M G Senocak, S Okur, U Ersoz, L E Yanmaz, Y Kocaman, F Turgut, A G Bedir, O T Orhun
{"title":"Comparison of human smartwatch and transmittance pulse oximetry for evaluating peripheral oxygen saturation in anesthetized dogs.","authors":"M G Senocak, S Okur, U Ersoz, L E Yanmaz, Y Kocaman, F Turgut, A G Bedir, O T Orhun","doi":"10.22099/IJVR.2024.47628.6884","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Pulse oximetry is a valuable tool for monitoring animals during anesthesia and assessing the adequacy of administered oxygen therapy.</p><p><strong>Aims: </strong>To compare the pulse oximeter readings obtained by the Garmin Fenix 5X plus (GF5Xp) smartwatch and transmittance pulse oximetry (TPO) in anesthetized dogs.</p><p><strong>Methods: </strong>Twelve clinical canine patients requiring anesthesia for castration were prospectively enrolled in this study. The animals were premedicated with intramuscular dexmedetomidine at a dose of 5 µg/kg. Anesthesia was induced through intravenous administration of propofol and maintained using sevoflurane. The arterial hemoglobin oxygen saturation (SpO<sub>2</sub>) readings obtained from the tongue using TPO (238 readings) were compared with measurements taken over the lateral side of the tibia using a GF5Xp smart wearable device (238 readings). This comparison was performed using a Bland-Altman plot, where the differences (%) between the methods were plotted against their mean SpO<sub>2</sub> (Gold standard - Device), and the limits of agreement were represented as the mean ± 1.96 times the standard deviation.</p><p><strong>Results: </strong>The SpO<sub>2</sub> levels in dogs were overestimated by the GF5Xp relative to the readings obtained by the TPO, with the bias of -0.3% (95% CI: -3.1%-2.5%).</p><p><strong>Conclusion: </strong>GF5Xp may be interchangeable with TPO in dogs. Further studies are required to validate the accuracy of the GF5Xp in non-anesthetized dogs or dogs outside the physiological range.</p>","PeriodicalId":14629,"journal":{"name":"Iranian journal of veterinary research","volume":"25 2","pages":"166-169"},"PeriodicalIF":0.8000,"publicationDate":"2024-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11608528/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Iranian journal of veterinary research","FirstCategoryId":"97","ListUrlMain":"https://doi.org/10.22099/IJVR.2024.47628.6884","RegionNum":4,"RegionCategory":"农林科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"VETERINARY SCIENCES","Score":null,"Total":0}
引用次数: 0
Abstract
Background: Pulse oximetry is a valuable tool for monitoring animals during anesthesia and assessing the adequacy of administered oxygen therapy.
Aims: To compare the pulse oximeter readings obtained by the Garmin Fenix 5X plus (GF5Xp) smartwatch and transmittance pulse oximetry (TPO) in anesthetized dogs.
Methods: Twelve clinical canine patients requiring anesthesia for castration were prospectively enrolled in this study. The animals were premedicated with intramuscular dexmedetomidine at a dose of 5 µg/kg. Anesthesia was induced through intravenous administration of propofol and maintained using sevoflurane. The arterial hemoglobin oxygen saturation (SpO2) readings obtained from the tongue using TPO (238 readings) were compared with measurements taken over the lateral side of the tibia using a GF5Xp smart wearable device (238 readings). This comparison was performed using a Bland-Altman plot, where the differences (%) between the methods were plotted against their mean SpO2 (Gold standard - Device), and the limits of agreement were represented as the mean ± 1.96 times the standard deviation.
Results: The SpO2 levels in dogs were overestimated by the GF5Xp relative to the readings obtained by the TPO, with the bias of -0.3% (95% CI: -3.1%-2.5%).
Conclusion: GF5Xp may be interchangeable with TPO in dogs. Further studies are required to validate the accuracy of the GF5Xp in non-anesthetized dogs or dogs outside the physiological range.
期刊介绍:
The Iranian Journal of Veterinary Research(IJVR) is published quarterly in 4 issues. The aims of this journal are to improve and expand knowledge in all veterinary fields. It is an international journal indexed by the Thomson Institute for Scientific Information (ISI), Elsevier, Scopus, CAB International, Veterinary Bulletin and several other international databases. Research papers and reports on a wide range of veterinary topics are published in the journal after being evaluated by expert reviewers.The Editor-in-Chief is responsible for the editorial content of the journal—including peer-reviewed manuscripts—and the timing of its publication.