Synchronized Contrast-Enhanced 4DCT Simulation for Target Volume Delineation in Abdominal SBRT.

IF 4.5 2区 医学 Q1 ONCOLOGY
Cancers Pub Date : 2024-12-04 DOI:10.3390/cancers16234066
Valeria Faccenda, Denis Panizza, Rita Marina Niespolo, Riccardo Ray Colciago, Giulia Rossano, Lorenzo De Sanctis, Davide Gandola, Davide Ippolito, Stefano Arcangeli, Elena De Ponti
{"title":"Synchronized Contrast-Enhanced 4DCT Simulation for Target Volume Delineation in Abdominal SBRT.","authors":"Valeria Faccenda, Denis Panizza, Rita Marina Niespolo, Riccardo Ray Colciago, Giulia Rossano, Lorenzo De Sanctis, Davide Gandola, Davide Ippolito, Stefano Arcangeli, Elena De Ponti","doi":"10.3390/cancers16234066","DOIUrl":null,"url":null,"abstract":"<p><p><b>Background/Objectives:</b> To present the technical aspects of contrast-enhanced 4DCT (ce4DCT) simulation for abdominal SBRT. <b>Methods:</b> Twenty-two patients underwent two sequential 4DCT scans: one baseline and one contrast-enhanced with personalized delay time (<i>t<sub>delay</sub></i>) calculated to capture the tumor in the desired contrast phase, based on diagnostic triple-phase CT. The internal target volume (ITV) was delineated on ten contrast phases, and a panel of three experts qualitatively evaluated tumor visibility. Aortic HU values were measured to refine the <i>t<sub>delay</sub></i> for subsequent patients. The commonly used approach of combining triple-phase CT with unenhanced 4DCT was simulated, and differences in target delineation were evaluated by volume, centroid shift, Dice and Jaccard indices, and mean distance agreement (MDA). The margins required to account for motion were calculated. <b>Results:</b> The ce4DCT acquisitions substantially improved tumor visibility over the entire breathing cycle in 20 patients, according to the experts' unanimous evaluation. The median contrast peak time was 54.5 s, and the washout plateau was observed at 70.3 s, with mean peak and plateau HU values of 292 ± 59 and 169 ± 25. The volumes from the commonly used procedure (ITV2) were significantly smaller than the ce4DCT volumes (ITV1) (<i>p</i> = 0.045). The median centroid shift was 4.7 mm. The ITV1-ITV2 overlap was 69% (Dice index), 53% (Jaccard index), and 2.89 mm (MDA), with the liver volumes showing significantly lower indices compared to the pancreatic volumes (<i>p</i> ≤ 0.011). The margins required to better encompass ITV1 were highly variable, with mean values ≥ 4 mm in all directions except for the left-right axis. <b>Conclusions:</b> The ce4DCT simulation was feasible, resulting in optimal tumor enhancement with minimal resource investment, while significantly mitigating uncertainties in SBRT planning by addressing poor visibility and respiratory motion. Triple-phase 3DCT with unenhanced 4DCT led to high variability in target delineation, making the isotropic margins ineffective.</p>","PeriodicalId":9681,"journal":{"name":"Cancers","volume":"16 23","pages":""},"PeriodicalIF":4.5000,"publicationDate":"2024-12-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Cancers","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.3390/cancers16234066","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ONCOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Background/Objectives: To present the technical aspects of contrast-enhanced 4DCT (ce4DCT) simulation for abdominal SBRT. Methods: Twenty-two patients underwent two sequential 4DCT scans: one baseline and one contrast-enhanced with personalized delay time (tdelay) calculated to capture the tumor in the desired contrast phase, based on diagnostic triple-phase CT. The internal target volume (ITV) was delineated on ten contrast phases, and a panel of three experts qualitatively evaluated tumor visibility. Aortic HU values were measured to refine the tdelay for subsequent patients. The commonly used approach of combining triple-phase CT with unenhanced 4DCT was simulated, and differences in target delineation were evaluated by volume, centroid shift, Dice and Jaccard indices, and mean distance agreement (MDA). The margins required to account for motion were calculated. Results: The ce4DCT acquisitions substantially improved tumor visibility over the entire breathing cycle in 20 patients, according to the experts' unanimous evaluation. The median contrast peak time was 54.5 s, and the washout plateau was observed at 70.3 s, with mean peak and plateau HU values of 292 ± 59 and 169 ± 25. The volumes from the commonly used procedure (ITV2) were significantly smaller than the ce4DCT volumes (ITV1) (p = 0.045). The median centroid shift was 4.7 mm. The ITV1-ITV2 overlap was 69% (Dice index), 53% (Jaccard index), and 2.89 mm (MDA), with the liver volumes showing significantly lower indices compared to the pancreatic volumes (p ≤ 0.011). The margins required to better encompass ITV1 were highly variable, with mean values ≥ 4 mm in all directions except for the left-right axis. Conclusions: The ce4DCT simulation was feasible, resulting in optimal tumor enhancement with minimal resource investment, while significantly mitigating uncertainties in SBRT planning by addressing poor visibility and respiratory motion. Triple-phase 3DCT with unenhanced 4DCT led to high variability in target delineation, making the isotropic margins ineffective.

用于腹部 SBRT 靶区划分的同步对比度增强 4DCT 模拟。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Cancers
Cancers Medicine-Oncology
CiteScore
8.00
自引率
9.60%
发文量
5371
审稿时长
18.07 days
期刊介绍: Cancers (ISSN 2072-6694) is an international, peer-reviewed open access journal on oncology. It publishes reviews, regular research papers and short communications. Our aim is to encourage scientists to publish their experimental and theoretical results in as much detail as possible. There is no restriction on the length of the papers. The full experimental details must be provided so that the results can be reproduced.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信