Monitoring of occupational exposure to hazardous medicinal products in robotic compounding.

IF 1.6 4区 医学 Q3 PHARMACOLOGY & PHARMACY
Ana C Riestra, Mikel Urretavizcaya, Alexander Ferro Uriguen, Olatz Olariaga Sarasola, Ainara Iglesias, Yoana Camba, Ainhoa Asensio Bermejo, Maria Jose Tames
{"title":"Monitoring of occupational exposure to hazardous medicinal products in robotic compounding.","authors":"Ana C Riestra, Mikel Urretavizcaya, Alexander Ferro Uriguen, Olatz Olariaga Sarasola, Ainara Iglesias, Yoana Camba, Ainhoa Asensio Bermejo, Maria Jose Tames","doi":"10.1136/ejhpharm-2024-004294","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>This study aims to evaluate the risk of occupational exposure to hazardous medicinal products (HMPs) when utilising robotic compounding systems for the preparation of antineoplastic sterile medications. Specifically, it assesses the levels of HMPs present on the surfaces of ready-to-use preparations and on the gloves worn by personnel involved in the compounding process.</p><p><strong>Methods: </strong>The study was conducted over three consecutive days during routine production with a robotic compounding system. Each day, wipe samples were collected from the surfaces of 20 HMPs preparations and from the gloves of the operator involved in the compounding process. Analyses were performed using an Ultra-High Performance Liquid Chromatography (UHPLC) system to detect and quantify 25 commonly used anticancer molecules in hospital pharmacies.</p><p><strong>Results: </strong>Throughout the study, the robot compounded 60 bags of 19 different drugs, including 5-fluorouracil, bevacizumab, carboplatin, cisplatin, cyclophosphamide, docetaxel, doxorubicin, eribulin, etoposide, gemcitabine, irinotecan, nivolumab, oxaliplatin, paclitaxel, panitumumab, pembrolizumab, pemetrexed, trastuzumab, and vinorelbine. Only negligible amounts of gemcitabine, below the quantification limit (<0.0025 ng/cm²), were detected on the surfaces of 10 out of the 60 bags and on two of the operator's gloves.</p><p><strong>Conclusion: </strong>The results demonstrate that surface contamination levels of HMPs in robotic compounding are exceedingly low and, in most cases, undetectable. Occupational exposure to HMPs remains consistently below 0.1 ng/cm<sup>2</sup>, a threshold deemed safe according to various studies. These findings assure the safety of compounding personnel and other hospital staff involved in cancer treatment.</p>","PeriodicalId":12050,"journal":{"name":"European journal of hospital pharmacy : science and practice","volume":" ","pages":""},"PeriodicalIF":1.6000,"publicationDate":"2025-01-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"European journal of hospital pharmacy : science and practice","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1136/ejhpharm-2024-004294","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"PHARMACOLOGY & PHARMACY","Score":null,"Total":0}
引用次数: 0

Abstract

Objective: This study aims to evaluate the risk of occupational exposure to hazardous medicinal products (HMPs) when utilising robotic compounding systems for the preparation of antineoplastic sterile medications. Specifically, it assesses the levels of HMPs present on the surfaces of ready-to-use preparations and on the gloves worn by personnel involved in the compounding process.

Methods: The study was conducted over three consecutive days during routine production with a robotic compounding system. Each day, wipe samples were collected from the surfaces of 20 HMPs preparations and from the gloves of the operator involved in the compounding process. Analyses were performed using an Ultra-High Performance Liquid Chromatography (UHPLC) system to detect and quantify 25 commonly used anticancer molecules in hospital pharmacies.

Results: Throughout the study, the robot compounded 60 bags of 19 different drugs, including 5-fluorouracil, bevacizumab, carboplatin, cisplatin, cyclophosphamide, docetaxel, doxorubicin, eribulin, etoposide, gemcitabine, irinotecan, nivolumab, oxaliplatin, paclitaxel, panitumumab, pembrolizumab, pemetrexed, trastuzumab, and vinorelbine. Only negligible amounts of gemcitabine, below the quantification limit (<0.0025 ng/cm²), were detected on the surfaces of 10 out of the 60 bags and on two of the operator's gloves.

Conclusion: The results demonstrate that surface contamination levels of HMPs in robotic compounding are exceedingly low and, in most cases, undetectable. Occupational exposure to HMPs remains consistently below 0.1 ng/cm2, a threshold deemed safe according to various studies. These findings assure the safety of compounding personnel and other hospital staff involved in cancer treatment.

求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
3.40
自引率
5.90%
发文量
104
审稿时长
6-12 weeks
期刊介绍: European Journal of Hospital Pharmacy (EJHP) offers a high quality, peer-reviewed platform for the publication of practical and innovative research which aims to strengthen the profile and professional status of hospital pharmacists. EJHP is committed to being the leading journal on all aspects of hospital pharmacy, thereby advancing the science, practice and profession of hospital pharmacy. The journal aims to become a major source for education and inspiration to improve practice and the standard of patient care in hospitals and related institutions worldwide. EJHP is the only official journal of the European Association of Hospital Pharmacists.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信