Clinical Application of the Fetal HQ Technique in the Evaluation of Normal Fetal Cardiac Function at Different Gestational Weeks.

IF 1.6 4区 医学 Q3 CARDIAC & CARDIOVASCULAR SYSTEMS
Xiao-Rong Su, Ai-Lin Wang, Hong-Xia Tie, Wen-Rui Wu, Wen-Dong Zhang, Ke-Xiong Niu, Tian-Gang Li
{"title":"Clinical Application of the Fetal HQ Technique in the Evaluation of Normal Fetal Cardiac Function at Different Gestational Weeks.","authors":"Xiao-Rong Su, Ai-Lin Wang, Hong-Xia Tie, Wen-Rui Wu, Wen-Dong Zhang, Ke-Xiong Niu, Tian-Gang Li","doi":"10.1111/echo.70078","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>To investigate the clinical value of fetal heart quantification (fetal HQ) in the evaluation of normal fetal heart size, morphology, and cardiac function at different gestational weeks.</p><p><strong>Materials and methods: </strong>A total of 101 pregnant women diagnosed with a healthy fetus by fetal echocardiography from September 2021 to December 2023 were selected and classified into four different periods of gestational weeks: 20-28 weeks (25 cases), 29-32 weeks (26 cases), 33-36 weeks (26 cases), and 37-40 weeks (24 cases). Quantitative analyses were performed by automatically tracking the endocardium using fetal HQ software that comes with the Voluson E10 from GE. To investigate the correlation between four-chambered vesicle length end-diastolic (4CV LED), four-chambered vesicle transverse width end-diastolic (4CV TWED), global sphericity index (GSI), ejection fraction (EF), stroke volume (SV), cardiac output (CO), and gestation age (GA), and the variability of normal fetal cardiac morphology and cardiac function at different gestational weeks.</p><p><strong>Results: </strong>A statistically significant difference was observed between 4CV LED and 4CV TWED in normal fetuses at different gestational weeks (p < 0.05), which exhibited a positive correlation with gestational week. Conversely, no significant correlation was identified between GSI and gestational week (p > 0.05). The mean GSI of 101 normal fetuses was found to be 1.25 ± 0.09. A comparative analysis of EF, SV, and CO in normal fetuses at different gestational weeks revealed statistically significant differences in SV and CO (p < 0.05), which gradually increased with gestational weeks, whereas there was no statistically significant difference in EF (p > 0.05).</p><p><strong>Conclusions: </strong>Fetal HQ represents a straightforward and dependable method for evaluating GSI and 24-segment SI of the left and right ventricles, which can provide a certain theoretical basis for the clinical quantitative evaluation of fetal cardiac geometry and cardiac function.</p>","PeriodicalId":50558,"journal":{"name":"Echocardiography-A Journal of Cardiovascular Ultrasound and Allied Techniques","volume":"42 1","pages":"e70078"},"PeriodicalIF":1.6000,"publicationDate":"2025-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Echocardiography-A Journal of Cardiovascular Ultrasound and Allied Techniques","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1111/echo.70078","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0

Abstract

Objectives: To investigate the clinical value of fetal heart quantification (fetal HQ) in the evaluation of normal fetal heart size, morphology, and cardiac function at different gestational weeks.

Materials and methods: A total of 101 pregnant women diagnosed with a healthy fetus by fetal echocardiography from September 2021 to December 2023 were selected and classified into four different periods of gestational weeks: 20-28 weeks (25 cases), 29-32 weeks (26 cases), 33-36 weeks (26 cases), and 37-40 weeks (24 cases). Quantitative analyses were performed by automatically tracking the endocardium using fetal HQ software that comes with the Voluson E10 from GE. To investigate the correlation between four-chambered vesicle length end-diastolic (4CV LED), four-chambered vesicle transverse width end-diastolic (4CV TWED), global sphericity index (GSI), ejection fraction (EF), stroke volume (SV), cardiac output (CO), and gestation age (GA), and the variability of normal fetal cardiac morphology and cardiac function at different gestational weeks.

Results: A statistically significant difference was observed between 4CV LED and 4CV TWED in normal fetuses at different gestational weeks (p < 0.05), which exhibited a positive correlation with gestational week. Conversely, no significant correlation was identified between GSI and gestational week (p > 0.05). The mean GSI of 101 normal fetuses was found to be 1.25 ± 0.09. A comparative analysis of EF, SV, and CO in normal fetuses at different gestational weeks revealed statistically significant differences in SV and CO (p < 0.05), which gradually increased with gestational weeks, whereas there was no statistically significant difference in EF (p > 0.05).

Conclusions: Fetal HQ represents a straightforward and dependable method for evaluating GSI and 24-segment SI of the left and right ventricles, which can provide a certain theoretical basis for the clinical quantitative evaluation of fetal cardiac geometry and cardiac function.

胎儿HQ技术在不同孕周正常胎儿心功能评价中的临床应用。
目的:探讨胎儿心脏定量(fetal heart quantification,胎儿HQ)在评估不同孕周正常胎儿心脏大小、形态及心功能方面的临床价值。材料与方法:选取2021年9月至2023年12月经胎儿超声心动图诊断为胎儿健康的孕妇101例,将其分为孕周20-28周(25例)、29-32周(26例)、33-36周(26例)、37-40周(24例)4个不同时期。使用通用电气公司的Voluson E10附带的胎儿HQ软件自动跟踪心内膜进行定量分析。探讨四室囊泡舒张末期长度(4CV LED)、四室囊泡舒张末期横向宽度(4CV TWED)、全球度指数(GSI)、射血分数(EF)、搏量(SV)、心输出量(CO)、胎龄(GA)与正常胎心形态和心功能在不同孕周的变异性的相关性。结果:正常胎儿不同孕周4CV LED与4CV TWED差异有统计学意义(p < 0.05),且与孕周呈正相关。相反,GSI与妊娠周之间没有显著相关性(p < 0.05)。101例正常胎儿GSI平均值为1.25±0.09。不同孕周正常胎儿EF、SV、CO比较,SV、CO差异有统计学意义(p < 0.05),随孕周增加逐渐升高,EF差异无统计学意义(p < 0.05)。结论:胎儿HQ为评价左、右心室GSI及24段SI提供了一种直观、可靠的方法,可为临床定量评价胎儿心脏几何形态及心功能提供一定的理论依据。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
2.40
自引率
6.70%
发文量
211
审稿时长
3-6 weeks
期刊介绍: Echocardiography: A Journal of Cardiovascular Ultrasound and Allied Techniques is the official publication of the International Society of Cardiovascular Ultrasound. Widely recognized for its comprehensive peer-reviewed articles, case studies, original research, and reviews by international authors. Echocardiography keeps its readership of echocardiographers, ultrasound specialists, and cardiologists well informed of the latest developments in the field.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信