Antimicrobial Responses to Bacterial Metabolic Activity and Biofilm Formation Studied Using Microbial Fuel Cell-Based Biosensors.

IF 4.9 3区 工程技术 Q1 CHEMISTRY, ANALYTICAL
Wenguo Wu, Huiya Hong, Jia Lin, Dayun Yang
{"title":"Antimicrobial Responses to Bacterial Metabolic Activity and Biofilm Formation Studied Using Microbial Fuel Cell-Based Biosensors.","authors":"Wenguo Wu, Huiya Hong, Jia Lin, Dayun Yang","doi":"10.3390/bios14120606","DOIUrl":null,"url":null,"abstract":"<p><p>Simultaneous monitoring of antimicrobial responses to bacterial metabolic activity and biofilm formation is critical for efficient screening of new anti-biofilm drugs. A microbial fuel cell-based biosensor using <i>Pseudomonas aeruginosa</i> as an electricigen was constructed. The effects of silver nanoparticles (AgNPs) on the cellular metabolic activity and biofilm formation of <i>P. aeruginosa</i> in the biosensors were investigated and compared with the traditional biofilm detection method. The crystal violet staining results showed that the concentration of AgNPs being increased to 20 and 40 μg/mL had a slight and obvious inhibitory effect on biofilm formation, respectively. In comparison, the detection sensitivity of the biosensor was much higher. When the concentration of AgNPs was 5 μg/mL, the output voltage of the biosensor was suppressed, and the inhibition gradually increased with the AgNPs dose. AgNPs inhibited the activity of planktonic cells in the anolyte and the formation of biofilm on the anode surface, and it had a dose-dependent effect on the secretion of phenazine in the anolyte. The biosensor could monitor the impacts of AgNPs not only on biofilm formation but also on cell activity and metabolic activity. It provides a new and sensitive method for the screening of anti-biofilm drugs.</p>","PeriodicalId":48608,"journal":{"name":"Biosensors-Basel","volume":"14 12","pages":""},"PeriodicalIF":4.9000,"publicationDate":"2024-12-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11674809/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Biosensors-Basel","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.3390/bios14120606","RegionNum":3,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0

Abstract

Simultaneous monitoring of antimicrobial responses to bacterial metabolic activity and biofilm formation is critical for efficient screening of new anti-biofilm drugs. A microbial fuel cell-based biosensor using Pseudomonas aeruginosa as an electricigen was constructed. The effects of silver nanoparticles (AgNPs) on the cellular metabolic activity and biofilm formation of P. aeruginosa in the biosensors were investigated and compared with the traditional biofilm detection method. The crystal violet staining results showed that the concentration of AgNPs being increased to 20 and 40 μg/mL had a slight and obvious inhibitory effect on biofilm formation, respectively. In comparison, the detection sensitivity of the biosensor was much higher. When the concentration of AgNPs was 5 μg/mL, the output voltage of the biosensor was suppressed, and the inhibition gradually increased with the AgNPs dose. AgNPs inhibited the activity of planktonic cells in the anolyte and the formation of biofilm on the anode surface, and it had a dose-dependent effect on the secretion of phenazine in the anolyte. The biosensor could monitor the impacts of AgNPs not only on biofilm formation but also on cell activity and metabolic activity. It provides a new and sensitive method for the screening of anti-biofilm drugs.

利用基于微生物燃料电池的生物传感器研究细菌代谢活性和生物膜形成的抗菌反应。
同时监测抗菌药物对细菌代谢活性和生物膜形成的反应对于有效筛选新的抗生物膜药物至关重要。构建了一种以铜绿假单胞菌为电源的微生物燃料电池传感器。研究了银纳米颗粒(AgNPs)对铜绿假单胞菌(P. aeruginosa)在生物传感器中的细胞代谢活性和生物膜形成的影响,并与传统的生物膜检测方法进行了比较。结晶紫染色结果显示,AgNPs浓度分别增加到20和40 μg/mL时,对生物膜的形成有轻微和明显的抑制作用。相比之下,生物传感器的检测灵敏度要高得多。当AgNPs浓度为5 μg/mL时,生物传感器的输出电压受到抑制,随着AgNPs剂量的增加,抑制作用逐渐增强。AgNPs抑制阳极液中浮游细胞的活性和阳极表面生物膜的形成,并对阳极液中苯那嗪的分泌有剂量依赖性。该传感器不仅可以监测AgNPs对生物膜形成的影响,还可以监测AgNPs对细胞活性和代谢活性的影响。为抗生物膜药物的筛选提供了一种灵敏的新方法。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Biosensors-Basel
Biosensors-Basel Biochemistry, Genetics and Molecular Biology-Clinical Biochemistry
CiteScore
6.60
自引率
14.80%
发文量
983
审稿时长
11 weeks
期刊介绍: Biosensors (ISSN 2079-6374) provides an advanced forum for studies related to the science and technology of biosensors and biosensing. It publishes original research papers, comprehensive reviews and communications. Our aim is to encourage scientists to publish their experimental and theoretical results in as much detail as possible. There is no restriction on the length of the papers. The full experimental details must be provided so that the results can be reproduced. Electronic files and software regarding the full details of the calculation or experimental procedure, if unable to be published in a normal way, can be deposited as supplementary electronic material.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信