Test-Retest Reliability and Validity of TecnoBody D-Wall to Assess the Range of Motion During Overhead Squat in Healthy Individuals.

IF 3.2 3区 生物学 Q1 BIOLOGY
Life-Basel Pub Date : 2025-01-10 DOI:10.3390/life15010080
Caglar Soylu, Gorkem Acar, Berkay Uzumcu, Pervin Demir, Sinan Seyhan, Turker Biyikli
{"title":"Test-Retest Reliability and Validity of TecnoBody D-Wall to Assess the Range of Motion During Overhead Squat in Healthy Individuals.","authors":"Caglar Soylu, Gorkem Acar, Berkay Uzumcu, Pervin Demir, Sinan Seyhan, Turker Biyikli","doi":"10.3390/life15010080","DOIUrl":null,"url":null,"abstract":"<p><p>This study evaluated the validity and reliability of the TecnoBody D-Wall system in assessing joint range of motion (ROM) during overhead squat movements in healthy individuals, using Kinovea as a reference tool for data comparison. A total of 29 participants (16 males, 13 females) with a mean age of 28.41 ± 6.66 years were included. Measurements were conducted for hip and knee joint angles in the sagittal plane, with three repetitions per participant analyzed using both systems. The D-Wall system employed a 3D Kinect V2 camera and force platform, while Kinovea used 2D video-based motion analysis. The results demonstrated excellent agreement between the two systems, with intra-class correlation coefficients (ICC) ranging from 0.79 to 0.99. For the knee joint, the test-retest ICC values were 0.99 (95% CI: 0.97-0.99) for Kinovea and 0.98 (95% CI: 0.95-0.99) for the D-Wall on the right side, and 0.98 (95% CI: 0.97-0.99) for Kinovea and 0.88 (95% CI: 0.79-0.94) for the D-Wall on the left side. For the hip joint, test-retest ICC values were 0.99 (95% CI: 0.97-0.99) for Kinovea and 0.94 (95% CI: 0.88-0.97) for the D-Wall on the right side, and 0.98 (95% CI: 0.97-0.99) for Kinovea and 0.93 (95% CI: 0.87-0.97) for the D-Wall on the left side. Bland-Altman plots confirmed good agreement, with no significant systematic bias observed. Both systems showed statistically insignificant differences (<i>p</i> > 0.05) between measurements, and correlation values ranged from 0.83 to 0.99, indicating strong associations. These findings highlight the high validity and reliability of both TecnoBody D-Wall and Kinovea systems in measuring joint angles during dynamic movements. The comparable accuracy between systems suggests that either system can be effectively utilized in clinical or research settings, depending on specific needs and resource availability.</p>","PeriodicalId":56144,"journal":{"name":"Life-Basel","volume":"15 1","pages":""},"PeriodicalIF":3.2000,"publicationDate":"2025-01-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11766738/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Life-Basel","FirstCategoryId":"99","ListUrlMain":"https://doi.org/10.3390/life15010080","RegionNum":3,"RegionCategory":"生物学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"BIOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

This study evaluated the validity and reliability of the TecnoBody D-Wall system in assessing joint range of motion (ROM) during overhead squat movements in healthy individuals, using Kinovea as a reference tool for data comparison. A total of 29 participants (16 males, 13 females) with a mean age of 28.41 ± 6.66 years were included. Measurements were conducted for hip and knee joint angles in the sagittal plane, with three repetitions per participant analyzed using both systems. The D-Wall system employed a 3D Kinect V2 camera and force platform, while Kinovea used 2D video-based motion analysis. The results demonstrated excellent agreement between the two systems, with intra-class correlation coefficients (ICC) ranging from 0.79 to 0.99. For the knee joint, the test-retest ICC values were 0.99 (95% CI: 0.97-0.99) for Kinovea and 0.98 (95% CI: 0.95-0.99) for the D-Wall on the right side, and 0.98 (95% CI: 0.97-0.99) for Kinovea and 0.88 (95% CI: 0.79-0.94) for the D-Wall on the left side. For the hip joint, test-retest ICC values were 0.99 (95% CI: 0.97-0.99) for Kinovea and 0.94 (95% CI: 0.88-0.97) for the D-Wall on the right side, and 0.98 (95% CI: 0.97-0.99) for Kinovea and 0.93 (95% CI: 0.87-0.97) for the D-Wall on the left side. Bland-Altman plots confirmed good agreement, with no significant systematic bias observed. Both systems showed statistically insignificant differences (p > 0.05) between measurements, and correlation values ranged from 0.83 to 0.99, indicating strong associations. These findings highlight the high validity and reliability of both TecnoBody D-Wall and Kinovea systems in measuring joint angles during dynamic movements. The comparable accuracy between systems suggests that either system can be effectively utilized in clinical or research settings, depending on specific needs and resource availability.

求助全文
约1分钟内获得全文 求助全文
来源期刊
Life-Basel
Life-Basel Biochemistry, Genetics and Molecular Biology-General Biochemistry,Genetics and Molecular Biology
CiteScore
4.30
自引率
6.20%
发文量
1798
审稿时长
11 weeks
期刊介绍: Life (ISSN 2075-1729) is an international, peer-reviewed open access journal of scientific studies related to fundamental themes in Life Sciences, especially those concerned with the origins of life and evolution of biosystems. Our aim is to encourage scientists to publish their experimental and theoretical results in as much detail as possible. There is no restriction on the length of the papers.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信