A comparative in vitro study of different composite materials in terms of aligner attachment accuracy and surface roughness using different curing irradiances.

IF 1.8 Q2 DENTISTRY, ORAL SURGERY & MEDICINE
Servet Erbas, Ezgi Atik
{"title":"A comparative in vitro study of different composite materials in terms of aligner attachment accuracy and surface roughness using different curing irradiances.","authors":"Servet Erbas, Ezgi Atik","doi":"10.1016/j.ortho.2024.100961","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>To evaluate 4 different composite resins in terms of aligner attachment accuracy and surface roughness.</p><p><strong>Material and methods: </strong>160 premolars were divided into 4 groups (n=40): Group 1: GC Aligner Connect™; 2: GC Ortho Connect™; 3: 3M ESPE Filtek™ Z350 XT flowable; 4: 3M ESPE Filtek™ Z350 XT Universal. Each group was divided into 2 equal subgroups regarding curing irradiances (Power of 1000 mW/cm<sup>2</sup> in subgroup A for 10s, and 3200 mW/cm<sup>2</sup>in B for 3s, VALO™ Cordless-LED Curing Light). The primary objective was to compare the realized attachments with those of the virtual with 3D Geomagic software. A contact surface profiler was used for roughness measurement (Ra) as the secondary aim. The data were analysed using the IBM SPSS 25.0. The significance level was set at p<0.05.</p><p><strong>Results: </strong>In subgroup A, the mean \"excess\" accuracy measurement of the 3M ESPE Filtek ™Z350 XT flowable resin was found to be higher than others. In subgroup B, the \"excess\" accuracy measurements of the 3M ESPE Filtek™Z350 XT flowable (0.24±0.07mm) and Universal (0.26±0.05mm) resins were significantly higher than those of the GC Aligner Connect™ resin (0.17±0.06mm), (p<0.05). According to the Ra measurements in subgroup A, the measurement of the GC Aligner Connect™ (1.75±1.09μm), GC Ortho Connect™ (0.99±1.04μm) and 3M ESPE Filtek™ Z350 XT flowable (1.33±1.16μm) resins were found to be higher than of the Universal resin (0.07±0.11μm), (p<0.05). In subgroup B, the Ra measurement of the GC Aligner Connect™ (1.74±1.81μm) was found to be higher than that of the 3M ESPE Filtek™ Z350 XT flowable (0.11±0.18μm) resin (p=0.010). Ra measurement observed for the 10-second curing factor for the 3M ESPE Filtek™ Z350 XT Flowable resin group was found to be significantly higher than for the 3-second curing factor (p<0.001).</p><p><strong>Conclusion: </strong>In terms of \"excess\" value of accuracy, 3M ESPE Filtek™ Z350 XT flowable composite resin showed a higher value. The lowest surface roughness was observed for Universal restorative resin considering low power irradiation, while was observed for 3M ESPE Filtek™ Z350 XT flowable resin considering high power irradiation.</p>","PeriodicalId":45449,"journal":{"name":"International Orthodontics","volume":"23 2","pages":"100961"},"PeriodicalIF":1.8000,"publicationDate":"2024-12-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Orthodontics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1016/j.ortho.2024.100961","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

Abstract

Background: To evaluate 4 different composite resins in terms of aligner attachment accuracy and surface roughness.

Material and methods: 160 premolars were divided into 4 groups (n=40): Group 1: GC Aligner Connect™; 2: GC Ortho Connect™; 3: 3M ESPE Filtek™ Z350 XT flowable; 4: 3M ESPE Filtek™ Z350 XT Universal. Each group was divided into 2 equal subgroups regarding curing irradiances (Power of 1000 mW/cm2 in subgroup A for 10s, and 3200 mW/cm2in B for 3s, VALO™ Cordless-LED Curing Light). The primary objective was to compare the realized attachments with those of the virtual with 3D Geomagic software. A contact surface profiler was used for roughness measurement (Ra) as the secondary aim. The data were analysed using the IBM SPSS 25.0. The significance level was set at p<0.05.

Results: In subgroup A, the mean "excess" accuracy measurement of the 3M ESPE Filtek ™Z350 XT flowable resin was found to be higher than others. In subgroup B, the "excess" accuracy measurements of the 3M ESPE Filtek™Z350 XT flowable (0.24±0.07mm) and Universal (0.26±0.05mm) resins were significantly higher than those of the GC Aligner Connect™ resin (0.17±0.06mm), (p<0.05). According to the Ra measurements in subgroup A, the measurement of the GC Aligner Connect™ (1.75±1.09μm), GC Ortho Connect™ (0.99±1.04μm) and 3M ESPE Filtek™ Z350 XT flowable (1.33±1.16μm) resins were found to be higher than of the Universal resin (0.07±0.11μm), (p<0.05). In subgroup B, the Ra measurement of the GC Aligner Connect™ (1.74±1.81μm) was found to be higher than that of the 3M ESPE Filtek™ Z350 XT flowable (0.11±0.18μm) resin (p=0.010). Ra measurement observed for the 10-second curing factor for the 3M ESPE Filtek™ Z350 XT Flowable resin group was found to be significantly higher than for the 3-second curing factor (p<0.001).

Conclusion: In terms of "excess" value of accuracy, 3M ESPE Filtek™ Z350 XT flowable composite resin showed a higher value. The lowest surface roughness was observed for Universal restorative resin considering low power irradiation, while was observed for 3M ESPE Filtek™ Z350 XT flowable resin considering high power irradiation.

求助全文
约1分钟内获得全文 求助全文
来源期刊
International Orthodontics
International Orthodontics DENTISTRY, ORAL SURGERY & MEDICINE-
CiteScore
2.50
自引率
13.30%
发文量
71
审稿时长
26 days
期刊介绍: Une revue de référence dans le domaine de orthodontie et des disciplines frontières Your reference in dentofacial orthopedics International Orthodontics adresse aux orthodontistes, aux dentistes, aux stomatologistes, aux chirurgiens maxillo-faciaux et aux plasticiens de la face, ainsi quà leurs assistant(e)s. International Orthodontics is addressed to orthodontists, dentists, stomatologists, maxillofacial surgeons and facial plastic surgeons, as well as their assistants.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信