Glenoid Preparation in Reverse Shoulder Arthroplasty: Robotic-Arm Assisted Preparation Compared to Manual Preparation and Patient-specific Guides.

IF 2.9 2区 医学 Q1 ORTHOPEDICS
George S Athwal, Andrew Nelson, Samuel Antuna, Brent Ponce, Mark Mighell, Patrick St Pierre, Joaquin Sanchez-Sotelo
{"title":"Glenoid Preparation in Reverse Shoulder Arthroplasty: Robotic-Arm Assisted Preparation Compared to Manual Preparation and Patient-specific Guides.","authors":"George S Athwal, Andrew Nelson, Samuel Antuna, Brent Ponce, Mark Mighell, Patrick St Pierre, Joaquin Sanchez-Sotelo","doi":"10.1016/j.jse.2024.12.007","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Precise and accurate glenoid preparation is important for the success of shoulder arthroplasty. Despite advancements in preoperative planning software and enabling technologies, most surgeons execute the procedure manually. Patient-specific instrumentation (PSI) facilitates accurate glenoid guide pin placement for cannulated reaming; however, few commercially available systems offer depth of reaming control. Robotic-arm assisted bone preparation has gained popularity in knee and hip arthroplasty, but at the present time there is limited information available on the use of robotics for shoulder arthroplasty. The purpose of this study was to compare glenoid preparation and final implant position using three techniques: manual, manual assisted with PSI, and robotic arm assisted bone preparation.</p><p><strong>Methods: </strong>Six shoulder surgeons participated in this study utilizing three preparation techniques: (1) manual reaming, (2) manual reaming over a pin inserted using PSI, and (3) preparation using a robotic arm assist with an end-effector burr and haptic boundaries. Each surgeon randomly conducted each technique on 2 separate Bone Matrix glenoid models, for a total of 36 glenoid models tested. To compare the techniques, the final prepared Bone Matrix models underwent a CT scan with 3D virtual model generation. The prepared 3D virtual glenoid models were then compared to the preoperatively planned models. Parameters compared included deviations in version, inclination, anterior-posterior (AP) translation, superior-inferior (SI) translation, and depth of reaming.</p><p><strong>Results: </strong>Regarding glenoid version with values reported as mean deviations from the preoperative plan, the robotic-assisted technique (1°) was significantly better than manual (9°, p<0.001) and PSI (4°, p<0.001) techniques at executing the preoperative plan. Regarding inclination, the robotic-assisted technique (2°) was significantly better than manual (9°, p=0.003) but not significantly different than PSI (3°, p=0.211). The robotic-arm technique, with AP translation, resulted in significantly lower mean displacements (0.3mm) than the manual technique (2mm, p=0.001) and the PSI technique (2mm, p=0.002). With SI translation, the robotic-arm assisted technique (0.7mm) resulted in significantly lower mean displacements as compared to the manual (2mm, p=0.007) and PSI (1mm, p=0.011). The robotic-arm assisted technique (0.4 mm) did not result in significantly lower mean depth of reaming displacements compared to the manual technique (0.8 mm, p=0.051) but did when compared to PSI (0.8 mm, p=0.036).</p><p><strong>Conclusions: </strong>Glenoid preparation using a robotic arm with an end-effector burr and haptic boundaries was significantly better in its ability to execute a preoperatively planned implant position than manual preparation in 4 of 5 glenoid metrics examined and was significantly better than PSI in 4 of 5 glenoid metrics.</p>","PeriodicalId":50051,"journal":{"name":"Journal of Shoulder and Elbow Surgery","volume":" ","pages":""},"PeriodicalIF":2.9000,"publicationDate":"2025-01-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Shoulder and Elbow Surgery","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1016/j.jse.2024.12.007","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Precise and accurate glenoid preparation is important for the success of shoulder arthroplasty. Despite advancements in preoperative planning software and enabling technologies, most surgeons execute the procedure manually. Patient-specific instrumentation (PSI) facilitates accurate glenoid guide pin placement for cannulated reaming; however, few commercially available systems offer depth of reaming control. Robotic-arm assisted bone preparation has gained popularity in knee and hip arthroplasty, but at the present time there is limited information available on the use of robotics for shoulder arthroplasty. The purpose of this study was to compare glenoid preparation and final implant position using three techniques: manual, manual assisted with PSI, and robotic arm assisted bone preparation.

Methods: Six shoulder surgeons participated in this study utilizing three preparation techniques: (1) manual reaming, (2) manual reaming over a pin inserted using PSI, and (3) preparation using a robotic arm assist with an end-effector burr and haptic boundaries. Each surgeon randomly conducted each technique on 2 separate Bone Matrix glenoid models, for a total of 36 glenoid models tested. To compare the techniques, the final prepared Bone Matrix models underwent a CT scan with 3D virtual model generation. The prepared 3D virtual glenoid models were then compared to the preoperatively planned models. Parameters compared included deviations in version, inclination, anterior-posterior (AP) translation, superior-inferior (SI) translation, and depth of reaming.

Results: Regarding glenoid version with values reported as mean deviations from the preoperative plan, the robotic-assisted technique (1°) was significantly better than manual (9°, p<0.001) and PSI (4°, p<0.001) techniques at executing the preoperative plan. Regarding inclination, the robotic-assisted technique (2°) was significantly better than manual (9°, p=0.003) but not significantly different than PSI (3°, p=0.211). The robotic-arm technique, with AP translation, resulted in significantly lower mean displacements (0.3mm) than the manual technique (2mm, p=0.001) and the PSI technique (2mm, p=0.002). With SI translation, the robotic-arm assisted technique (0.7mm) resulted in significantly lower mean displacements as compared to the manual (2mm, p=0.007) and PSI (1mm, p=0.011). The robotic-arm assisted technique (0.4 mm) did not result in significantly lower mean depth of reaming displacements compared to the manual technique (0.8 mm, p=0.051) but did when compared to PSI (0.8 mm, p=0.036).

Conclusions: Glenoid preparation using a robotic arm with an end-effector burr and haptic boundaries was significantly better in its ability to execute a preoperatively planned implant position than manual preparation in 4 of 5 glenoid metrics examined and was significantly better than PSI in 4 of 5 glenoid metrics.

求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
6.50
自引率
23.30%
发文量
604
审稿时长
11.2 weeks
期刊介绍: The official publication for eight leading specialty organizations, this authoritative journal is the only publication to focus exclusively on medical, surgical, and physical techniques for treating injury/disease of the upper extremity, including the shoulder girdle, arm, and elbow. Clinically oriented and peer-reviewed, the Journal provides an international forum for the exchange of information on new techniques, instruments, and materials. Journal of Shoulder and Elbow Surgery features vivid photos, professional illustrations, and explicit diagrams that demonstrate surgical approaches and depict implant devices. Topics covered include fractures, dislocations, diseases and injuries of the rotator cuff, imaging techniques, arthritis, arthroscopy, arthroplasty, and rehabilitation.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信