Juliana B Melo da Fonte, Rocharles Cavalcante Fontenele, Deborah Queiroz Freitas
{"title":"Expression of beam hardening artifacts on horizontally stitched cone-beam computed tomography images.","authors":"Juliana B Melo da Fonte, Rocharles Cavalcante Fontenele, Deborah Queiroz Freitas","doi":"10.5624/isd.20240061","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>This study was performed to evaluate the expression of beam hardening artifacts generated by high atomic number materials in stitched cone-beam computed tomography (CBCT) images, compared to the traditional acquisition mode.</p><p><strong>Materials and methods: </strong>CBCT volumes were acquired using an acrylic resin phantom embedded with pairs of cylinders made from amalgam dental alloy, cobalt-chromium alloy, gutta-percha, titanium, and zirconium. These cylinders were placed within the overlapping zones of the stitching reconstruction area. For each material, 3 acquisitions were conducted: 1 utilizing the automatic stitching process with a FOV of 80×37 mm, and 2 with smaller FOVs of 50×37 mm. For the smaller FOVs, 1 scan targeted the anterior region, while the other focused on the left posterior region. Thus, 3 groups were formed: stitched FOV, anterior FOV, and posterior FOV. Artifact expression was assessed by calculating the means and standard deviations (SDs) of the gray values in 4 regions of interest located anteriorly, posteriorly, medially, and laterally to the cylinders. Analysis of variance was used to compare the data, with an alpha level of 5%.</p><p><strong>Results: </strong>The stitched FOV exhibited lower SD values than the posterior and anterior FOVs (<i>P</i><0.05). Regarding the materials evaluated, amalgam, cobalt-chromium, and zirconium generally demonstrated higher SDs of the gray values than gutta-percha and titanium (<i>P</i><0.05).</p><p><strong>Conclusion: </strong>Horizontally stitched CBCT images demonstrated lower artifact expression compared to the traditional mode of acquisition.</p>","PeriodicalId":51714,"journal":{"name":"Imaging Science in Dentistry","volume":"54 4","pages":"327-335"},"PeriodicalIF":1.7000,"publicationDate":"2024-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11685307/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Imaging Science in Dentistry","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5624/isd.20240061","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/8/25 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0
Abstract
Purpose: This study was performed to evaluate the expression of beam hardening artifacts generated by high atomic number materials in stitched cone-beam computed tomography (CBCT) images, compared to the traditional acquisition mode.
Materials and methods: CBCT volumes were acquired using an acrylic resin phantom embedded with pairs of cylinders made from amalgam dental alloy, cobalt-chromium alloy, gutta-percha, titanium, and zirconium. These cylinders were placed within the overlapping zones of the stitching reconstruction area. For each material, 3 acquisitions were conducted: 1 utilizing the automatic stitching process with a FOV of 80×37 mm, and 2 with smaller FOVs of 50×37 mm. For the smaller FOVs, 1 scan targeted the anterior region, while the other focused on the left posterior region. Thus, 3 groups were formed: stitched FOV, anterior FOV, and posterior FOV. Artifact expression was assessed by calculating the means and standard deviations (SDs) of the gray values in 4 regions of interest located anteriorly, posteriorly, medially, and laterally to the cylinders. Analysis of variance was used to compare the data, with an alpha level of 5%.
Results: The stitched FOV exhibited lower SD values than the posterior and anterior FOVs (P<0.05). Regarding the materials evaluated, amalgam, cobalt-chromium, and zirconium generally demonstrated higher SDs of the gray values than gutta-percha and titanium (P<0.05).
Conclusion: Horizontally stitched CBCT images demonstrated lower artifact expression compared to the traditional mode of acquisition.