Alexander von Vopelius-Feldt, Timothy Hamann, Andreas Mayr, Marc Töteberg-Harms
{"title":"Evaluation of Reproducibility of Measurements of Peripapillary Blood Flow with Laser Speckle Flowgraphy in Healthy and POAG Subjects.","authors":"Alexander von Vopelius-Feldt, Timothy Hamann, Andreas Mayr, Marc Töteberg-Harms","doi":"10.1055/a-2469-8403","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Peripapillary blood flow is of diagnostic value in glaucoma.</p><p><strong>Material and methods: </strong>We investigated the reproducibility of peripapillary blood flow measurements in healthy individuals and in open-angle glaucoma (OAG) patients with the Nidek laser speckle flowgraphy (LSFG)-NAVI system. Blood flow was calculated as the mean of vascular area (MV), mean of tissue area (MT), and mean of overall flow (MA). Intra-rater, inter-session, and inter-rater reproducibility were assessed by determining the intraclass correlation coefficient (ICC) and coefficient of variance (COV).</p><p><strong>Results: </strong>There were 28 healthy subjects and 16 patients with OAG who participated in this prospective single-center trial. ICC and COV of intra-rater reproducibility were assessed in MV as 0.901; 6.424, MT as 0.909; 4.025, and MA as 0.965; 4.168. Inter-session reproducibility yielded ICC and COV values of MV (0.834; 9.223), MT (0.904; 6.215), MA (0.909; 7.069). Inter-rater reproducibility was computed for MV as 0.78; 9.758, MT as 0.890; 7.210, and MA as 0.888; 6.942. There was a significant difference in MA (p = 0.0184) between the healthy individuals (mean 36.299) and the OAG group (mean 24.944), which was not observed for MV (p = 0.0735) or MT (<i>p = </i>0.1351).</p><p><strong>Conclusion: </strong>High reproducibility of measurements of peripapillary blood flow with the LSFG system was demonstrated in both groups. There is a difference in peripapillary blood flow between healthy controls and OAG patients.</p>","PeriodicalId":17904,"journal":{"name":"Klinische Monatsblatter fur Augenheilkunde","volume":" ","pages":""},"PeriodicalIF":0.8000,"publicationDate":"2024-12-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Klinische Monatsblatter fur Augenheilkunde","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1055/a-2469-8403","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0
Abstract
Background: Peripapillary blood flow is of diagnostic value in glaucoma.
Material and methods: We investigated the reproducibility of peripapillary blood flow measurements in healthy individuals and in open-angle glaucoma (OAG) patients with the Nidek laser speckle flowgraphy (LSFG)-NAVI system. Blood flow was calculated as the mean of vascular area (MV), mean of tissue area (MT), and mean of overall flow (MA). Intra-rater, inter-session, and inter-rater reproducibility were assessed by determining the intraclass correlation coefficient (ICC) and coefficient of variance (COV).
Results: There were 28 healthy subjects and 16 patients with OAG who participated in this prospective single-center trial. ICC and COV of intra-rater reproducibility were assessed in MV as 0.901; 6.424, MT as 0.909; 4.025, and MA as 0.965; 4.168. Inter-session reproducibility yielded ICC and COV values of MV (0.834; 9.223), MT (0.904; 6.215), MA (0.909; 7.069). Inter-rater reproducibility was computed for MV as 0.78; 9.758, MT as 0.890; 7.210, and MA as 0.888; 6.942. There was a significant difference in MA (p = 0.0184) between the healthy individuals (mean 36.299) and the OAG group (mean 24.944), which was not observed for MV (p = 0.0735) or MT (p = 0.1351).
Conclusion: High reproducibility of measurements of peripapillary blood flow with the LSFG system was demonstrated in both groups. There is a difference in peripapillary blood flow between healthy controls and OAG patients.
期刊介绍:
-Konzentriertes Fachwissen aus Klinik und Praxis:
Die entscheidenden Ergebnisse der internationalen Forschung - für Sie auf den Punkt gebracht und kritisch kommentiert,
Übersichtsarbeiten zu den maßgeblichen Themen der täglichen Praxis,
Top informiert - breite klinische Berichterstattung.
-CME-Punkte sammeln mit dem Refresher:
Effiziente, CME-zertifizierte Fortbildung, mit dem Refresher,
3 CME-Punkte pro Ausgabe - bis zu 36 CME-Punkte im Jahr!.
-Aktuelle Rubriken mit echtem Nutzwert:
Kurzreferate zu den wichtigsten Artikeln internationaler Zeitschriften,
Schwerpunktthema in jedem Heft: Ausführliche Übersichtsarbeiten zu den wichtigsten Themen der Ophthalmologie – so behalten Sie das gesamte Fach im Blick!,
Originalien mit den neuesten Entwicklungen,
Übersichten zu den relevanten Themen.