How to correct QT interval after cardiac resynchronisation therapy.

IF 1.3 4区 医学 Q3 CARDIAC & CARDIOVASCULAR SYSTEMS
Amin Esmailian, Colin Machado, Hui Chen Han, Jeffrey Alison, Mohammad Alasti
{"title":"How to correct QT interval after cardiac resynchronisation therapy.","authors":"Amin Esmailian, Colin Machado, Hui Chen Han, Jeffrey Alison, Mohammad Alasti","doi":"10.1016/j.jelectrocard.2025.153881","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>This study evaluates various formulae used to correct the QT interval in patients with wide QRS complexes to calculate corrected QT (QTc) following Cardiac Resynchronisation Therapy (CRT).</p><p><strong>Methods: </strong>We included patients with severe heart failure and left bundle branch block, presenting with a QRS duration of at least 120 milliseconds, who underwent successful CRT implantation. Patients were excluded if they had non-lateral left ventricular lead placement, metabolic disorders, atrial fibrillation, atrial tachycardia, or high-degree atrioventricular block prior to implantation. QT intervals were measured pre- and post-implantation and corrected for QRS duration and heart rate using the Boggosian, Wand, Rautaharju, Yankelson, Tang & Rabkin, Bazett, Framingham, Hodges and Fredericia formulae.</p><p><strong>Results: </strong>A total of 51 patients met the study criteria. After CRT, the QRS duration significantly decreased from 189.68 ± 18.06 milliseconds to 165.25 ± 18.78 milliseconds. However, the QT interval corrected using Bazett's formula showed no significant change (522.30 ± 33.37 milliseconds versus 524.06 ± 36.52 milliseconds). Among the various correction methods, the combination of the Bogossian formula (for QRS duration) followed by the Hodges formula (for heart rate), or the Rautaharju formula followed by the Fredericia formula, produced comparable QT intervals. Similarly, correcting heart rate with the Fredericia formula followed by QRS correction with the Rautaharju formula yielded consistent results.</p><p><strong>Conclusion: </strong>Our findings indicate that different formulae for correcting QT intervals for heart rate and QRS duration may yield varying results. Notably, the use of the Bogossian formula followed by the Hodges formula, or the combination of the Rautaharju and Fredericia formulae, produces relatively consistent QT intervals before and after CRT. Further research is needed to validate these findings.</p>","PeriodicalId":15606,"journal":{"name":"Journal of electrocardiology","volume":"89 ","pages":"153881"},"PeriodicalIF":1.3000,"publicationDate":"2025-01-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of electrocardiology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1016/j.jelectrocard.2025.153881","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0

Abstract

Introduction: This study evaluates various formulae used to correct the QT interval in patients with wide QRS complexes to calculate corrected QT (QTc) following Cardiac Resynchronisation Therapy (CRT).

Methods: We included patients with severe heart failure and left bundle branch block, presenting with a QRS duration of at least 120 milliseconds, who underwent successful CRT implantation. Patients were excluded if they had non-lateral left ventricular lead placement, metabolic disorders, atrial fibrillation, atrial tachycardia, or high-degree atrioventricular block prior to implantation. QT intervals were measured pre- and post-implantation and corrected for QRS duration and heart rate using the Boggosian, Wand, Rautaharju, Yankelson, Tang & Rabkin, Bazett, Framingham, Hodges and Fredericia formulae.

Results: A total of 51 patients met the study criteria. After CRT, the QRS duration significantly decreased from 189.68 ± 18.06 milliseconds to 165.25 ± 18.78 milliseconds. However, the QT interval corrected using Bazett's formula showed no significant change (522.30 ± 33.37 milliseconds versus 524.06 ± 36.52 milliseconds). Among the various correction methods, the combination of the Bogossian formula (for QRS duration) followed by the Hodges formula (for heart rate), or the Rautaharju formula followed by the Fredericia formula, produced comparable QT intervals. Similarly, correcting heart rate with the Fredericia formula followed by QRS correction with the Rautaharju formula yielded consistent results.

Conclusion: Our findings indicate that different formulae for correcting QT intervals for heart rate and QRS duration may yield varying results. Notably, the use of the Bogossian formula followed by the Hodges formula, or the combination of the Rautaharju and Fredericia formulae, produces relatively consistent QT intervals before and after CRT. Further research is needed to validate these findings.

求助全文
约1分钟内获得全文 求助全文
来源期刊
Journal of electrocardiology
Journal of electrocardiology 医学-心血管系统
CiteScore
2.70
自引率
7.70%
发文量
152
审稿时长
38 days
期刊介绍: The Journal of Electrocardiology is devoted exclusively to clinical and experimental studies of the electrical activities of the heart. It seeks to contribute significantly to the accuracy of diagnosis and prognosis and the effective treatment, prevention, or delay of heart disease. Editorial contents include electrocardiography, vectorcardiography, arrhythmias, membrane action potential, cardiac pacing, monitoring defibrillation, instrumentation, drug effects, and computer applications.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信