Magdalena Ferrere, Ignacio Garcia-Mansilla, Agustina de Gainza
{"title":"Navigating postoperative complications: Uveitis-glaucoma-hyphema syndrome after Ahmed glaucoma valve implantation.","authors":"Magdalena Ferrere, Ignacio Garcia-Mansilla, Agustina de Gainza","doi":"10.12998/wjcc.v12.i36.6944","DOIUrl":null,"url":null,"abstract":"<p><p>Altwijri and Alsirhy reported a case of uveitis-glaucoma-hyphema syndrome after an Ahmed glaucoma valve implantation surgery in an advanced primary open-angle glaucoma patient, being the first ever recorded of its kind. The author describes the position of the tube as the origin of the anterior chamber inflammation and hyphema, which resolved shortly after shortening and relocating it. This publication emphasizes the importance of precise implant positioning and close-up patient follow-up after glaucoma filtration surgery as an important standard for healthcare providers.</p>","PeriodicalId":23912,"journal":{"name":"World Journal of Clinical Cases","volume":"12 36","pages":"6944-6946"},"PeriodicalIF":1.0000,"publicationDate":"2024-12-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11531985/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"World Journal of Clinical Cases","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.12998/wjcc.v12.i36.6944","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"MEDICINE, GENERAL & INTERNAL","Score":null,"Total":0}
引用次数: 0
Abstract
Altwijri and Alsirhy reported a case of uveitis-glaucoma-hyphema syndrome after an Ahmed glaucoma valve implantation surgery in an advanced primary open-angle glaucoma patient, being the first ever recorded of its kind. The author describes the position of the tube as the origin of the anterior chamber inflammation and hyphema, which resolved shortly after shortening and relocating it. This publication emphasizes the importance of precise implant positioning and close-up patient follow-up after glaucoma filtration surgery as an important standard for healthcare providers.
期刊介绍:
The World Journal of Clinical Cases (WJCC) is a high-quality, peer reviewed, open-access journal. The primary task of WJCC is to rapidly publish high-quality original articles, reviews, editorials, and case reports in the field of clinical cases. In order to promote productive academic communication, the peer review process for the WJCC is transparent; to this end, all published manuscripts are accompanied by the anonymized reviewers’ comments as well as the authors’ responses. The primary aims of the WJCC are to improve diagnostic, therapeutic and preventive modalities and the skills of clinicians and to guide clinical practice in clinical cases.