Influence of vascular embolism level and drug injection rate on thrombolytic therapy of bifurcated femoral vein: Numerical simulation and validation study.

IF 4.9 2区 医学 Q1 COMPUTER SCIENCE, INTERDISCIPLINARY APPLICATIONS
Xianglei Zhang, Hongyu Cheng, Boyuan Lin, Sisi Li, Hongming Zhou, Mingrui Huang, Jiahao Wu
{"title":"Influence of vascular embolism level and drug injection rate on thrombolytic therapy of bifurcated femoral vein: Numerical simulation and validation study.","authors":"Xianglei Zhang, Hongyu Cheng, Boyuan Lin, Sisi Li, Hongming Zhou, Mingrui Huang, Jiahao Wu","doi":"10.1016/j.cmpb.2024.108570","DOIUrl":null,"url":null,"abstract":"<p><strong>Background and objective: </strong>Deep vein thrombosis (DVT) of the lower limbs is a critical global vascular disease. Accurately assessing and predicting the efficacy of DVT treatment remains a significant challenge due to a lack of understanding of the mechanisms by which the level of patient-specific embolization and the rate of drug injection affect thrombolytic therapy.</p><p><strong>Methods: </strong>In this study, we used the computed tomographic venography (CTV) clinical method to obtain patient-specific parameters, and the flow-solid interaction (FSI) method combined with biochemical response modeling of thrombolysis to analyze patient-specific hemodynamic and biomechanical characteristics and to quantitatively assess the effects of three vessel embolism levels (VEL) versus two drug injection rates (DIR) on bifurcated femoral venous thrombolytic therapy. In addition, we verified the reliability of the simulation results by in vitro thrombolytic therapy experiments.</p><p><strong>Results: </strong>In the bifurcated femoral vein, the state of blood flow, vortex, wall shear stress (WSS), time-averaged wall shear stress (TAWSS), vessel wall pressure, leaflet motion displacement, and valve von Mises stress vary with thrombus size and vessel shape. Venous valves accelerate blood flow, producing a jet phenomenon. From the numerical and experimental results, thrombolytic therapy should select the injection rate according to the severity of the thrombus. Rapid injection restores flow in mild thrombosis, while slow injection ensures gradual drug penetration for serious thrombosis.</p><p><strong>Conclusions: </strong>The present study found that the hemodynamic parameters and biomechanical characteristics explored are closely related to the efficacy of thrombolytic therapy. Both hemodynamic parameters and biomechanical characteristics are affected by blood flow velocity. At the same time, the study also revealed the mechanism of the influence of VTE and DIR on bifurcated venous thrombolytic therapy, to provide a scientific basis for clinicians to formulate more precise treatment strategies.</p>","PeriodicalId":10624,"journal":{"name":"Computer methods and programs in biomedicine","volume":"260 ","pages":"108570"},"PeriodicalIF":4.9000,"publicationDate":"2024-12-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Computer methods and programs in biomedicine","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1016/j.cmpb.2024.108570","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"COMPUTER SCIENCE, INTERDISCIPLINARY APPLICATIONS","Score":null,"Total":0}
引用次数: 0

Abstract

Background and objective: Deep vein thrombosis (DVT) of the lower limbs is a critical global vascular disease. Accurately assessing and predicting the efficacy of DVT treatment remains a significant challenge due to a lack of understanding of the mechanisms by which the level of patient-specific embolization and the rate of drug injection affect thrombolytic therapy.

Methods: In this study, we used the computed tomographic venography (CTV) clinical method to obtain patient-specific parameters, and the flow-solid interaction (FSI) method combined with biochemical response modeling of thrombolysis to analyze patient-specific hemodynamic and biomechanical characteristics and to quantitatively assess the effects of three vessel embolism levels (VEL) versus two drug injection rates (DIR) on bifurcated femoral venous thrombolytic therapy. In addition, we verified the reliability of the simulation results by in vitro thrombolytic therapy experiments.

Results: In the bifurcated femoral vein, the state of blood flow, vortex, wall shear stress (WSS), time-averaged wall shear stress (TAWSS), vessel wall pressure, leaflet motion displacement, and valve von Mises stress vary with thrombus size and vessel shape. Venous valves accelerate blood flow, producing a jet phenomenon. From the numerical and experimental results, thrombolytic therapy should select the injection rate according to the severity of the thrombus. Rapid injection restores flow in mild thrombosis, while slow injection ensures gradual drug penetration for serious thrombosis.

Conclusions: The present study found that the hemodynamic parameters and biomechanical characteristics explored are closely related to the efficacy of thrombolytic therapy. Both hemodynamic parameters and biomechanical characteristics are affected by blood flow velocity. At the same time, the study also revealed the mechanism of the influence of VTE and DIR on bifurcated venous thrombolytic therapy, to provide a scientific basis for clinicians to formulate more precise treatment strategies.

求助全文
约1分钟内获得全文 求助全文
来源期刊
Computer methods and programs in biomedicine
Computer methods and programs in biomedicine 工程技术-工程:生物医学
CiteScore
12.30
自引率
6.60%
发文量
601
审稿时长
135 days
期刊介绍: To encourage the development of formal computing methods, and their application in biomedical research and medical practice, by illustration of fundamental principles in biomedical informatics research; to stimulate basic research into application software design; to report the state of research of biomedical information processing projects; to report new computer methodologies applied in biomedical areas; the eventual distribution of demonstrable software to avoid duplication of effort; to provide a forum for discussion and improvement of existing software; to optimize contact between national organizations and regional user groups by promoting an international exchange of information on formal methods, standards and software in biomedicine. Computer Methods and Programs in Biomedicine covers computing methodology and software systems derived from computing science for implementation in all aspects of biomedical research and medical practice. It is designed to serve: biochemists; biologists; geneticists; immunologists; neuroscientists; pharmacologists; toxicologists; clinicians; epidemiologists; psychiatrists; psychologists; cardiologists; chemists; (radio)physicists; computer scientists; programmers and systems analysts; biomedical, clinical, electrical and other engineers; teachers of medical informatics and users of educational software.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信