BP readings of three automated BP monitoring devices (WatchBP Office Target, Omron HEM-7130, Microlife 3QA1); manual measurement by a health care professional; and the gold standard (trained observers using a mercury sphygmomanometer). Phase 2 compared three data collection methods (tablet, cell phone, and paper) used by Barangay Health Workers (BHWs), the local volunteers who will implement the intervention. Errors, missed data, and BHW experiences were explored during each phase.

Results

Phase 1: the device most highly correlated with the gold standard for systolic BP was the WatchBP Office Target (r = 0.84). For diastolic BP, the WatchBP Office Target produced the same result as the Omron HEM-7130 (r = 0.67). Manual BP measurement showed a very poor correlation (r < 0.60) with the gold standard. Phase 2: BHWs found cell phones and tablets more accurate and easier than paper. They preferred tablets due to the larger screen.

Conclusion

The WatchBP Office target and tablet will be used in the next phase of the project.
求助全文
约1分钟内获得全文 求助全文
来源期刊
Clinical Epidemiology and Global Health
Clinical Epidemiology and Global Health PUBLIC, ENVIRONMENTAL & OCCUPATIONAL HEALTH-
CiteScore
4.60
自引率
7.70%
发文量
218
审稿时长
66 days
期刊介绍: Clinical Epidemiology and Global Health (CEGH) is a multidisciplinary journal and it is published four times (March, June, September, December) a year. The mandate of CEGH is to promote articles on clinical epidemiology with focus on developing countries in the context of global health. We also accept articles from other countries. It publishes original research work across all disciplines of medicine and allied sciences, related to clinical epidemiology and global health. The journal publishes Original articles, Review articles, Evidence Summaries, Letters to the Editor. All articles published in CEGH are peer-reviewed and published online for immediate access and citation.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信