Reliability of 4D Flow MRI for Investigation of Fetal Cardiovascular Hemodynamics in the Third Trimester.

IF 3.8 Q1 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
Erin K Englund, Takashi Fujiwara, Sarah A Smith, Mariana L Meyers, Richard M Friesen, Lorna P Browne, Alex J Barker
{"title":"Reliability of 4D Flow MRI for Investigation of Fetal Cardiovascular Hemodynamics in the Third Trimester.","authors":"Erin K Englund, Takashi Fujiwara, Sarah A Smith, Mariana L Meyers, Richard M Friesen, Lorna P Browne, Alex J Barker","doi":"10.1148/ryct.240119","DOIUrl":null,"url":null,"abstract":"<p><p>Purpose To provide reference values for four-dimensional (4D) flow MRI in healthy fetuses and evaluate reliability of fetal 4D flow MRI hemodynamics in third trimester fetuses with normal cardiovascular development or suspected coarctation of the aorta (CoA). Materials and Methods Pregnant patients with healthy fetuses or fetuses with echocardiographic concern for CoA were prospectively recruited between May 2021 and October 2023. Doppler US-gated fetal 4D flow MRI was performed at 3 T. Repeated 4D flow (time permitting) and two-dimensional (2D) phase contrast (PC) MRI data were acquired. Net flow was quantified, and the reliability of 4D flow measurement was evaluated by using precision across adjacent measurement planes, internal consistency based on conservation of mass, comparison of net flow from 4D flow MRI versus 2D PC MRI, and repeatability of 4D flow from separate acquisitions. Results Data were obtained in 34 pregnant participants (mean maternal age, 33 years ± 5 [SD]; mean gestational age, 35 weeks ± 2; <i>n</i> = 22 healthy fetuses and 12 fetuses with suspected CoA). Precision was high across all vascular segments (mean within-subject coefficient of variation = 7%). For mass conservation, there was an average difference of 19% ± 12 between ductus arteriosus plus isthmus flow versus descending aorta flow (<i>r</i> = 0.76). Net flow measured with 4D flow MRI correlated with that measured with 2D PC MRI (<i>r</i> = 0.51) but was underestimated relative to 2D PC MRI by approximately 34%. Hemodynamic parameters quantified from repeated 4D flow acquisitions had good agreement, with an intraclass correlation coefficient of 0.94 between test and retest data. Conclusion Hemodynamic measurements derived from fetal 4D flow MRI were reliable, showing good internal consistency, precision, and repeatability; however, as expected, 4D flow MRI underestimated absolute blood flow relative to 2D PC MRI. <b>Keywords:</b> Fetal MRI, Cardiac, Aorta, Hemodynamics/Flow Dynamics, Pulmonary Arteries <i>Supplemental material is available for this article.</i> © RSNA, 2024.</p>","PeriodicalId":21168,"journal":{"name":"Radiology. Cardiothoracic imaging","volume":"6 6","pages":"e240119"},"PeriodicalIF":3.8000,"publicationDate":"2024-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Radiology. Cardiothoracic imaging","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1148/ryct.240119","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose To provide reference values for four-dimensional (4D) flow MRI in healthy fetuses and evaluate reliability of fetal 4D flow MRI hemodynamics in third trimester fetuses with normal cardiovascular development or suspected coarctation of the aorta (CoA). Materials and Methods Pregnant patients with healthy fetuses or fetuses with echocardiographic concern for CoA were prospectively recruited between May 2021 and October 2023. Doppler US-gated fetal 4D flow MRI was performed at 3 T. Repeated 4D flow (time permitting) and two-dimensional (2D) phase contrast (PC) MRI data were acquired. Net flow was quantified, and the reliability of 4D flow measurement was evaluated by using precision across adjacent measurement planes, internal consistency based on conservation of mass, comparison of net flow from 4D flow MRI versus 2D PC MRI, and repeatability of 4D flow from separate acquisitions. Results Data were obtained in 34 pregnant participants (mean maternal age, 33 years ± 5 [SD]; mean gestational age, 35 weeks ± 2; n = 22 healthy fetuses and 12 fetuses with suspected CoA). Precision was high across all vascular segments (mean within-subject coefficient of variation = 7%). For mass conservation, there was an average difference of 19% ± 12 between ductus arteriosus plus isthmus flow versus descending aorta flow (r = 0.76). Net flow measured with 4D flow MRI correlated with that measured with 2D PC MRI (r = 0.51) but was underestimated relative to 2D PC MRI by approximately 34%. Hemodynamic parameters quantified from repeated 4D flow acquisitions had good agreement, with an intraclass correlation coefficient of 0.94 between test and retest data. Conclusion Hemodynamic measurements derived from fetal 4D flow MRI were reliable, showing good internal consistency, precision, and repeatability; however, as expected, 4D flow MRI underestimated absolute blood flow relative to 2D PC MRI. Keywords: Fetal MRI, Cardiac, Aorta, Hemodynamics/Flow Dynamics, Pulmonary Arteries Supplemental material is available for this article. © RSNA, 2024.

求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
20.40
自引率
1.40%
发文量
0
期刊介绍:
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信