{"title":"Outcomes of device extraction in patients with chronic kidney disease on renal replacement therapy and cardiac implantable electronic devicead infections.","authors":"Ashraf Alzahrani, Lillie Lamont, Mohammed Mhanna, Peter Farjo, E Michael Powers, Steven Bailin, Paari Dominic","doi":"10.1016/j.hrthm.2024.11.052","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Patients with chronic kidney disease (CKD) on renal replacement therapy (RRT) are at high risk for cardiovascular implantable electronic device (CIED) infections. Although device extraction is standard management, it is often avoided in these patients because of high procedural risks.</p><p><strong>Objectives: </strong>Evaluate the outcomes of CIED extraction in CKD on RRT patients with device infection.</p><p><strong>Methods: </strong>This study used data from the TriNetX research network. The International Classification of Diseases-10<sup>th</sup> Revision-Clinical Modification coding system was used to identify patients. Adults with a history of CKD on RRT and CIED infection were included. Patients with renal transplantation and prosthetic heart valves were excluded. Patients were stratified by device extraction. The primary outcome was mortality at 1 year.</p><p><strong>Results: </strong>A total of 530 patients were identified, of whom 30% (n = 159) underwent device extraction. After propensity score matching (PSM), 302 patients remained, with 151 in each group. Kaplan-Meier survival analysis demonstrated a significant 1-year survival benefit for patients in the device extraction group (59.2%) compared with the no-extraction group (48.8%, P = .043; hazard ratio [HR], 0.696; 95% confidence interval [CI], 0.489-0.991). Freedom from complications such as pericardial effusion was similar between groups. Sensitivity analysis using Cox proportional hazards, adjusted for baseline confounders, confirmed the survival benefit of extraction, with a reduced mortality risk (HR, 0.581; 95% CI, 0.382-0.883; P = .011).</p><p><strong>Conclusion: </strong>In CKD on RRT patients with CIED infection, device extraction is associated with a reduction in all-cause mortality at 1 year. However, the rate of device extraction is low in this group.</p>","PeriodicalId":12886,"journal":{"name":"Heart rhythm","volume":" ","pages":""},"PeriodicalIF":5.6000,"publicationDate":"2024-11-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Heart rhythm","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1016/j.hrthm.2024.11.052","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0
Abstract
Background: Patients with chronic kidney disease (CKD) on renal replacement therapy (RRT) are at high risk for cardiovascular implantable electronic device (CIED) infections. Although device extraction is standard management, it is often avoided in these patients because of high procedural risks.
Objectives: Evaluate the outcomes of CIED extraction in CKD on RRT patients with device infection.
Methods: This study used data from the TriNetX research network. The International Classification of Diseases-10th Revision-Clinical Modification coding system was used to identify patients. Adults with a history of CKD on RRT and CIED infection were included. Patients with renal transplantation and prosthetic heart valves were excluded. Patients were stratified by device extraction. The primary outcome was mortality at 1 year.
Results: A total of 530 patients were identified, of whom 30% (n = 159) underwent device extraction. After propensity score matching (PSM), 302 patients remained, with 151 in each group. Kaplan-Meier survival analysis demonstrated a significant 1-year survival benefit for patients in the device extraction group (59.2%) compared with the no-extraction group (48.8%, P = .043; hazard ratio [HR], 0.696; 95% confidence interval [CI], 0.489-0.991). Freedom from complications such as pericardial effusion was similar between groups. Sensitivity analysis using Cox proportional hazards, adjusted for baseline confounders, confirmed the survival benefit of extraction, with a reduced mortality risk (HR, 0.581; 95% CI, 0.382-0.883; P = .011).
Conclusion: In CKD on RRT patients with CIED infection, device extraction is associated with a reduction in all-cause mortality at 1 year. However, the rate of device extraction is low in this group.
期刊介绍:
HeartRhythm, the official Journal of the Heart Rhythm Society and the Cardiac Electrophysiology Society, is a unique journal for fundamental discovery and clinical applicability.
HeartRhythm integrates the entire cardiac electrophysiology (EP) community from basic and clinical academic researchers, private practitioners, engineers, allied professionals, industry, and trainees, all of whom are vital and interdependent members of our EP community.
The Heart Rhythm Society is the international leader in science, education, and advocacy for cardiac arrhythmia professionals and patients, and the primary information resource on heart rhythm disorders. Its mission is to improve the care of patients by promoting research, education, and optimal health care policies and standards.