Midterm comparative result of absorbable screws and metal screws in pediatric medial humeral epicondyle fracture.

IF 1.5 4区 医学 Q3 ORTHOPEDICS
Ming Zeng, Keyu Xie, Shu Cao, Jie Wen, Sisi Wang, Sheng Xiao
{"title":"Midterm comparative result of absorbable screws and metal screws in pediatric medial humeral epicondyle fracture.","authors":"Ming Zeng, Keyu Xie, Shu Cao, Jie Wen, Sisi Wang, Sheng Xiao","doi":"10.1016/j.jos.2024.12.004","DOIUrl":null,"url":null,"abstract":"<p><strong>Backgroud: </strong>Medial humeral epicondyle fracture is a prevalent type of upper limb fractures in pediatric patients. This study aims to compare the follow-up clinical results and complications in 30 children with medial epicondyle fractures who were treated with either metal screws or absorbable screws at our hospital.</p><p><strong>Methods: </strong>A retrospective review was conducted on 30 children with medial humeral epicondyle fractures, who were divided into two groups: Metal group (18 children) underwent fixation using metal screws, while Absorbable group (12 children) received absorbable screws between January 2016 and June 2024. We collected the operation time and the length of incision of each patient. All the patients were followed up for over 20 months. Clinical outcomes were assessed and compared using elbow range of motion (ROM), mayo elbow performance score (MEPS) and range of rotation (ROR) during the last follow-up visit. Additionally, pain levels measured by a 10-point visual analog scale (VAS) and complications were duly documented.</p><p><strong>Results: </strong>In terms of operative time, length of incision, and VAS scores, no significant differences were observed (p > 0.05). The patients were followed up at an average of 33.1 months (range, 22-49 months). The mean MEPS were 89.44 ± 3.79 and 89.58 ± 3.34 (p = 0.89), the mean ROM were 122.28 ± 5.87 and 125.1 ± 5.83 (p = 0.27), and the mean ROR were 153.33 ± 5.94 and 155.83 ± 5.15 (p = 0.26) in groups A and B, respectively. In addition, two children in Metal group experienced symptoms of screw stimulation, while Absorbable group did not.</p><p><strong>Conclusion: </strong>The use of absorbable screws in treating pediatric medial epicondyle fractures can yield equivalent therapeutic outcomes to traditional metal screws, obviating the need for subsequent surgical interventions and mitigating complications associated with screw irritation resulting from non-degradable metallic implants.</p>","PeriodicalId":16939,"journal":{"name":"Journal of Orthopaedic Science","volume":" ","pages":""},"PeriodicalIF":1.5000,"publicationDate":"2025-01-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Orthopaedic Science","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1016/j.jos.2024.12.004","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
引用次数: 0

Abstract

Backgroud: Medial humeral epicondyle fracture is a prevalent type of upper limb fractures in pediatric patients. This study aims to compare the follow-up clinical results and complications in 30 children with medial epicondyle fractures who were treated with either metal screws or absorbable screws at our hospital.

Methods: A retrospective review was conducted on 30 children with medial humeral epicondyle fractures, who were divided into two groups: Metal group (18 children) underwent fixation using metal screws, while Absorbable group (12 children) received absorbable screws between January 2016 and June 2024. We collected the operation time and the length of incision of each patient. All the patients were followed up for over 20 months. Clinical outcomes were assessed and compared using elbow range of motion (ROM), mayo elbow performance score (MEPS) and range of rotation (ROR) during the last follow-up visit. Additionally, pain levels measured by a 10-point visual analog scale (VAS) and complications were duly documented.

Results: In terms of operative time, length of incision, and VAS scores, no significant differences were observed (p > 0.05). The patients were followed up at an average of 33.1 months (range, 22-49 months). The mean MEPS were 89.44 ± 3.79 and 89.58 ± 3.34 (p = 0.89), the mean ROM were 122.28 ± 5.87 and 125.1 ± 5.83 (p = 0.27), and the mean ROR were 153.33 ± 5.94 and 155.83 ± 5.15 (p = 0.26) in groups A and B, respectively. In addition, two children in Metal group experienced symptoms of screw stimulation, while Absorbable group did not.

Conclusion: The use of absorbable screws in treating pediatric medial epicondyle fractures can yield equivalent therapeutic outcomes to traditional metal screws, obviating the need for subsequent surgical interventions and mitigating complications associated with screw irritation resulting from non-degradable metallic implants.

求助全文
约1分钟内获得全文 求助全文
来源期刊
Journal of Orthopaedic Science
Journal of Orthopaedic Science 医学-整形外科
CiteScore
3.00
自引率
0.00%
发文量
290
审稿时长
90 days
期刊介绍: The Journal of Orthopaedic Science is the official peer-reviewed journal of the Japanese Orthopaedic Association. The journal publishes the latest researches and topical debates in all fields of clinical and experimental orthopaedics, including musculoskeletal medicine, sports medicine, locomotive syndrome, trauma, paediatrics, oncology and biomaterials, as well as basic researches.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信