FeCl3 and GdCl3 solutions as superfast relaxation modifiers for agarose gel: a quantitative analysis.

IF 2 4区 医学 Q3 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
Nur Najihah Hamzaini, Syafia Afifi Ghazali, Ahmad Nazlim Yusoff, Faizah Mohd Zaki, Wan Noor Afzan Wan Sulaiman, Yanurita Dwihapsari
{"title":"FeCl<sub>3</sub> and GdCl<sub>3</sub> solutions as superfast relaxation modifiers for agarose gel: a quantitative analysis.","authors":"Nur Najihah Hamzaini, Syafia Afifi Ghazali, Ahmad Nazlim Yusoff, Faizah Mohd Zaki, Wan Noor Afzan Wan Sulaiman, Yanurita Dwihapsari","doi":"10.1007/s10334-024-01216-0","DOIUrl":null,"url":null,"abstract":"<p><strong>Object: </strong>This study aimed to evaluate the relaxivity and uniformity of agarose gel phantoms added with relaxation modifiers. It is hypothesized that the modifiers could manipulate the T1 and T2 relaxations as well as the signal uniformity.</p><p><strong>Materials and methods: </strong>Twenty agarose gel phantoms with different GdCl₃ and FeCl₃ volume fractions were prepared. The phantoms were scanned using a 3-T scanner implementing a turbo spin echo sequence to acquire T1 and T2 images. The SNR of the images were computed using Image-J software from 1, 3, and 25 regions-of-interest (ROIs) and were inverted as T1 and T2 curves.</p><p><strong>Results: </strong>With the increase in relaxation modifier content, T1 SNR increased at a faster rate at very short TR and reached saturation at TR well below 400 ms. Agarose gel phantoms containing GdCl<sub>3</sub> showed a higher saturation value as compared to phantoms containing FeCl<sub>3</sub>. For T2 SNR, differences between plots are observed at low TE. As TE gets larger, the SNR between plots is incomparable. The SNR for both groups was uniform among 1, 3, and 25 ROIs.</p><p><strong>Discussions: </strong>It can be concluded that GdCl₃ and FeCl₃ solutions can be used as effective relaxation modifiers to reduce T1 but not T2 relaxation times.</p>","PeriodicalId":18067,"journal":{"name":"Magnetic Resonance Materials in Physics, Biology and Medicine","volume":" ","pages":""},"PeriodicalIF":2.0000,"publicationDate":"2024-12-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Magnetic Resonance Materials in Physics, Biology and Medicine","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s10334-024-01216-0","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

Abstract

Object: This study aimed to evaluate the relaxivity and uniformity of agarose gel phantoms added with relaxation modifiers. It is hypothesized that the modifiers could manipulate the T1 and T2 relaxations as well as the signal uniformity.

Materials and methods: Twenty agarose gel phantoms with different GdCl₃ and FeCl₃ volume fractions were prepared. The phantoms were scanned using a 3-T scanner implementing a turbo spin echo sequence to acquire T1 and T2 images. The SNR of the images were computed using Image-J software from 1, 3, and 25 regions-of-interest (ROIs) and were inverted as T1 and T2 curves.

Results: With the increase in relaxation modifier content, T1 SNR increased at a faster rate at very short TR and reached saturation at TR well below 400 ms. Agarose gel phantoms containing GdCl3 showed a higher saturation value as compared to phantoms containing FeCl3. For T2 SNR, differences between plots are observed at low TE. As TE gets larger, the SNR between plots is incomparable. The SNR for both groups was uniform among 1, 3, and 25 ROIs.

Discussions: It can be concluded that GdCl₃ and FeCl₃ solutions can be used as effective relaxation modifiers to reduce T1 but not T2 relaxation times.

求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
4.60
自引率
0.00%
发文量
58
审稿时长
>12 weeks
期刊介绍: MAGMA is a multidisciplinary international journal devoted to the publication of articles on all aspects of magnetic resonance techniques and their applications in medicine and biology. MAGMA currently publishes research papers, reviews, letters to the editor, and commentaries, six times a year. The subject areas covered by MAGMA include: advances in materials, hardware and software in magnetic resonance technology, new developments and results in research and practical applications of magnetic resonance imaging and spectroscopy related to biology and medicine, study of animal models and intact cells using magnetic resonance, reports of clinical trials on humans and clinical validation of magnetic resonance protocols.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信