Computed tomography enterography-based radiomics nomograms to predict inflammatory activity for ileocolonic Crohn's disease: a preliminary single-center retrospective study.

IF 2.9 3区 医学 Q2 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
Yuping Ma, Luanxin Zhu, Bota Cui, Faming Zhang, Haige Li, Jianguo Zhu
{"title":"Computed tomography enterography-based radiomics nomograms to predict inflammatory activity for ileocolonic Crohn's disease: a preliminary single-center retrospective study.","authors":"Yuping Ma, Luanxin Zhu, Bota Cui, Faming Zhang, Haige Li, Jianguo Zhu","doi":"10.1186/s12880-025-01560-0","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>This study aims to develop and validate nomograms that utilize morphological and radiomics features derived from computed tomography enterography (CTE) to evaluate inflammatory activity in patients with ileocolonic Crohn's disease (CD).</p><p><strong>Methods: </strong>A total of 54 CD patients (237 bowel segments) with clinically confirmed CD were retrospectively analyzed. The Simple Endoscopic Score for Crohn's Disease (SES-CD) was used as a reference standard to quantify the degree of mucosal inflammation and assess disease severity. We extracted morphological and radiomics features in the training cohort to create a morphological model (M-score) and a radiomics model (Rad-score). A combined nomogram was generated by integrating the M-score and Rad-score. The predictive performance of each model was evaluated using receiver operating characteristic (ROC) curve analysis. Additionally, calibration curve and decision curve analysis (DCA) were employed to assess the accuracy and clinical applicability of the nomogram in the testing cohort.</p><p><strong>Results: </strong>The area under the ROC curve (AUC) for the nomogram, which included stenosis, comb sign, and Rad-score, was 0.834 [95% confidence interval (CI): 0.728-0.940] for distinguishing between active and remissive disease. Furthermore, the nomogram created using comb sign and Rad-score achieved a satisfactory AUC of 0.781 (95% CI: 0.611-0.951) in differentiating mild activity from moderate-to-severe activity. The calibration curve and DCA confirmed both nomograms' accuracy and clinical utility.</p><p><strong>Conclusions: </strong>Nomograms that combined CTE-based radiomics and morphological features could serve as valuable tools for assessing inflammatory activity, thereby supporting clinical decision-making in managing CD.</p><p><strong>Keypoints: </strong>1. Radiomics features from CTE could predict the inflammatory activity of CD.</p>","PeriodicalId":9020,"journal":{"name":"BMC Medical Imaging","volume":"25 1","pages":"27"},"PeriodicalIF":2.9000,"publicationDate":"2025-01-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11771071/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"BMC Medical Imaging","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1186/s12880-025-01560-0","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

Abstract

Objectives: This study aims to develop and validate nomograms that utilize morphological and radiomics features derived from computed tomography enterography (CTE) to evaluate inflammatory activity in patients with ileocolonic Crohn's disease (CD).

Methods: A total of 54 CD patients (237 bowel segments) with clinically confirmed CD were retrospectively analyzed. The Simple Endoscopic Score for Crohn's Disease (SES-CD) was used as a reference standard to quantify the degree of mucosal inflammation and assess disease severity. We extracted morphological and radiomics features in the training cohort to create a morphological model (M-score) and a radiomics model (Rad-score). A combined nomogram was generated by integrating the M-score and Rad-score. The predictive performance of each model was evaluated using receiver operating characteristic (ROC) curve analysis. Additionally, calibration curve and decision curve analysis (DCA) were employed to assess the accuracy and clinical applicability of the nomogram in the testing cohort.

Results: The area under the ROC curve (AUC) for the nomogram, which included stenosis, comb sign, and Rad-score, was 0.834 [95% confidence interval (CI): 0.728-0.940] for distinguishing between active and remissive disease. Furthermore, the nomogram created using comb sign and Rad-score achieved a satisfactory AUC of 0.781 (95% CI: 0.611-0.951) in differentiating mild activity from moderate-to-severe activity. The calibration curve and DCA confirmed both nomograms' accuracy and clinical utility.

Conclusions: Nomograms that combined CTE-based radiomics and morphological features could serve as valuable tools for assessing inflammatory activity, thereby supporting clinical decision-making in managing CD.

Keypoints: 1. Radiomics features from CTE could predict the inflammatory activity of CD.

求助全文
约1分钟内获得全文 求助全文
来源期刊
BMC Medical Imaging
BMC Medical Imaging RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING-
CiteScore
4.60
自引率
3.70%
发文量
198
审稿时长
27 weeks
期刊介绍: BMC Medical Imaging is an open access journal publishing original peer-reviewed research articles in the development, evaluation, and use of imaging techniques and image processing tools to diagnose and manage disease.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信