Assessment of implant stability with resonance frequency analysis and changes in the thickness of keratinized tissue and crestal bone level using cone-beam computed tomography in two-stage implants: A three-dimensional clinicoradiographic study.

Q2 Dentistry
Neha Singh, Nichenametla Rajesh, Amirisetty Ramesh
{"title":"Assessment of implant stability with resonance frequency analysis and changes in the thickness of keratinized tissue and crestal bone level using cone-beam computed tomography in two-stage implants: A three-dimensional clinicoradiographic study.","authors":"Neha Singh, Nichenametla Rajesh, Amirisetty Ramesh","doi":"10.4103/jisp.jisp_122_23","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>The present study aims to evaluate a three-dimensional (3D) changes in the crestal bone levels (buccally, lingually/palatally, mesially, and distally) and in the thickness of keratinized tissue around single or multiple implants using cone-beam computed tomography (CBCT) after 1 year.</p><p><strong>Materials and methods: </strong>Twenty-eight implants were placed in the posterior load-bearing areas in 10 patients. The crestal bone levels and the thickness of keratinized tissue surrounding the edentulous area were assessed preoperatively, immediately after implant placement, and 1 year after implant placement using CBCT (3D imaging technique with DICOM software (Carestream Health, Rochester, NY)). Implant stability quotient (ISQ) was measured immediately after implant placement using resonance frequency analysis (RFA) (Penguin RFA Monitor Osseointegration, Integration Diagnostics Sweden AB, Furstenbergsgatan 4 416 64 Göteborg, Sweden).</p><p><strong>Results: </strong>The average crestal bone loss around the implants after 1 year was 0.78 ± 0.26 mm on the buccal side, 0.63 ± 0.27 mm on the lingual side, 0.57 ± 0.18 mm on the mesial side, and 0.53 ± 0.28 mm on the distal side. The average amount of bone loss including all sites was 0.63 ± 0.17 mm and the mean change in keratinized tissue thickness after 1 year was 0.3 ± 0.19 mm. The RFA ranged from 75 to 82 Nm for all the implants immediately after placement.</p><p><strong>Conclusion: </strong>CBCT can be used as a reliable source, as it is compararively more superior and precise than intraoral periapical radiographs in measuring the changes in the bone and thickness of the keratinized tissue before and after implant placement. A thick biotype of the keratinized tissue is as important as the bone topography for the success of the implant. ISQ measurements immediately after implant placement can also act as a major factor in depicting the success of the implant in the future.</p>","PeriodicalId":15890,"journal":{"name":"Journal of Indian Society of Periodontology","volume":"28 3","pages":"368-375"},"PeriodicalIF":0.0000,"publicationDate":"2024-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11684576/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Indian Society of Periodontology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4103/jisp.jisp_122_23","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/12/2 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"Dentistry","Score":null,"Total":0}
引用次数: 0

Abstract

Background: The present study aims to evaluate a three-dimensional (3D) changes in the crestal bone levels (buccally, lingually/palatally, mesially, and distally) and in the thickness of keratinized tissue around single or multiple implants using cone-beam computed tomography (CBCT) after 1 year.

Materials and methods: Twenty-eight implants were placed in the posterior load-bearing areas in 10 patients. The crestal bone levels and the thickness of keratinized tissue surrounding the edentulous area were assessed preoperatively, immediately after implant placement, and 1 year after implant placement using CBCT (3D imaging technique with DICOM software (Carestream Health, Rochester, NY)). Implant stability quotient (ISQ) was measured immediately after implant placement using resonance frequency analysis (RFA) (Penguin RFA Monitor Osseointegration, Integration Diagnostics Sweden AB, Furstenbergsgatan 4 416 64 Göteborg, Sweden).

Results: The average crestal bone loss around the implants after 1 year was 0.78 ± 0.26 mm on the buccal side, 0.63 ± 0.27 mm on the lingual side, 0.57 ± 0.18 mm on the mesial side, and 0.53 ± 0.28 mm on the distal side. The average amount of bone loss including all sites was 0.63 ± 0.17 mm and the mean change in keratinized tissue thickness after 1 year was 0.3 ± 0.19 mm. The RFA ranged from 75 to 82 Nm for all the implants immediately after placement.

Conclusion: CBCT can be used as a reliable source, as it is compararively more superior and precise than intraoral periapical radiographs in measuring the changes in the bone and thickness of the keratinized tissue before and after implant placement. A thick biotype of the keratinized tissue is as important as the bone topography for the success of the implant. ISQ measurements immediately after implant placement can also act as a major factor in depicting the success of the implant in the future.

利用锥形束计算机断层扫描评估两段种植体中角化组织厚度和嵴骨水平变化的共振频率分析和种植体稳定性:一项三维临床放射学研究。
背景:本研究旨在利用锥形束计算机断层扫描(CBCT)评估1年后冠骨水平(颊部、舌部/腭部、中端和远端)和单个或多个种植体周围角化组织厚度的三维变化。材料与方法:在10例患者后侧负重区放置28颗种植体。采用CBCT(采用DICOM软件的3D成像技术(Carestream Health, Rochester, NY))在术前、种植体放置后立即和种植体放置后1年评估无牙区周围的嵴骨水平和角化组织厚度。种植体放置后立即使用共振频率分析(RFA)测量种植体稳定商(ISQ) (Penguin RFA Monitor Osseointegration, Integration Diagnostics Sweden AB, Furstenbergsgatan 4 416 64 Göteborg,瑞典)。结果:种植体周围牙冠骨缺损1年后平均颊侧0.78±0.26 mm,舌侧0.63±0.27 mm,中侧0.57±0.18 mm,远侧0.53±0.28 mm。各部位骨丢失量平均为0.63±0.17 mm, 1年后角质化组织厚度平均变化0.3±0.19 mm。所有植入物放置后即刻的RFA范围为75 ~ 82 Nm。结论:CBCT在测量种植体植入前后角化组织的骨和厚度变化方面相对于口内根尖周x线片更为优越和精确,可作为一种可靠的来源。角化组织的厚生物型与骨地形对种植体的成功同样重要。在植入后立即测量ISQ也可以作为描述未来植入成功的主要因素。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
1.70
自引率
0.00%
发文量
87
审稿时长
44 weeks
期刊介绍: The Journal of Indian Society of Periodontology publishes original scientific articles to support practice , education and research in the dental specialty of periodontology and oral implantology. Journal of Indian Society of Periodontology (JISP), is the official publication of the Society and is managed and brought out by the Editor of the society. The journal is published Bimonthly with special issues being brought out for specific occasions. The ISP had a bulletin as its publication for a large number of years and was enhanced as a Journal a few years ago
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信