Radiation Safety Assessment of 177Lu-DOTATATE Intra-arterial Peptide Receptor Therapy (PRRT).

IF 0.4 Q4 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
Indian Journal of Nuclear Medicine Pub Date : 2024-07-01 Epub Date: 2024-11-18 DOI:10.4103/ijnm.ijnm_88_23
Manoj Kumar Hariram Chauhan, Ashish Kumar Jha, Sneha Mithun, Rutuja Dasharath Parab, Pooja Dwivedi, Ameya D Puranik, Kunal Bharat Gala, Nitin Sudhakar Shetye, Suyash Kulkarni, Venkatesh Rangarajan
{"title":"Radiation Safety Assessment of 177Lu-DOTATATE Intra-arterial Peptide Receptor Therapy (PRRT).","authors":"Manoj Kumar Hariram Chauhan, Ashish Kumar Jha, Sneha Mithun, Rutuja Dasharath Parab, Pooja Dwivedi, Ameya D Puranik, Kunal Bharat Gala, Nitin Sudhakar Shetye, Suyash Kulkarni, Venkatesh Rangarajan","doi":"10.4103/ijnm.ijnm_88_23","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong><sup>177</sup>Lu-DOTATATE peptide receptor therapy (PRRT) is an established treatment for patients suffering from neuroendocrine tumors. In the last few years, intra-arterial PRRT is being considered for patients having liver metastatic disease predominantly. The aim of our study is to measure the radiation doses received by the treating intervention radiologists involved in intra-arterial PRRT treatment using <sup>177</sup>Lu-DOTATATE.</p><p><strong>Materials and methods: </strong>Radiation safety-related data of 31 patients who underwent 177Lu-DOTATATE intra-arterial PRRT treatment were used for this study. The exposure rate was measured at the hand and eye and chest level of treating intervention radiologists continuously from the beginning to the end of the administration. Exposure from the patient at the body surface (at the level of liver, thigh, and extremities) and 1 m from the body surface was measured just after the administration. The mean radiation exposure from the patient at the body surface and 1 m from the body was also calculated.</p><p><strong>Results: </strong>The mean administered activity was found to be 194 (±17) mCi. The mean radiation exposure at the surface at the level of the liver, thigh, and feet and at 1 m from the surface was found to be 100 (±25.11), 9 (±1.27), 5.6 (±0.52), and 5.3± (0.50) μSv/hr, respectively. The mean administration time was found to be 23 ± 5.6 min. The mean radiation dose to the hands, and eyes, of the treating intervention radiologist per procedure, was found to be 6.425 ± 2.75 μSv, 5.43 ± 1.76 μSv and 1-m exposure from the patient was found to be 5.3 ± 0.246 μSv, respectively.</p><p><strong>Conclusion: </strong>Our result shows that the radiation exposure from the patient postadministration is below the permissible limit of discharge. The radiation exposure to the intervention radiologist is also suggestive of a safe procedure to be performed by maintaining the radiation dose well within the permissible limit for radiation professionals.</p>","PeriodicalId":45830,"journal":{"name":"Indian Journal of Nuclear Medicine","volume":"39 4","pages":"254-258"},"PeriodicalIF":0.4000,"publicationDate":"2024-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11708803/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Indian Journal of Nuclear Medicine","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4103/ijnm.ijnm_88_23","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/11/18 0:00:00","PubModel":"Epub","JCR":"Q4","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

Abstract

Objective: 177Lu-DOTATATE peptide receptor therapy (PRRT) is an established treatment for patients suffering from neuroendocrine tumors. In the last few years, intra-arterial PRRT is being considered for patients having liver metastatic disease predominantly. The aim of our study is to measure the radiation doses received by the treating intervention radiologists involved in intra-arterial PRRT treatment using 177Lu-DOTATATE.

Materials and methods: Radiation safety-related data of 31 patients who underwent 177Lu-DOTATATE intra-arterial PRRT treatment were used for this study. The exposure rate was measured at the hand and eye and chest level of treating intervention radiologists continuously from the beginning to the end of the administration. Exposure from the patient at the body surface (at the level of liver, thigh, and extremities) and 1 m from the body surface was measured just after the administration. The mean radiation exposure from the patient at the body surface and 1 m from the body was also calculated.

Results: The mean administered activity was found to be 194 (±17) mCi. The mean radiation exposure at the surface at the level of the liver, thigh, and feet and at 1 m from the surface was found to be 100 (±25.11), 9 (±1.27), 5.6 (±0.52), and 5.3± (0.50) μSv/hr, respectively. The mean administration time was found to be 23 ± 5.6 min. The mean radiation dose to the hands, and eyes, of the treating intervention radiologist per procedure, was found to be 6.425 ± 2.75 μSv, 5.43 ± 1.76 μSv and 1-m exposure from the patient was found to be 5.3 ± 0.246 μSv, respectively.

Conclusion: Our result shows that the radiation exposure from the patient postadministration is below the permissible limit of discharge. The radiation exposure to the intervention radiologist is also suggestive of a safe procedure to be performed by maintaining the radiation dose well within the permissible limit for radiation professionals.

177Lu-DOTATATE动脉内肽受体治疗(PRRT)的放射安全性评价。
目的:177Lu-DOTATATE肽受体治疗(PRRT)是神经内分泌肿瘤的常用治疗方法。在过去的几年中,动脉内PRRT主要用于肝转移性疾病患者。我们研究的目的是测量介入治疗放射科医生使用177Lu-DOTATATE进行动脉内PRRT治疗时所接受的辐射剂量。材料和方法:本研究使用31例接受177Lu-DOTATATE动脉内PRRT治疗的患者的放射安全相关数据。从给药开始至给药结束连续测量介入治疗放射科医师的手、眼和胸部暴露率。在给药后测量患者体表(肝脏、大腿和四肢水平)和体表1 m处的暴露量。同时计算患者体表处和距离身体1 m处的平均辐射暴露量。结果:平均给药活性为194(±17)mCi。肝脏、大腿和足部及距离体表1 m处的平均辐射暴露量分别为100(±25.11)、9(±1.27)、5.6(±0.52)和5.3±(0.50)μSv/hr。平均给药时间为23±5.6 min。介入治疗放射科医师每次手术对手和眼睛的平均辐射剂量分别为6.425±2.75 μSv、5.43±1.76 μSv,患者1 m照射量分别为5.3±0.246 μSv。结论:患者给药后的辐照量低于出院允许限度。对介入放射科医生的辐射暴露也表明,通过将辐射剂量保持在辐射专业人员允许的限度内来执行安全程序。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Indian Journal of Nuclear Medicine
Indian Journal of Nuclear Medicine RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING-
CiteScore
0.70
自引率
0.00%
发文量
46
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信