Effect of chairside polishing systems on the surface roughness of different CAD-CAM denture base materials.

IF 4.3 2区 医学 Q1 DENTISTRY, ORAL SURGERY & MEDICINE
Nareudee Limpuangthip, Sarita Apiromwijit, Prarom Salimee
{"title":"Effect of chairside polishing systems on the surface roughness of different CAD-CAM denture base materials.","authors":"Nareudee Limpuangthip, Sarita Apiromwijit, Prarom Salimee","doi":"10.1016/j.prosdent.2024.11.011","DOIUrl":null,"url":null,"abstract":"<p><strong>Statement of problem: </strong>Adjusting and polishing a denture base affects surface roughness and, consequently, microbial adhesion. Since various computer-aided design and computer-aided manufacturing (CAD-CAM) denture base materials are available, the efficiency of chairside polishing systems to achieve a proper surface roughness should be investigated.</p><p><strong>Purpose: </strong>The purpose of this in vitro study was to compare the surface roughness of milled and 3-dimensional (3D) printed denture base materials with that of heat-polymerized acrylic resin after the use of 2 different chairside polishing systems.</p><p><strong>Material and methods: </strong>Heat-polymerized (control), milled, and 3D printed denture base materials were tested. Laboratory polished and unpolished denture bases served as positive and negative controls. Specimens were divided into 2 chairside silicone polishing systems (AcryPoint system and Exa technique). Surface roughness was measured before and after polishing. Surface morphology of the unpolished and polished specimens was observed via scanning electron microscopy. The surface hardness of unpolished specimens was measured using a Vickers hardness tester. Stress-strain behavior of the silicone matrix and abrasive filler size of each polisher was assessed. The effects of denture base materials and polishing systems on surface roughness and hardness were evaluated using 1-way, 2-way, and repeated measures analyses of variance (ANOVA) (α=.05), along with Weibull proportional hazards regression to assess the likelihood of achieving clinically acceptable surface roughness. The Spearman correlation assessed the relationship between the hardness of unpolished denture bases and final surface roughness.</p><p><strong>Results: </strong>The surface roughness of all denture bases decreased with increased polishing duration, reaching a plateau after 60 seconds. For the heat-polymerized and milled dentures, the Exa technique consistently yielded lower roughness than the AcryPoint system (P<.001). Conversely, both polishing systems produced comparable surface roughness on the 3D printed denture base. The Vickers hardness of the unpolished milled denture was significantly higher than of the others (P=.010). The stress-strain behavior of the polisher matrix revealed distinct characteristics between coarse or medium and fine polishers within each polishing system. The abrasive filler size of the AcryPoint coarse polisher was relatively larger than that of the Exa technique.</p><p><strong>Conclusions: </strong>Regardless of polishing protocols, the 3D printed denture base exhibited the highest surface roughness, followed by heat-polymerized and milled denture bases. The surface roughness of the polished denture was not related with the material hardness. For heat-polymerized and milled dentures, a chairside silicone polishing system can be used to attain a level of surface roughness similar to that of laboratory polishing, depending on the properties of the chairside silicone polishing system.</p><p><strong>Data availability statement: </strong>The data that support the findings of this study are available upon request from the corresponding author.</p>","PeriodicalId":16866,"journal":{"name":"Journal of Prosthetic Dentistry","volume":" ","pages":""},"PeriodicalIF":4.3000,"publicationDate":"2024-12-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Prosthetic Dentistry","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1016/j.prosdent.2024.11.011","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

Abstract

Statement of problem: Adjusting and polishing a denture base affects surface roughness and, consequently, microbial adhesion. Since various computer-aided design and computer-aided manufacturing (CAD-CAM) denture base materials are available, the efficiency of chairside polishing systems to achieve a proper surface roughness should be investigated.

Purpose: The purpose of this in vitro study was to compare the surface roughness of milled and 3-dimensional (3D) printed denture base materials with that of heat-polymerized acrylic resin after the use of 2 different chairside polishing systems.

Material and methods: Heat-polymerized (control), milled, and 3D printed denture base materials were tested. Laboratory polished and unpolished denture bases served as positive and negative controls. Specimens were divided into 2 chairside silicone polishing systems (AcryPoint system and Exa technique). Surface roughness was measured before and after polishing. Surface morphology of the unpolished and polished specimens was observed via scanning electron microscopy. The surface hardness of unpolished specimens was measured using a Vickers hardness tester. Stress-strain behavior of the silicone matrix and abrasive filler size of each polisher was assessed. The effects of denture base materials and polishing systems on surface roughness and hardness were evaluated using 1-way, 2-way, and repeated measures analyses of variance (ANOVA) (α=.05), along with Weibull proportional hazards regression to assess the likelihood of achieving clinically acceptable surface roughness. The Spearman correlation assessed the relationship between the hardness of unpolished denture bases and final surface roughness.

Results: The surface roughness of all denture bases decreased with increased polishing duration, reaching a plateau after 60 seconds. For the heat-polymerized and milled dentures, the Exa technique consistently yielded lower roughness than the AcryPoint system (P<.001). Conversely, both polishing systems produced comparable surface roughness on the 3D printed denture base. The Vickers hardness of the unpolished milled denture was significantly higher than of the others (P=.010). The stress-strain behavior of the polisher matrix revealed distinct characteristics between coarse or medium and fine polishers within each polishing system. The abrasive filler size of the AcryPoint coarse polisher was relatively larger than that of the Exa technique.

Conclusions: Regardless of polishing protocols, the 3D printed denture base exhibited the highest surface roughness, followed by heat-polymerized and milled denture bases. The surface roughness of the polished denture was not related with the material hardness. For heat-polymerized and milled dentures, a chairside silicone polishing system can be used to attain a level of surface roughness similar to that of laboratory polishing, depending on the properties of the chairside silicone polishing system.

Data availability statement: The data that support the findings of this study are available upon request from the corresponding author.

求助全文
约1分钟内获得全文 求助全文
来源期刊
Journal of Prosthetic Dentistry
Journal of Prosthetic Dentistry 医学-牙科与口腔外科
CiteScore
7.00
自引率
13.00%
发文量
599
审稿时长
69 days
期刊介绍: The Journal of Prosthetic Dentistry is the leading professional journal devoted exclusively to prosthetic and restorative dentistry. The Journal is the official publication for 24 leading U.S. international prosthodontic organizations. The monthly publication features timely, original peer-reviewed articles on the newest techniques, dental materials, and research findings. The Journal serves prosthodontists and dentists in advanced practice, and features color photos that illustrate many step-by-step procedures. The Journal of Prosthetic Dentistry is included in Index Medicus and CINAHL.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信