Preclinical validation of a metasurface-inspired conformal elliptical-cylinder resonator for wrist MRI at 1.5 T.

IF 2.1 4区 医学 Q2 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
Magnetic resonance imaging Pub Date : 2025-02-01 Epub Date: 2024-12-01 DOI:10.1016/j.mri.2024.110291
Yakui Wang, Zhonghai Chi, Yi Yi, Yingyi Qi, Xinxin Li, Qian Zhao, Zhuozhao Zheng
{"title":"Preclinical validation of a metasurface-inspired conformal elliptical-cylinder resonator for wrist MRI at 1.5 T.","authors":"Yakui Wang, Zhonghai Chi, Yi Yi, Yingyi Qi, Xinxin Li, Qian Zhao, Zhuozhao Zheng","doi":"10.1016/j.mri.2024.110291","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>To design a metasurface-inspired conformal elliptical-cylinder resonator (MICER) for wrist magnetic resonance imaging at 1.5 T and evaluate its potential for clinical applications.</p><p><strong>Methods: </strong>An electromagnetic simulation was used to characterize the effect of MICER on radio frequency fields. A phantom and 14 wrists from 7 healthy volunteers were examined using a 1.5 T MRI system. The examination included T1-weighted spin echo, fat-saturation proton density-weighted fast spin echo, and three-dimensional T1-weighted gradient echo sequences. All scans were repeated using two methods: MICER combined with the spinal coil, which is a surface coil built-in examination table, and the 12-channel wrist array coil, to receive signals. Image signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were calculated, and the differences between the two methods were compared using a paired Student's t-test.</p><p><strong>Results: </strong>In the phantom study, the image obtained with MICER had a higher SNR compared to the image obtained with the 12-channel wrist coil. Almost all wrist tissues showed a higher SNR on the images obtained with MICER than on the images obtained with the 12-channel wrist coil (P < 0.05). And the CNR between wrist tissues on images obtained with MICER was higher than that obtained with the 12-channel wrist coil (P < 0.05).</p><p><strong>Conclusions: </strong>The quality of the MRI using MICER is superior to that of the commercially available 12-channel wrist coil, indicating its potential value for clinical practice.</p>","PeriodicalId":18165,"journal":{"name":"Magnetic resonance imaging","volume":" ","pages":"110291"},"PeriodicalIF":2.1000,"publicationDate":"2025-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Magnetic resonance imaging","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1016/j.mri.2024.110291","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/12/1 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

Abstract

Objective: To design a metasurface-inspired conformal elliptical-cylinder resonator (MICER) for wrist magnetic resonance imaging at 1.5 T and evaluate its potential for clinical applications.

Methods: An electromagnetic simulation was used to characterize the effect of MICER on radio frequency fields. A phantom and 14 wrists from 7 healthy volunteers were examined using a 1.5 T MRI system. The examination included T1-weighted spin echo, fat-saturation proton density-weighted fast spin echo, and three-dimensional T1-weighted gradient echo sequences. All scans were repeated using two methods: MICER combined with the spinal coil, which is a surface coil built-in examination table, and the 12-channel wrist array coil, to receive signals. Image signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were calculated, and the differences between the two methods were compared using a paired Student's t-test.

Results: In the phantom study, the image obtained with MICER had a higher SNR compared to the image obtained with the 12-channel wrist coil. Almost all wrist tissues showed a higher SNR on the images obtained with MICER than on the images obtained with the 12-channel wrist coil (P < 0.05). And the CNR between wrist tissues on images obtained with MICER was higher than that obtained with the 12-channel wrist coil (P < 0.05).

Conclusions: The quality of the MRI using MICER is superior to that of the commercially available 12-channel wrist coil, indicating its potential value for clinical practice.

求助全文
约1分钟内获得全文 求助全文
来源期刊
Magnetic resonance imaging
Magnetic resonance imaging 医学-核医学
CiteScore
4.70
自引率
4.00%
发文量
194
审稿时长
83 days
期刊介绍: Magnetic Resonance Imaging (MRI) is the first international multidisciplinary journal encompassing physical, life, and clinical science investigations as they relate to the development and use of magnetic resonance imaging. MRI is dedicated to both basic research, technological innovation and applications, providing a single forum for communication among radiologists, physicists, chemists, biochemists, biologists, engineers, internists, pathologists, physiologists, computer scientists, and mathematicians.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信