Confined active area and aggregation kinetic-based AuNPs@PVP nanosensors for simultaneous colorimetric detection of cysteine and homocysteine as homologues in human urine and serum.

IF 5.3 2区 化学 Q1 CHEMISTRY, ANALYTICAL
Hua-Li Li, Jie-Ling Liang, Shun-Xing Li, Feng-Jiao Liu, Jia-Yi Luo, Zhao-Jing Huang, Feng-Ying Zheng, Ling-Ling Su, You-Bin Zhuo
{"title":"Confined active area and aggregation kinetic-based AuNPs@PVP nanosensors for simultaneous colorimetric detection of cysteine and homocysteine as homologues in human urine and serum.","authors":"Hua-Li Li, Jie-Ling Liang, Shun-Xing Li, Feng-Jiao Liu, Jia-Yi Luo, Zhao-Jing Huang, Feng-Ying Zheng, Ling-Ling Su, You-Bin Zhuo","doi":"10.1007/s00604-025-06962-z","DOIUrl":null,"url":null,"abstract":"<p><p>The detection of cysteine (Cys) and homocysteine (Hcy) in biological fluids has great significance for early diagnosis, including Alzheimer's and Parkinson's disease. The simultaneous determination of Cys and Hcy with a single probe is still a huge challenge. To enlarge the differences in space structure (line and ring) and energy (-721.78 and -761.08 Hartree) between Cys and Hcy, and to cause a difference of aggregation kinetics, gold nanoparticles (AuNPs) are capped with hydrophilic and low-toxic polyvinylpyrrolidone (PVP) (named AuNPs@PVP) and some surface-active sites of AuNPs are masked, the active area for the binding between AuNPs and the detection object is confined, meanwhile, the stability of AuNPs is improved. A novel nanosensor based on confined active area and aggregation kinetics of AuNPs@PVP, is designed for the identification and determination of Cys and Hcy in 1 and 3 min, respectively, with sufficiently low detection limit (4.12 and 4.35 μM) and linear range (4.12-100 μM) for health evaluation. This single colorimetric sensor was applied successfully to the determination of urine and serum, evidencing high anti-interference ability.</p>","PeriodicalId":705,"journal":{"name":"Microchimica Acta","volume":"192 2","pages":"108"},"PeriodicalIF":5.3000,"publicationDate":"2025-01-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Microchimica Acta","FirstCategoryId":"92","ListUrlMain":"https://doi.org/10.1007/s00604-025-06962-z","RegionNum":2,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0

Abstract

The detection of cysteine (Cys) and homocysteine (Hcy) in biological fluids has great significance for early diagnosis, including Alzheimer's and Parkinson's disease. The simultaneous determination of Cys and Hcy with a single probe is still a huge challenge. To enlarge the differences in space structure (line and ring) and energy (-721.78 and -761.08 Hartree) between Cys and Hcy, and to cause a difference of aggregation kinetics, gold nanoparticles (AuNPs) are capped with hydrophilic and low-toxic polyvinylpyrrolidone (PVP) (named AuNPs@PVP) and some surface-active sites of AuNPs are masked, the active area for the binding between AuNPs and the detection object is confined, meanwhile, the stability of AuNPs is improved. A novel nanosensor based on confined active area and aggregation kinetics of AuNPs@PVP, is designed for the identification and determination of Cys and Hcy in 1 and 3 min, respectively, with sufficiently low detection limit (4.12 and 4.35 μM) and linear range (4.12-100 μM) for health evaluation. This single colorimetric sensor was applied successfully to the determination of urine and serum, evidencing high anti-interference ability.

求助全文
约1分钟内获得全文 求助全文
来源期刊
Microchimica Acta
Microchimica Acta 化学-分析化学
CiteScore
9.80
自引率
5.30%
发文量
410
审稿时长
2.7 months
期刊介绍: As a peer-reviewed journal for analytical sciences and technologies on the micro- and nanoscale, Microchimica Acta has established itself as a premier forum for truly novel approaches in chemical and biochemical analysis. Coverage includes methods and devices that provide expedient solutions to the most contemporary demands in this area. Examples are point-of-care technologies, wearable (bio)sensors, in-vivo-monitoring, micro/nanomotors and materials based on synthetic biology as well as biomedical imaging and targeting.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信