Expression of beam hardening artifacts on horizontally stitched cone-beam computed tomography images.

IF 1.7 Q3 DENTISTRY, ORAL SURGERY & MEDICINE
Imaging Science in Dentistry Pub Date : 2024-12-01 Epub Date: 2024-08-25 DOI:10.5624/isd.20240061
Juliana B Melo da Fonte, Rocharles Cavalcante Fontenele, Deborah Queiroz Freitas
{"title":"Expression of beam hardening artifacts on horizontally stitched cone-beam computed tomography images.","authors":"Juliana B Melo da Fonte, Rocharles Cavalcante Fontenele, Deborah Queiroz Freitas","doi":"10.5624/isd.20240061","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>This study was performed to evaluate the expression of beam hardening artifacts generated by high atomic number materials in stitched cone-beam computed tomography (CBCT) images, compared to the traditional acquisition mode.</p><p><strong>Materials and methods: </strong>CBCT volumes were acquired using an acrylic resin phantom embedded with pairs of cylinders made from amalgam dental alloy, cobalt-chromium alloy, gutta-percha, titanium, and zirconium. These cylinders were placed within the overlapping zones of the stitching reconstruction area. For each material, 3 acquisitions were conducted: 1 utilizing the automatic stitching process with a FOV of 80×37 mm, and 2 with smaller FOVs of 50×37 mm. For the smaller FOVs, 1 scan targeted the anterior region, while the other focused on the left posterior region. Thus, 3 groups were formed: stitched FOV, anterior FOV, and posterior FOV. Artifact expression was assessed by calculating the means and standard deviations (SDs) of the gray values in 4 regions of interest located anteriorly, posteriorly, medially, and laterally to the cylinders. Analysis of variance was used to compare the data, with an alpha level of 5%.</p><p><strong>Results: </strong>The stitched FOV exhibited lower SD values than the posterior and anterior FOVs (<i>P</i><0.05). Regarding the materials evaluated, amalgam, cobalt-chromium, and zirconium generally demonstrated higher SDs of the gray values than gutta-percha and titanium (<i>P</i><0.05).</p><p><strong>Conclusion: </strong>Horizontally stitched CBCT images demonstrated lower artifact expression compared to the traditional mode of acquisition.</p>","PeriodicalId":51714,"journal":{"name":"Imaging Science in Dentistry","volume":"54 4","pages":"327-335"},"PeriodicalIF":1.7000,"publicationDate":"2024-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11685307/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Imaging Science in Dentistry","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5624/isd.20240061","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/8/25 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: This study was performed to evaluate the expression of beam hardening artifacts generated by high atomic number materials in stitched cone-beam computed tomography (CBCT) images, compared to the traditional acquisition mode.

Materials and methods: CBCT volumes were acquired using an acrylic resin phantom embedded with pairs of cylinders made from amalgam dental alloy, cobalt-chromium alloy, gutta-percha, titanium, and zirconium. These cylinders were placed within the overlapping zones of the stitching reconstruction area. For each material, 3 acquisitions were conducted: 1 utilizing the automatic stitching process with a FOV of 80×37 mm, and 2 with smaller FOVs of 50×37 mm. For the smaller FOVs, 1 scan targeted the anterior region, while the other focused on the left posterior region. Thus, 3 groups were formed: stitched FOV, anterior FOV, and posterior FOV. Artifact expression was assessed by calculating the means and standard deviations (SDs) of the gray values in 4 regions of interest located anteriorly, posteriorly, medially, and laterally to the cylinders. Analysis of variance was used to compare the data, with an alpha level of 5%.

Results: The stitched FOV exhibited lower SD values than the posterior and anterior FOVs (P<0.05). Regarding the materials evaluated, amalgam, cobalt-chromium, and zirconium generally demonstrated higher SDs of the gray values than gutta-percha and titanium (P<0.05).

Conclusion: Horizontally stitched CBCT images demonstrated lower artifact expression compared to the traditional mode of acquisition.

水平缝合锥束计算机断层图像上光束硬化伪影的表达。
目的:本研究评估高原子序数材料在缝合锥形束计算机断层扫描(CBCT)图像中与传统采集模式相比产生的束硬化伪影的表达。材料和方法:CBCT体积采用丙烯酸树脂模体,嵌入由汞合金牙科合金、钴铬合金、胶过胶、钛和锆制成的成对圆柱体。这些圆柱体被放置在拼接重建区域的重叠区域内。对于每种材料,进行了3次采集:1次使用视场为80×37 mm的自动拼接过程,2次使用视场较小的50×37 mm。对于较小的fov,一次扫描针对前部区域,另一次扫描针对左侧后部区域。将视场分为缝合视场、前视场、后视场三组。通过计算位于圆柱体前面、后面、中间和侧面的4个感兴趣区域的灰度值的均值和标准差(SDs)来评估伪影表达。方差分析用于比较数据,α水平为5%。结论:水平缝合的CBCT图像与传统的采集方式相比,伪影表达更低。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Imaging Science in Dentistry
Imaging Science in Dentistry DENTISTRY, ORAL SURGERY & MEDICINE-
CiteScore
2.90
自引率
11.10%
发文量
42
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信