Evaluating the efficacy of cavity disinfection using methylene blue dye with 660-nm diode laser on primary molars: An in vivo study.

Mitaj Pandharinath Anvekar, Shruti Girish Virupaxi, Chandrashekar Yavagal, Sadanand Kulkarni, Ramya Pai, Viplavi Vijaysinh Chavan Patil
{"title":"Evaluating the efficacy of cavity disinfection using methylene blue dye with 660-nm diode laser on primary molars: An in vivo study.","authors":"Mitaj Pandharinath Anvekar, Shruti Girish Virupaxi, Chandrashekar Yavagal, Sadanand Kulkarni, Ramya Pai, Viplavi Vijaysinh Chavan Patil","doi":"10.4103/jisppd.jisppd_258_24","DOIUrl":null,"url":null,"abstract":"<p><strong>Background and objectives: </strong>The purpose of this study was to evaluate the antimicrobial activity of methylene blue dye with 660-nm diode laser in cavity disinfection and to compare the total bacterial count in dentinal samples preexcavation, postexcavation, and postdisinfection. The study design was experimental in vivo.</p><p><strong>Materials and methods: </strong>Fifteen children aged 5-12 years with 15 primary molars requiring atraumatic restorative treatment (ART) were selected. Dentinal samples were collected from the carious tooth with a sterile spoon excavator three times, i.e., before caries excavation (preexcavation), after hand excavation of caries (postexcavation), and after doing laser photodynamic therapy with methylene blue dye and 660-nm diode laser (postdisinfection) and sent for microbiological analysis. The samples were transported in reduced transport fluid. The total bacterial count was carried out by an experienced microbiologist immediately after reporting.</p><p><strong>Results: </strong>A significant number of bacteria was present after hand excavation of caries using ART. The bacterial count significantly reduced postlaser disinfection. The total viable bacterial count was reduced to 87.17% with hand excavation of caries, whereas it was reduced to 98.59% postlaser disinfection using methylene blue dye with 660-nm diode laser.</p><p><strong>Conclusion: </strong>It was seen that ART cannot eliminate all the microorganisms. Methylene blue dye with a 660-nm diode laser was able to reduce the total bacterial count and can be effectively used as an antimicrobial cavity disinfectant.</p>","PeriodicalId":101311,"journal":{"name":"Journal of the Indian Society of Pedodontics and Preventive Dentistry","volume":"42 4","pages":"280-285"},"PeriodicalIF":0.0000,"publicationDate":"2024-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of the Indian Society of Pedodontics and Preventive Dentistry","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4103/jisppd.jisppd_258_24","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/1/11 0:00:00","PubModel":"Epub","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Background and objectives: The purpose of this study was to evaluate the antimicrobial activity of methylene blue dye with 660-nm diode laser in cavity disinfection and to compare the total bacterial count in dentinal samples preexcavation, postexcavation, and postdisinfection. The study design was experimental in vivo.

Materials and methods: Fifteen children aged 5-12 years with 15 primary molars requiring atraumatic restorative treatment (ART) were selected. Dentinal samples were collected from the carious tooth with a sterile spoon excavator three times, i.e., before caries excavation (preexcavation), after hand excavation of caries (postexcavation), and after doing laser photodynamic therapy with methylene blue dye and 660-nm diode laser (postdisinfection) and sent for microbiological analysis. The samples were transported in reduced transport fluid. The total bacterial count was carried out by an experienced microbiologist immediately after reporting.

Results: A significant number of bacteria was present after hand excavation of caries using ART. The bacterial count significantly reduced postlaser disinfection. The total viable bacterial count was reduced to 87.17% with hand excavation of caries, whereas it was reduced to 98.59% postlaser disinfection using methylene blue dye with 660-nm diode laser.

Conclusion: It was seen that ART cannot eliminate all the microorganisms. Methylene blue dye with a 660-nm diode laser was able to reduce the total bacterial count and can be effectively used as an antimicrobial cavity disinfectant.

660nm二极管激光亚甲基蓝染料对初生磨牙口腔消毒效果的体内研究
背景与目的:本研究的目的是评价亚甲基蓝染料在660 nm二极管激光口腔消毒中的抗菌活性,并比较牙本质样品在挖掘前、挖掘后和消毒后的细菌总数。研究设计为体内实验。材料与方法:选择15例5 ~ 12岁的儿童,15颗初生磨牙需要非创伤性修复治疗(ART)。用无菌勺形挖掘机采集龋牙体标本,分别在龋洞挖掘前(挖掘前)、手挖龋后(挖掘后)、亚甲基蓝染料和660纳米二极管激光光动力治疗后(消毒后)3次采集,并送微生物学分析。样品在减少的运输流体中运输。报告后立即由经验丰富的微生物学家进行细菌总数计数。结果:手挖龋术后细菌数量明显增多。激光消毒后细菌数量明显减少。用手挖龋可使总活菌数减少87.17%,而用亚甲基蓝染料和660 nm二极管激光消毒可使总活菌数减少98.59%。结论:ART不能消除所有的微生物。亚甲基蓝染料与660纳米二极管激光能够减少细菌总数,可以有效地用作抗菌腔消毒剂。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信