{"title":"Improving Sternal Closure Outcomes in Cardiac Surgery: Polyethylene Suture Tapes vs. Steel Wires.","authors":"Zain Khalpey, Ujjawal Aditya Kumar, Usman Aslam, Tyler Phillips, Zacharya Khalpey, Anthony Cooper, Robert Riley","doi":"10.3390/jcm14010277","DOIUrl":null,"url":null,"abstract":"<p><p><b>Background:</b> Steel wires are often inadequate for sternal closure for patients at high risk of sternal complications. This study compares a novel sternal closure system to conventional steel wires to assess its potential to reduce sternal complication rates and improve clinical outcomes. <b>Methods:</b> A retrospective study was conducted on 300 consecutive patients undergoing cardiac surgery via median sternotomy. A total of 150 patients underwent steel wire sternal closure, while 150 underwent suture tape closure. Preoperative, intraoperative, and postoperative data were collected and analyzed for both groups. <b>Results:</b> Rates of sternal wound infections (1% vs. 5%, <i>p</i> = 0.0363) and sternal dehiscence (0% vs. 5%, <i>p</i> = 0.0297) were lower in the suture tape group. Suture tape patients had significantly less pain at 14 and 30 days (<i>p</i> = 0.0002 and 0.0071). The requirement for sternal protection adjuncts was eliminated with suture tape closure. Sternal closure time was significantly shorter in the suture tape group (11 vs. 19 min, <i>p</i> < 0.0001). <b>Conclusions:</b> Suture tapes proved safe, feasible, and effective for sternal closure, demonstrating significant advantages for sternal closure over steel wires, with reduced rates of sternal dehiscence, infection, postoperative incisional pain, and closure time. These superior outcomes and the elimination of sternal protection adjuncts can potentially reduce healthcare costs. Our experiences suggest that this novel sternal closure system has significant potential, with larger prospective studies warranted to optimize sternal closure strategies.</p>","PeriodicalId":15533,"journal":{"name":"Journal of Clinical Medicine","volume":"14 1","pages":""},"PeriodicalIF":3.0000,"publicationDate":"2025-01-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11720976/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Clinical Medicine","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.3390/jcm14010277","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"MEDICINE, GENERAL & INTERNAL","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Steel wires are often inadequate for sternal closure for patients at high risk of sternal complications. This study compares a novel sternal closure system to conventional steel wires to assess its potential to reduce sternal complication rates and improve clinical outcomes. Methods: A retrospective study was conducted on 300 consecutive patients undergoing cardiac surgery via median sternotomy. A total of 150 patients underwent steel wire sternal closure, while 150 underwent suture tape closure. Preoperative, intraoperative, and postoperative data were collected and analyzed for both groups. Results: Rates of sternal wound infections (1% vs. 5%, p = 0.0363) and sternal dehiscence (0% vs. 5%, p = 0.0297) were lower in the suture tape group. Suture tape patients had significantly less pain at 14 and 30 days (p = 0.0002 and 0.0071). The requirement for sternal protection adjuncts was eliminated with suture tape closure. Sternal closure time was significantly shorter in the suture tape group (11 vs. 19 min, p < 0.0001). Conclusions: Suture tapes proved safe, feasible, and effective for sternal closure, demonstrating significant advantages for sternal closure over steel wires, with reduced rates of sternal dehiscence, infection, postoperative incisional pain, and closure time. These superior outcomes and the elimination of sternal protection adjuncts can potentially reduce healthcare costs. Our experiences suggest that this novel sternal closure system has significant potential, with larger prospective studies warranted to optimize sternal closure strategies.

求助全文
约1分钟内获得全文 求助全文
来源期刊
Journal of Clinical Medicine
Journal of Clinical Medicine MEDICINE, GENERAL & INTERNAL-
CiteScore
5.70
自引率
7.70%
发文量
6468
审稿时长
16.32 days
期刊介绍: Journal of Clinical Medicine (ISSN 2077-0383), is an international scientific open access journal, providing a platform for advances in health care/clinical practices, the study of direct observation of patients and general medical research. This multi-disciplinary journal is aimed at a wide audience of medical researchers and healthcare professionals. Unique features of this journal: manuscripts regarding original research and ideas will be particularly welcomed.JCM also accepts reviews, communications, and short notes. There is no limit to publication length: our aim is to encourage scientists to publish their experimental and theoretical results in as much detail as possible.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信