{"title":"Effect of modeling liquid application on color stability and surface roughness of single-shade composites.","authors":"Melek Güven Bekdaş, Ihsan Hubbezoglu","doi":"10.1186/s12903-025-05502-8","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>The objective of this study was to examine the effects of modeling liquid application on the color stability and surface roughness of single-shade composites.</p><p><strong>Materials and methods: </strong>Single-shade composites were divided into 4 main groups according to their contents. A total of 64 disc-shaped samples (8 × 2 mm) were prepared, 16 in each group, by using Teflon molds. The samples were divided into two subgroups on the basis of the application of a modeling liquid. After the initial color and roughness measurements, the samples were immersed in coffee for 12 days. Color changes were assessed via a spectrophotometer and ΔE values were calculated via the CIELAB formula. The surface roughness (Ra) was measured via a profilometer. The data were subjected to statistical analysis via two-way analysis of variance and Tukey's test to examine pairwise differences at a significance level of 0.05.</p><p><strong>Results: </strong>The application of modeling liquid reduced discoloration in Charisma Diamond One (CDO) and Vittra APS Unique (VUA), whereas it slightly increased discoloration in Omnichroma (OMN) and Zenchroma (ZNC). However, only the changes in CDO were statistically significant (p < 0.05). Among the composite control groups baseline and after the coloring procedures, the highest surface roughness degree was observed in the CDO group, while the lowest surface roughness degree was observed in the OMN and ZNC groups (p < 0.05), and the differences between them were found to be significant (p > 0.05). The surface roughness and color changes approached the mean values in the subgroups where the modeling liquid was applied, and there was no significant difference between them (p > 0.05). The application of modeling liquid was observed to reduce the variation in initial roughness among the composites, bringing their roughness values closer to an average range (0.26-0.34).</p><p><strong>Conclusion: </strong>Modeling liquid application increased roughness and discoloration in composites with initially low surface roughness (OMN and ZNC) while reducing roughness and discoloration in composites with initially high surface roughness (VUA and CDO).</p><p><strong>Clinical relevance: </strong>Modeling liquid application should be approached more cautiously in composites with high polishability, despite contributing to clinical use in composites with high roughness values.</p>","PeriodicalId":9072,"journal":{"name":"BMC Oral Health","volume":"25 1","pages":"120"},"PeriodicalIF":2.6000,"publicationDate":"2025-01-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11755945/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"BMC Oral Health","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1186/s12903-025-05502-8","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

Abstract

Objectives: The objective of this study was to examine the effects of modeling liquid application on the color stability and surface roughness of single-shade composites.

Materials and methods: Single-shade composites were divided into 4 main groups according to their contents. A total of 64 disc-shaped samples (8 × 2 mm) were prepared, 16 in each group, by using Teflon molds. The samples were divided into two subgroups on the basis of the application of a modeling liquid. After the initial color and roughness measurements, the samples were immersed in coffee for 12 days. Color changes were assessed via a spectrophotometer and ΔE values were calculated via the CIELAB formula. The surface roughness (Ra) was measured via a profilometer. The data were subjected to statistical analysis via two-way analysis of variance and Tukey's test to examine pairwise differences at a significance level of 0.05.

Results: The application of modeling liquid reduced discoloration in Charisma Diamond One (CDO) and Vittra APS Unique (VUA), whereas it slightly increased discoloration in Omnichroma (OMN) and Zenchroma (ZNC). However, only the changes in CDO were statistically significant (p < 0.05). Among the composite control groups baseline and after the coloring procedures, the highest surface roughness degree was observed in the CDO group, while the lowest surface roughness degree was observed in the OMN and ZNC groups (p < 0.05), and the differences between them were found to be significant (p > 0.05). The surface roughness and color changes approached the mean values in the subgroups where the modeling liquid was applied, and there was no significant difference between them (p > 0.05). The application of modeling liquid was observed to reduce the variation in initial roughness among the composites, bringing their roughness values closer to an average range (0.26-0.34).

Conclusion: Modeling liquid application increased roughness and discoloration in composites with initially low surface roughness (OMN and ZNC) while reducing roughness and discoloration in composites with initially high surface roughness (VUA and CDO).

Clinical relevance: Modeling liquid application should be approached more cautiously in composites with high polishability, despite contributing to clinical use in composites with high roughness values.

求助全文
约1分钟内获得全文 求助全文
来源期刊
BMC Oral Health
BMC Oral Health DENTISTRY, ORAL SURGERY & MEDICINE-
CiteScore
3.90
自引率
6.90%
发文量
481
审稿时长
6-12 weeks
期刊介绍: BMC Oral Health is an open access, peer-reviewed journal that considers articles on all aspects of the prevention, diagnosis and management of disorders of the mouth, teeth and gums, as well as related molecular genetics, pathophysiology, and epidemiology.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信