Application value of CT three-dimensional reconstruction technology in the identification of benign and malignant lung nodules and the characteristics of nodule distribution.

IF 2.9 3区 医学 Q2 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
Guanghai Ji, Fei Liu, Zhiqiang Chen, Jie Peng, Hao Deng, Sheng Xiao, Yun Li
{"title":"Application value of CT three-dimensional reconstruction technology in the identification of benign and malignant lung nodules and the characteristics of nodule distribution.","authors":"Guanghai Ji, Fei Liu, Zhiqiang Chen, Jie Peng, Hao Deng, Sheng Xiao, Yun Li","doi":"10.1186/s12880-024-01505-z","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>The study aimed to evaluate the application value of computed tomography (CT) three-dimensional (3D) reconstruction technology in identifying benign and malignant lung nodules and characterizing the distribution of the nodules.</p><p><strong>Methods: </strong>CT 3D reconstruction was performed for lung nodules. Pathological results were used as the gold standard to compare the detection rates of various lung nodule signs between conventional chest CT scanning and CT 3D reconstruction techniques. Additionally, the differences in mean diffusion coefficient values and partial anisotropy index values between male and female patients were analyzed.</p><p><strong>Results: </strong>Pathologic confirmation identified 30 patients with benign lesions and 45 patients with malignant lesions. CT 3D reconstruction demonstrated higher diagnostic accuracy for lung nodule imaging signs compared to conventional CT scanning (P < 0.05). The mean diffusion coefficient values and partial anisotropy index values were lower in female patients compared to male patients in the lung nodule lesion area, lung perinodular edema area, and normal lung tissue (P < 0.05). Conventional CT scanning showed a benign accuracy rate of 63.33% and a malignant accuracy rate of 60.00%, whereas CT 3D imaging achieved a benign and malignant accuracy rate of 86.67% for both. The accuracy rates for CT 3D imaging were significantly higher than those for conventional CT scanning (P < 0.05).</p><p><strong>Conclusion: </strong>CT 3D imaging technology demonstrates high diagnostic accuracy in differentiating benign from malignant lung nodules.</p>","PeriodicalId":9020,"journal":{"name":"BMC Medical Imaging","volume":"25 1","pages":"7"},"PeriodicalIF":2.9000,"publicationDate":"2025-01-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11702159/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"BMC Medical Imaging","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1186/s12880-024-01505-z","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

Abstract

Objective: The study aimed to evaluate the application value of computed tomography (CT) three-dimensional (3D) reconstruction technology in identifying benign and malignant lung nodules and characterizing the distribution of the nodules.

Methods: CT 3D reconstruction was performed for lung nodules. Pathological results were used as the gold standard to compare the detection rates of various lung nodule signs between conventional chest CT scanning and CT 3D reconstruction techniques. Additionally, the differences in mean diffusion coefficient values and partial anisotropy index values between male and female patients were analyzed.

Results: Pathologic confirmation identified 30 patients with benign lesions and 45 patients with malignant lesions. CT 3D reconstruction demonstrated higher diagnostic accuracy for lung nodule imaging signs compared to conventional CT scanning (P < 0.05). The mean diffusion coefficient values and partial anisotropy index values were lower in female patients compared to male patients in the lung nodule lesion area, lung perinodular edema area, and normal lung tissue (P < 0.05). Conventional CT scanning showed a benign accuracy rate of 63.33% and a malignant accuracy rate of 60.00%, whereas CT 3D imaging achieved a benign and malignant accuracy rate of 86.67% for both. The accuracy rates for CT 3D imaging were significantly higher than those for conventional CT scanning (P < 0.05).

Conclusion: CT 3D imaging technology demonstrates high diagnostic accuracy in differentiating benign from malignant lung nodules.

CT三维重建技术在肺良恶性结节鉴别中的应用价值及结节分布特征
目的:探讨计算机断层扫描(CT)三维重建技术在鉴别肺良恶性结节及结节分布特征中的应用价值。方法:对肺结节进行CT三维重建。以病理结果为金标准,比较常规胸部CT扫描与CT三维重建技术对各种肺结节征象的检出率。分析男女患者的平均扩散系数值和部分各向异性指数值的差异。结果:病理证实良性病变30例,恶性病变45例。结论:CT三维成像技术对肺结节良恶性鉴别具有较高的诊断准确性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
BMC Medical Imaging
BMC Medical Imaging RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING-
CiteScore
4.60
自引率
3.70%
发文量
198
审稿时长
27 weeks
期刊介绍: BMC Medical Imaging is an open access journal publishing original peer-reviewed research articles in the development, evaluation, and use of imaging techniques and image processing tools to diagnose and manage disease.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信