Anterior chamber morphological and refractive outcomes following phacoemulsification in pseudoexfoliative eyes: A case-control study.

IF 1.4 4区 医学 Q3 OPHTHALMOLOGY
Bruna Cunha, Pedro Gil, Catarina Barão, Diogo Hipólito-Fernandes, Vítor Maduro, João Feijão, Nuno Alves
{"title":"Anterior chamber morphological and refractive outcomes following phacoemulsification in pseudoexfoliative eyes: A case-control study.","authors":"Bruna Cunha, Pedro Gil, Catarina Barão, Diogo Hipólito-Fernandes, Vítor Maduro, João Feijão, Nuno Alves","doi":"10.1177/11206721241310345","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To compare changes in angle morphology, anterior chamber depth (ACD) and refractive prediction error (PE) after phacoemulsification between pseudoexfoliative (PEX) and non-PEX eyes.</p><p><strong>Methods: </strong>Prospective case-control study of eyes submitted to cataract surgery. Biometric data and angle parameters - Anterior Chamber Angle (ACA), Angle Opening Distance (AOD), Scleral Spur Angles (SSA) and Trabecular Iris Space Area (TISA) - were measured preoperatively and 1-month postoperatively through swept-source anterior segment optical coherence tomography. Postoperative refractive prediction error (PE) was calculated using an optimized A-constant and the Kane formula.</p><p><strong>Results: </strong>Sixty eyes (30 PEX and 30 non-PEX) of 60 patients were included. Preoperative angle analysis revealed a lower ACA, AOD, SSA and TISA in PEX group (<i>p</i> < 0.05), without biometric differences (<i>p</i> > 0.05). A tendency for a higher magnitude of morphometric angle changes in PEX eyes was observed, with a superior increase of SSA at 500 µm (0°) and TISA at 750 µm (0°) (<i>p</i> = 0.030 and <i>p</i> = 0.041, respectively). The anterior chamber deepened in both groups (<i>p</i> = 0.01), with arithmetic and percentile change being higher in PEX group (<i>p</i> = 0.017 and <i>p</i> = 0.047, respectively). A significant PE hyperopic shift was observed (<i>p</i> = 0.035) only in PEX group.</p><p><strong>Conclusions: </strong>Pseudoexfoliative eyes with cataract have narrower angles, revealing a tendency for higher angle opening after surgery, along with an increased ACD deepening compared to non-PEX eyes, which may be explained by PEX-associated zonular laxity. Moreover, a significant hyperopic shift was observed in PEX eyes, a relevant fact to take into consideration when selecting intraocular lens power.</p>","PeriodicalId":12000,"journal":{"name":"European Journal of Ophthalmology","volume":" ","pages":"11206721241310345"},"PeriodicalIF":1.4000,"publicationDate":"2025-01-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"European Journal of Ophthalmology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1177/11206721241310345","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: To compare changes in angle morphology, anterior chamber depth (ACD) and refractive prediction error (PE) after phacoemulsification between pseudoexfoliative (PEX) and non-PEX eyes.

Methods: Prospective case-control study of eyes submitted to cataract surgery. Biometric data and angle parameters - Anterior Chamber Angle (ACA), Angle Opening Distance (AOD), Scleral Spur Angles (SSA) and Trabecular Iris Space Area (TISA) - were measured preoperatively and 1-month postoperatively through swept-source anterior segment optical coherence tomography. Postoperative refractive prediction error (PE) was calculated using an optimized A-constant and the Kane formula.

Results: Sixty eyes (30 PEX and 30 non-PEX) of 60 patients were included. Preoperative angle analysis revealed a lower ACA, AOD, SSA and TISA in PEX group (p < 0.05), without biometric differences (p > 0.05). A tendency for a higher magnitude of morphometric angle changes in PEX eyes was observed, with a superior increase of SSA at 500 µm (0°) and TISA at 750 µm (0°) (p = 0.030 and p = 0.041, respectively). The anterior chamber deepened in both groups (p = 0.01), with arithmetic and percentile change being higher in PEX group (p = 0.017 and p = 0.047, respectively). A significant PE hyperopic shift was observed (p = 0.035) only in PEX group.

Conclusions: Pseudoexfoliative eyes with cataract have narrower angles, revealing a tendency for higher angle opening after surgery, along with an increased ACD deepening compared to non-PEX eyes, which may be explained by PEX-associated zonular laxity. Moreover, a significant hyperopic shift was observed in PEX eyes, a relevant fact to take into consideration when selecting intraocular lens power.

求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
3.60
自引率
0.00%
发文量
372
审稿时长
3-8 weeks
期刊介绍: The European Journal of Ophthalmology was founded in 1991 and is issued in print bi-monthly. It publishes only peer-reviewed original research reporting clinical observations and laboratory investigations with clinical relevance focusing on new diagnostic and surgical techniques, instrument and therapy updates, results of clinical trials and research findings.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信