Establishing Decisional Cutoff Values of Neurofilament Light Chains in Cerebrospinal Fluid Measured by Fully Automated Chemiluminescent Enzyme Immunoassay.

IF 2.6 4区 医学 Q2 MEDICAL LABORATORY TECHNOLOGY
Luisa Agnello, Caterina Maria Gambino, Fabio Del Ben, Anna Maria Ciaccio, Concetta Scazzone, Marcello Ciaccio
{"title":"Establishing Decisional Cutoff Values of Neurofilament Light Chains in Cerebrospinal Fluid Measured by Fully Automated Chemiluminescent Enzyme Immunoassay.","authors":"Luisa Agnello, Caterina Maria Gambino, Fabio Del Ben, Anna Maria Ciaccio, Concetta Scazzone, Marcello Ciaccio","doi":"10.1002/jcla.25152","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>Neurofilament light chain (NfL) is one of the most important biomarkers in the field of clinical neurochemistry. Several analytical methods have been developed in the last decade. Recently, Fujirebio introduced a ready-to-use assay kit for measuring NfL levels in the cerebrospinal fluid (CSF) on the fully automated LUMIPULSE G System. In this study, we established the decisional cutoffs for CSF NfL.</p><p><strong>Materials and methods: </strong>We performed a retrospective observational study including patients with cognitive decline. CSF NfL levels were measured by two analytical methods: the NF-light ELISA kit (UmanDiagnostics) and the Lumipulse G1200 fully automated system (Fujirebio). We calculated the cutoffs for the Lumipulse, starting from the consolidated cutoffs of the ELISA method for each age and using the equation obtained by the regression analysis.</p><p><strong>Results: </strong>The study population consisted of 100 patients with cognitive decline. The median levels of CSF NfL measured by Lumipulse and ELISA were 776.5 ± 772.6 pg/mL and 473.5 ± 443.5 pg/mL, respectively, significantly different (p < 0.001). The Spearman's rank correlation coefficient was 0.962, indicating a robust positive correlation between the two measurement methods. The equation derived from the Passing-Bablok regression analysis was CSF CLEIA = -61.16 + 1.83 × CSF ELISA. Based on this equation, we defined the decisional cutoff values.</p><p><strong>Conclusions: </strong>Decisional cutoffs are fundamental tools for guiding clinicians to use biomarkers' results and interpretation appropriately. This is the first study establishing the decisional cutoff value of NfL measured by Lumipulse, a fully automated platform widely used in clinical laboratories.</p>","PeriodicalId":15509,"journal":{"name":"Journal of Clinical Laboratory Analysis","volume":" ","pages":"e25152"},"PeriodicalIF":2.6000,"publicationDate":"2025-01-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Clinical Laboratory Analysis","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1002/jcla.25152","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"MEDICAL LABORATORY TECHNOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Introduction: Neurofilament light chain (NfL) is one of the most important biomarkers in the field of clinical neurochemistry. Several analytical methods have been developed in the last decade. Recently, Fujirebio introduced a ready-to-use assay kit for measuring NfL levels in the cerebrospinal fluid (CSF) on the fully automated LUMIPULSE G System. In this study, we established the decisional cutoffs for CSF NfL.

Materials and methods: We performed a retrospective observational study including patients with cognitive decline. CSF NfL levels were measured by two analytical methods: the NF-light ELISA kit (UmanDiagnostics) and the Lumipulse G1200 fully automated system (Fujirebio). We calculated the cutoffs for the Lumipulse, starting from the consolidated cutoffs of the ELISA method for each age and using the equation obtained by the regression analysis.

Results: The study population consisted of 100 patients with cognitive decline. The median levels of CSF NfL measured by Lumipulse and ELISA were 776.5 ± 772.6 pg/mL and 473.5 ± 443.5 pg/mL, respectively, significantly different (p < 0.001). The Spearman's rank correlation coefficient was 0.962, indicating a robust positive correlation between the two measurement methods. The equation derived from the Passing-Bablok regression analysis was CSF CLEIA = -61.16 + 1.83 × CSF ELISA. Based on this equation, we defined the decisional cutoff values.

Conclusions: Decisional cutoffs are fundamental tools for guiding clinicians to use biomarkers' results and interpretation appropriately. This is the first study establishing the decisional cutoff value of NfL measured by Lumipulse, a fully automated platform widely used in clinical laboratories.

求助全文
约1分钟内获得全文 求助全文
来源期刊
Journal of Clinical Laboratory Analysis
Journal of Clinical Laboratory Analysis 医学-医学实验技术
CiteScore
5.60
自引率
7.40%
发文量
584
审稿时长
6-12 weeks
期刊介绍: Journal of Clinical Laboratory Analysis publishes original articles on newly developing modes of technology and laboratory assays, with emphasis on their application in current and future clinical laboratory testing. This includes reports from the following fields: immunochemistry and toxicology, hematology and hematopathology, immunopathology, molecular diagnostics, microbiology, genetic testing, immunohematology, and clinical chemistry.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信