CineECG Repolarization Gradients Predict Acute Hemodynamic Response in CRT Patients.

IF 2.3 3区 医学 Q2 CARDIAC & CARDIOVASCULAR SYSTEMS
Ksenia Sedova, Jan E Azarov, Peter M Van Dam, Lucie Necasova, Jan Kukla, Marek Sramko, Lukas Kryze, Josef Kautzner
{"title":"CineECG Repolarization Gradients Predict Acute Hemodynamic Response in CRT Patients.","authors":"Ksenia Sedova, Jan E Azarov, Peter M Van Dam, Lucie Necasova, Jan Kukla, Marek Sramko, Lukas Kryze, Josef Kautzner","doi":"10.1111/jce.16525","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>A variable proportion of non-responders to cardiac resynchronization therapy (CRT) warrants the search for new approaches to optimize the position of the left ventricular (LV) lead and the CRT device programming. CineECG is a novel ECG modality proposed for the spatial visualization and quantification of myocardial depolarization and repolarization sequences.</p><p><strong>Objective: </strong>The present study aimed to evaluate CineECG-derived parameters in different pacing modes and to test their associations with acute hemodynamic responses in CRT patients.</p><p><strong>Methods and results: </strong>CineECG was used to construct the average electrical path within the cardiac anatomy from the 12-lead ECG. CineECG and LV dP/dt max were tested in 15 patients with nonischemic dilated cardiomyopathy and left bundle branch block (QRS: 170 ± 17 ms; LVEF: 26 ± 5.5%) under pacing protocols with different LV lead localizations. The CineECG-derived path directions were computed for the QRS and ST-T intervals for the anteroposterior (X<sub>h</sub>), interventricular (Y<sub>h</sub>), and apicobasal (Z<sub>h</sub>) axes. In a multivariate linear regression analysis with adjustment for the pacing protocol type, the ST-T path direction Y<sub>h</sub> was independently associated with the increase in dP/dt max during CRT, [regression coefficient 639.4 (95% confidence interval: 187.9-1090.9), p = 0.006]. In ROC curve analysis, the ST-T path direction Y<sub>h</sub> was associated with the achievement of a 10% increase in dP/dt max (AUC: 0.779, p = 0.002) with the optimal cut-off > 0.084 (left-to-right direction) with sensitivity 0.67 and specificity 0.92.</p><p><strong>Conclusion: </strong>The acute hemodynamic response in CRT patients was associated with specific CineECG repolarization sequence parameters, warranting their further testing as potential predictors of clinical outcomes.</p>","PeriodicalId":15178,"journal":{"name":"Journal of Cardiovascular Electrophysiology","volume":" ","pages":""},"PeriodicalIF":2.3000,"publicationDate":"2024-12-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Cardiovascular Electrophysiology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1111/jce.16525","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0

Abstract

Introduction: A variable proportion of non-responders to cardiac resynchronization therapy (CRT) warrants the search for new approaches to optimize the position of the left ventricular (LV) lead and the CRT device programming. CineECG is a novel ECG modality proposed for the spatial visualization and quantification of myocardial depolarization and repolarization sequences.

Objective: The present study aimed to evaluate CineECG-derived parameters in different pacing modes and to test their associations with acute hemodynamic responses in CRT patients.

Methods and results: CineECG was used to construct the average electrical path within the cardiac anatomy from the 12-lead ECG. CineECG and LV dP/dt max were tested in 15 patients with nonischemic dilated cardiomyopathy and left bundle branch block (QRS: 170 ± 17 ms; LVEF: 26 ± 5.5%) under pacing protocols with different LV lead localizations. The CineECG-derived path directions were computed for the QRS and ST-T intervals for the anteroposterior (Xh), interventricular (Yh), and apicobasal (Zh) axes. In a multivariate linear regression analysis with adjustment for the pacing protocol type, the ST-T path direction Yh was independently associated with the increase in dP/dt max during CRT, [regression coefficient 639.4 (95% confidence interval: 187.9-1090.9), p = 0.006]. In ROC curve analysis, the ST-T path direction Yh was associated with the achievement of a 10% increase in dP/dt max (AUC: 0.779, p = 0.002) with the optimal cut-off > 0.084 (left-to-right direction) with sensitivity 0.67 and specificity 0.92.

Conclusion: The acute hemodynamic response in CRT patients was associated with specific CineECG repolarization sequence parameters, warranting their further testing as potential predictors of clinical outcomes.

CineECG复极化梯度预测CRT患者的急性血流动力学反应。
导论:心脏再同步化治疗(CRT)无反应的比例不同,需要寻找新的方法来优化左室(LV)导联的位置和CRT设备编程。CineECG是一种新的心电模式,用于心肌去极化和复极化序列的空间可视化和量化。目的:本研究旨在评估不同起搏模式下cineecg衍生参数,并测试其与CRT患者急性血流动力学反应的相关性。方法和结果:采用CineECG方法,从12导联心电图中构建心脏解剖内的平均电路径。对15例非缺血性扩张型心肌病合并左束支传导阻滞患者(QRS: 170±17 ms;不同左室导联定位起搏方案下LVEF: 26±5.5%)。计算正位轴(Xh)、室间轴(Yh)和顶基底轴(Zh)的QRS和ST-T间隔的cineecg衍生路径方向。在调整起搏方案类型的多元线性回归分析中,ST-T路径方向Yh与CRT期间dP/dt max的增加独立相关,[回归系数639.4(95%可信区间:187.9-1090.9),p = 0.006]。在ROC曲线分析中,ST-T路径方向Yh与dP/dt max增加10%相关(AUC: 0.779, p = 0.002),最佳截止点> 0.084(左至右方向),敏感性0.67,特异性0.92。结论:CRT患者的急性血流动力学反应与特定的CineECG复极序列参数相关,值得进一步检测作为临床结果的潜在预测因素。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
5.20
自引率
14.80%
发文量
433
审稿时长
3-6 weeks
期刊介绍: Journal of Cardiovascular Electrophysiology (JCE) keeps its readership well informed of the latest developments in the study and management of arrhythmic disorders. Edited by Bradley P. Knight, M.D., and a distinguished international editorial board, JCE is the leading journal devoted to the study of the electrophysiology of the heart.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信