Effect of attachment type and implant position on the retention of mandibular implant-supported overdentures.

Q4 Dentistry
Alireza Saadati, Farnaz Taghavi-Damghani, Sara Tavakolizadeh, Alireza Hadi
{"title":"Effect of attachment type and implant position on the retention of mandibular implant-supported overdentures.","authors":"Alireza Saadati, Farnaz Taghavi-Damghani, Sara Tavakolizadeh, Alireza Hadi","doi":"10.34172/joddd.41514","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>In implant-supported overdentures increase in the number of implants improves the retention and stability of the overdentures. A direct correlation exists between prosthesis retention and patient satisfaction. Therefore, this experimental study assessed the effect of attachment type and implant position on the retention of mandibular implant-supported overdentures.</p><p><strong>Methods: </strong>A transparent acrylic resin model of the mandible was fabricated, and dental implants were positioned at the first molar area (position 6), between the lateral incisor and canine teeth (positions B and D), and first premolars (positions A and E) bilaterally. Novaloc attachments (strong, medium, and light retentive caps) were used with ABDE, 6AE6, and 6BD6 implant positions. A Dolder bar attachment was also used with the ABDE implant position. Overdenture retention was measured under vertical loading, and the maximum dislodging force (MDF) was recorded. Data were analyzed by two-way and one-way ANOVA and post hoc Tukey tests (α=0.05).</p><p><strong>Results: </strong>The effects of attachment type and implant position [except for ABDE and 6AE6 with light retention insert (<i>P</i>=0.49), and 6AE6 and 6BD6 with strong retention insert (<i>P</i>=0.48)], and their interaction effect were significant on MDF (<i>P</i><0.01). The highest retention was recorded for bar attachment (65.15 N), with the lowest for Novaloc attachment with light retention insert at ABDE implant position (11.97 N).</p><p><strong>Conclusion: </strong>With Novaloc attachments, minimum retention was recorded in ABDE, and maximum retention was recorded in the 6BD6 implant position due to the increased distance between attachments. The strong insert showed the highest retention value, which confirmed the manufacturer's claim. Maximum retention was recorded with the bar and clip attachment.</p>","PeriodicalId":15599,"journal":{"name":"Journal of Dental Research, Dental Clinics, Dental Prospects","volume":"18 4","pages":"249-257"},"PeriodicalIF":0.0000,"publicationDate":"2024-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11786009/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Dental Research, Dental Clinics, Dental Prospects","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.34172/joddd.41514","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/12/14 0:00:00","PubModel":"Epub","JCR":"Q4","JCRName":"Dentistry","Score":null,"Total":0}
引用次数: 0

Abstract

Background: In implant-supported overdentures increase in the number of implants improves the retention and stability of the overdentures. A direct correlation exists between prosthesis retention and patient satisfaction. Therefore, this experimental study assessed the effect of attachment type and implant position on the retention of mandibular implant-supported overdentures.

Methods: A transparent acrylic resin model of the mandible was fabricated, and dental implants were positioned at the first molar area (position 6), between the lateral incisor and canine teeth (positions B and D), and first premolars (positions A and E) bilaterally. Novaloc attachments (strong, medium, and light retentive caps) were used with ABDE, 6AE6, and 6BD6 implant positions. A Dolder bar attachment was also used with the ABDE implant position. Overdenture retention was measured under vertical loading, and the maximum dislodging force (MDF) was recorded. Data were analyzed by two-way and one-way ANOVA and post hoc Tukey tests (α=0.05).

Results: The effects of attachment type and implant position [except for ABDE and 6AE6 with light retention insert (P=0.49), and 6AE6 and 6BD6 with strong retention insert (P=0.48)], and their interaction effect were significant on MDF (P<0.01). The highest retention was recorded for bar attachment (65.15 N), with the lowest for Novaloc attachment with light retention insert at ABDE implant position (11.97 N).

Conclusion: With Novaloc attachments, minimum retention was recorded in ABDE, and maximum retention was recorded in the 6BD6 implant position due to the increased distance between attachments. The strong insert showed the highest retention value, which confirmed the manufacturer's claim. Maximum retention was recorded with the bar and clip attachment.

求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
1.40
自引率
0.00%
发文量
23
审稿时长
25 weeks
期刊介绍: Journal of Dental Research Dental Clinics Dental Prospects (JODDD) is a Platinum* Open Access, peer-reviewed quarterly indexed journal that publishes articles of basic, clinical, and prospective nature in all areas of dentistry and oral health.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信